PubMed Health⌕ Search

Biomedical subjects

Alexander Ghanem

Publications and source records attributed to Alexander Ghanem.

7 recordsLinked to original sources

Cardiac morphogenetic defects and conduction abnormalities in mice homozygously deficient for connexin40 and heterozygously deficient for connexin45.

Connexin40 (Cx40) and connexin45 (Cx45) are involved in both cardiac morphogenesis and propagation of electrical activity. We found that Cx40/Cx45 double deficiency (Cx40(-/-)/Cx45(+/-)) causes a variety of cardiac defects leading to high mortality during embryonic development and at birth. The majority of Cx40(-/-)/Cx45(+/-) embryos and postnatal mice suffered from atrioventricular septal defects. Additional cardiac abnormalities, e.g., ventricular septal defects and abnormal myocardial arrangement, occurred at lower abundance. Electrocardiograms of Cx40(-/-)/Cx45(+/+) and Cx40(-/-)/Cx45(+/-) mice revealed prolongation of P-wave, PQ interval and QRS duration compared to controls. Interestingly, in Cx40(-/-)/Cx45(+/-) mice, PQ interval and QRS duration were significantly prolonged compared to Cx40(-/-)/Cx45(+/+) mice. We conclude that the gap junctional proteins Cx40 and Cx45 have overlapping and partially compensatory functions with regard to heart morphogenesis and cardiac conduction. Cx45 might be one of the genetic modifiers that can cause variations in the phenotype of connexin40-deficient animals. Our findings may be particularly relevant for understanding molecular factors contributing to human congenital cardiac diseases.

Animals↗

Connexin30.2 containing gap junction channels decelerate impulse propagation through the atrioventricular node.

In the mammalian heart, gap junction channels between electrically coupled cardiomyocytes are necessary for impulse propagation and coordinated contraction of atria and ventricles. Recently, mouse connexin30.2 (Cx30.2) was shown to be expressed in the cardiac conduction system, predominantly in sinoatrial and atrioventricular (AV) nodes. The corresponding gap junctional channels expressed in HeLa cells exhibit the lowest unitary conductance (9 pS) of all connexin channels. Here we report that Cx30.2 slows down the propagation of excitation through the AV node. Mice expressing a LacZ reporter gene instead of the Cx30.2 coding region (Cx30.2(LacZ/LacZ)) exhibit a PQ interval that is approximately 25% shorter than in WT littermates. By recording atrial, His, and ventricular signals with intracardiac electrodes, we show that this decrease is attributed to significantly accelerated conduction above the His bundle (atrial-His interval: 27.9 +/- 5.1 ms in Cx30.2(LacZ/LacZ) versus 37.1 +/- 4.1 ms in Cx30.2(+/+) mice), whereas HV conduction is unaltered. Atrial stimulation revealed an elevated AV-nodal conduction capacity and faster ventricular response rates during induced episodes of atrial fibrillation in Cx30.2(LacZ/LacZ) mice. Our results show that Cx30.2 contributes to the slowdown of impulse propagation in the AV node and additionally limits the maximum number of beats conducted from atria to ventricles. Thus, it is likely to be involved in coordination of atrial and ventricular contraction and to fulfill a protective role toward pathophysiological states such as atrial tachyarrhythmias (e.g., atrial fibrillation) by preventing rapid conduction to the ventricles potentially associated with hemodynamic deterioration.

Animals↗

Connexin31 cannot functionally replace connexin43 during cardiac morphogenesis in mice.

In the gastrulating mouse embryo, the gap junction protein connexin43 is expressed exclusively in cells derived from the inner cell mass, whereas connexin31 is expressed in cells of the trophoblast lineage. Since connexin43 and connexin31 do not form heterotypic gap junction channels in exogenous expression systems, such as HeLa cells and Xenopus oocytes, previous studies have suggested that the incompatibility of these two connexins could contribute to the separation of connexin43-expressing and connexin31-expressing compartments between embryo and extraembryonic tissues at gastrulation, respectively. Thus, we have generated connexin43 knock-in connexin31 mice, in which the coding region of the connexin43 gene was replaced by that of connexin31. Interbreeding of heterozygous connexin43 knock-in connexin31 mice resulted in homozygous connexin43 knock-in connexin31 mice, but none of them survived to adulthood. As these mice were born at the expected Mendelian frequency, we conclude that the reported incompatibility of connexin43 and connexin31 to form heterotypic gap junction channels does not interfere with normal embryonic development. Neonatal homozygous connexin43 knock-in connexin31 hearts showed malformation in the subpulmonary outlet of the right ventricle, similar to general connexin43-deficient mice. Electrocardiograms of neonatal hearts in homozygous connexin43 knock-in connexin31 mice revealed significantly low voltage of the QRS complex. This is in contrast to previous results from our laboratory which showed that replacement of connexin43 by connexin40 resulted in morphologically and functionally normal hearts. We conclude that connexin31 cannot functionally replace connexin43 during cardiac morphogenesis.

Animals↗

Echocardiographic assessment of left ventricular mass in neonatal and adult mice: accuracy of different echocardiographic methods.

