Tools for quantitative and validated measurements of cells.

In this chapter, we describe the preparation of thin films of collagen that can serve as reference materials for assuring reproducible and predictable cell responses. Subtle differences in the molecular-scale characteristics of extracellular matrix proteins, including the supramolecular structure of type 1 collagen, can have tremendous influences on cell state and cell-signaling pathways; therefore the careful control and analysis of the culture surface is critical to assure a relevant and consistent response in cell-based assays. We also describe how cell-phenotypic parameters such as morphology, proliferation, and green fluorescent protein expression can be unambiguously quantified in adherent cells by automated fluorescence microscopy or high content screening. Careful consideration of protocols, and the use of fluorescent reference materials, are essential to assure day-to-day and instrument-to-instrument interoperability. The ability to collect quantitative data on large numbers of cells in homogeneous matrix environments allows assessment of the range of phenotypes that are reproducibly expressed in clonal cell populations. The inherent distribution of responses in a cell population will determine how many cells must be measured to reach an accurate determination of cellular response.

Animals↗

The effect of surface chemistry on the formation of thin films of native fibrillar collagen.

In this study, we used well-defined, homogeneous, gradient and patterned substrates to explore the effects of surface chemistry on the supramolecular structure of adsorbed type I collagen. Type I collagen (320microg/mL) was allowed to adsorb onto self-assembled CH(3)-, COOH-, NH(2)- and OH-terminated alkylthiolate monolayers at 37 degrees C. Atomic force microscopy, ellipsometry and phase microscopy indicated that large supramolecular collagen fibril structures (approximately 200nm in diameter, several microns long) assembled only at the hydrophobic CH(3)-terminated surfaces. By varying the surface energy using a mixture of OH- and CH(3)-terminated thiols during monolayer formation, we found that large fibril assembly occurred at surfaces with a water contact angle above 83 degrees , but not on surfaces with a water contact angle below 63 degrees . Examining a surface with a linear hydrophobicity gradient revealed that the assembly of large collagen fibrils requires a hydrophobic surface with a water contact angle of at least 78 degrees . Collagen fibril density increased over a narrow range of surface energy and reached near-maximum density on surfaces with a water contact angle of 87 degrees . These studies confirm that the supramolecular structure of adsorbed collagen is highly dependent on the underlying substrate surface chemistry. We can take advantage of this dependency to pattern areas of fibrillar and non-fibrillar collagen on a single surface. Morphology studies with vascular smooth muscle cells indicated that only collagen films formed on hydrophobic substrates mimicked the biological properties of fibrillar collagen gels.

Adsorption↗

Combinatorial characterization of cell interactions with polymer surfaces.

We report a novel combinatorial methodology for characterizing the effects of polymer surface features on cell function. Libraries containing hundreds to thousands of distinct chemistries, microstructures, and roughnesses are prepared using composition spread and temperature gradient techniques. The method enables orders of magnitude increases in discovery rate, decreases variance, and allows for the first time high-throughput assays of cell response to physical and chemical surface features. The technique overcomes complex variable spaces that limit development of biomaterial surfaces for control of cell function. This report demonstrates these advantages by investigating the sensitivity of osteoblasts to the chemistry, microstructure, and roughness of poly(D,L-lactide) and poly(epsilon-caprolactone) blends. In particular, we use the phenomenon of heat-induced phase separation in these polymer mixtures to generate libraries with diverse surface features, followed by culture of UMR-106 and MC3T3-E1 osteoblasts on the libraries. Surface features produced at a specific composition and process temperature range were discovered to enhance dramatically alkaline phosphatase expression in both cell lines, not previously observed for osteoblasts on polymer blends.

3T3 Cells↗

Comparison of reagents for shape analysis of fixed cells by automated fluorescence microscopy.

BACKGROUND: Cell size and shape have been implicated as potentiators of intracellular signaling events and as indicators of abnormal cell behavior. Automated microscopy and image analysis can provide quantitative information about the size and shape of cultured cells, but it requires that the edge of a cell be clearly identified. Generating adequate contrast at the edge of thin well-spread cells can be challenging. METHODS: We compared six (five chemically reactive and one lipophilic) fluorescent molecules--5-chloromethyl fluorescein diacetate (CMFDA, CellTracker green), fluorescein-5-maleimide, fluorescein-5-isothiocyanate (FITC), 5-iodoacetamidofluorescein, 5(6)-carboxy fluorescein-N-hydroxysuccinimidyl ester, and N-fluorescein-1,2-dihexadecanoyl-sn-glycerol-3-phosphoethanolamine--for their effectiveness as stains for automated morphology analysis of fixed cells. RESULTS: Formaldehyde-fixed rat aortic smooth muscle cells stained with fluorescein-5-maleimide or FITC exhibited an average intensity that was at least twofold greater than cells stained with CMFDA even when subjected to a 25-fold shorter exposure time. Cell area determined with the higher intensity stains was less sensitive to threshold settings during automated cell morphology analysis. CONCLUSION: A procedure that includes the use of fluorescein-5-maleimide or FITC for staining fixed cell provides sensitivity sufficient to permit rapid, automated, morphologic analysis of well-spread fixed cells.

Animals↗

Co-extrusion of biocompatible polymers for scaffolds with co-continuous morphology.

A methodology for the preparation of porous scaffolds for tissue engineering using co-extrusion is presented. Poly(epsilon-caprolactone) is blended with poly(ethylene oxide) in a twinscrew extruder to form a two-phase material with micron-sized domains. Selective dissolution of the poly(ethylene oxide) with water results in a porous material. A range of blend volume fractions results in co-continuous networks of polymer and void spaces. Annealing studies demonstrate that the characteristic pore size may be increased to larger than 100 microm. The mechanical properties of the scaffolds are characterized by a compressive modulus on the order of 1 MPa at low strains but displaying a marked strain-dependence. The results of osteoblast seeding suggest it is possible to use co-extrusion to prepare polymer scaffolds without the introduction of toxic contaminants. Polymer co-extrusion is amenable to both laboratory- and industrial-scale production of scaffolds for tissue engineering and only requires rheological characterization of the blend components. This method leads to scaffolds that have continuous void space and controlled characteristic length scales without the use of potentially toxic organic solvents.

Algorithms↗