Echocardiography is an established method to estimate left-ventricular mass (LVM) in mice. Accuracy is determined by cardiac size and morphology and influenced by mathematical models. We investigated accuracy of three common algorithms in three early developmental stages. High-resolution echocardiography was performed in 35 C57/BL6-mice. Therefore, two-dimensional-guided M-mode echocardiography and parasternal short- and long-axis views in B-mode were obtained. LVM was assessed in vivo applying Penn (P), Area Length (AL), and Truncated Ellipsoid (TE) algorithms and validated with histomorphometry. Regression analysis of all mice showed fair estimation of LVM assessed with M-mode-based Penn algorithm (y = 0.6*x - 0.12, r: 0.71). In contrast two-dimensional assessment of LVM revealed close linear relationship with histomorphometry (y(AL)= 1.21*x - 12.1, r: 0.88, y(TE)= 1.38*x - 2.88, r: 0.86). Bias was lowest for LVM-AL at diastole underestimating 3.2%. In concordance with the summarized data, LVM-P revealed lower regression coefficients and significant underestimation in all three subgroups. Small hearts (<50 mg, n = 12) correlated best with LVM-AL at systole. Hearts of adolescent (50-75 mg, n = 13) and adult (75-100 mg, n = 10) mice revealed close linear relationship with LVM-AL and LVM-TE at diastole. Echocardiographic assessment of LVM is feasible in hearts weighting less than 50 mg and can be estimated best in systole. Hearts weighting more than 50 mg are estimated most accurately by means of LVM-AL at diastole.

Algorithms↗

Defective epidermal barrier in neonatal mice lacking the C-terminal region of connexin43.

More than 97% of mice in which the C-terminal region of connexin43 (Cx43) was removed (designated as Cx43K258stop) die shortly after birth due to a defect of the epidermal barrier. The abnormal expression of Cx43K258stop protein in the uppermost layers of the epidermis seems to perturb terminal differentiation of keratinocytes. In contrast to Cx43-deficient mice, neonatal Cx43K258stop hearts show no lethal obstruction of the right ventricular outflow tract, but signs of dilatation. Electrocardiographies of neonatal hearts reveal repolarization abnormalities in 20% of homozygous Cx43K258stop animals. The very rare adult Cx43K258stop mice show a compensation of the epidermal barrier defect but persisting impairment of cardiac function in echocardiography. Female Cx43K258stop mice are infertile due to impaired folliculogenesis. Our results indicate that the C-terminally truncated Cx43K258stop mice lack essential functions of Cx43, although the truncated Cx43 protein can form open gap junctional channels.

Animals↗

In vitro and in vivo studies on continuous echo-contrast application strategies using SonoVue in a newly developed rotating pump setup.

With emerging imaging strategies for contrast sonography (CS), there is a rising demand for the precise control of ultrasound (US) contrast agent delivery. Constant delivery minimizes artefacts and improves efficacy. The aim of this study was to evaluate the physical properties of the new contrast agent SonoVue and to evaluate the feasibility and accuracy of a new infusion approach using an automated infusion system for contrast agitation and delivery of echo-contrast agents. In vitro testing of infusion properties of SonoVue were performed in a capillary phantom mimicking tissue perfusion. Nonagitated standard infusion setups were compared with hand agitation and the new pump system with respect to possible artefacts, constancy of contrast effect and efficacy. In three volunteers, the new pump system was tested for constancy of contrast in large vessels. Without continuous agitation, continuous infusion of SonoVue resulted in bolus-like signal-intensity curves, along with substantial imaging artefacts. Additionally, homogenization of SonoVue significantly improved efficacy (p < 0.0001). No significant differences were found between hand agitation and homogenization by the new pump. In clinical settings, constant agitation using the new pump resulted in constant signal conditions in the carotid artery 3.72 +/- 0.46 units (U) after 5 min. Continuous agitation of SonoVue is mandatory for quantitative approaches. By the new infusion technique, CS could be performed for a reasonably long time period and efficacy is significantly improved (p < 0.0001). The new infusion technique might thereby allow routine application of constant infusion scenarios in clinical CS.

Capillaries↗

Increasing myocardial contraction and blood pressure in C57BL/6 mice during early postnatal development.

Knowledge of the developmental changes of cardiovascular parameters in the genetic background of a mouse strain is important for understanding phenotypic changes in transgenic or knockout mouse models for heart disease. We studied arterial blood pressure and myocardial contractility in mice of the common background strain C57BL/6, aged 21 days [postnatal day 21 (P21)] to 580 days. Heart rate increased during maturation from 396 beats/min at P21 to 551 beats/min at postnatal day 50 (P50), and mean arterial blood pressure increased in parallel from 86 to 110 mmHg and remained constant afterward. Echocardiographically determined left ventricular myocardial wall dimensions (R = 0.79, P < 0.0001) and left ventricular mass calculated using the area-length algorithm correlated strongly with histomorphometrical measurements (R = 0.93, P < 0.001). Sarcomere shortening records from isolated ventricular myocytes used as a measure for myocardial contractility revealed a negative shortening-frequency relation under a pacing frequency of 2 Hz and a positive relation above 2 Hz. Shortening amplitudes recorded from P21 myocytes were smaller, and the shortening-frequency relation was less steep than in adult myocytes. A stimulation pause was followed by a negative "staircase" at pacing frequency of < or =6 Hz and a positive staircase at > or =6 Hz. P21 myocytes developed positive staircases at 8 and 10 Hz, and adult myocytes also developed them at 6 Hz. Blood pressure increase during maturation until P50 may originate from increasing single cardiomyocyte contractility.

Aging↗