Normal and pathological NCAT image and phantom data based on physiologically realistic left ventricle finite-element models.

The four-dimensional (4-D) NURBS-based cardiac-torso (NCAT) phantom, which provides a realistic model of the normal human anatomy and cardiac and respiratory motions, is used in medical imaging research to evaluate and improve imaging devices and techniques, especially dynamic cardiac applications. One limitation of the phantom is that it lacks the ability to accurately simulate altered functions of the heart that result from cardiac pathologies such as coronary artery disease (CAD). The goal of this work was to enhance the 4-D NCAT phantom by incorporating a physiologically based, finite-element (FE) mechanical model of the left ventricle (LV) to simulate both normal and abnormal cardiac motions. The geometry of the FE mechanical model was based on gated high-resolution X-ray multislice computed tomography (MSCT) data of a healthy male subject. The myocardial wall was represented as a transversely isotropic hyperelastic material, with the fiber angle varying from -90 degrees at the epicardial surface, through 0 degrees at the midwall, to 90 degrees at the endocardial surface. A time-varying elastance model was used to simulate fiber contraction, and physiological intraventricular systolic pressure-time curves were applied to simulate the cardiac motion over the entire cardiac cycle. To demonstrate the ability of the FE mechanical model to accurately simulate the normal cardiac motion as well as the abnormal motions indicative of CAD, a normal case and two pathologic cases were simulated and analyzed. In the first pathologic model, a subendocardial anterior ischemic region was defined. A second model was created with a transmural ischemic region defined in the same location. The FE-based deformations were incorporated into the 4-D NCAT cardiac model through the control points that define the cardiac structures in the phantom which were set to move according to the predictions of the mechanical model. A simulation study was performed using the FE-NCAT combination to investigate how the differences in contractile function between the subendocardial and transmural infarcts manifest themselves in myocardial Single photon emission computed tomography (SPECT) images. The normal FE model produced strain distributions that were consistent with those reported in the literature and a motion consistent with that defined in the normal 4-D NCAT beating heart model based on tagged magnetic resonance imaging (MRI) data. The addition of a subendocardial ischemic region changed the average transmural circumferential strain from a contractile value of -0.09 to a tensile value of 0.02. The addition of a transmural ischemic region changed average circumferential strain to a value of 0.13, which is consistent with data reported in the literature. Model results demonstrated differences in contractile function between subendocardial and transmural infarcts and how these differences in function are documented in simulated myocardial SPECT images produced using the 4-D NCAT phantom. Compared with the original NCAT beating heart model, the FE mechanical model produced a more accurate simulation for the cardiac motion abnormalities. Such a model, when incorporated into the 4-D NCAT phantom, has great potential for use in cardiac imaging research. With its enhanced physiologically based cardiac model, the 4-D NCAT phantom can be used to simulate realistic, predictive imaging data of a patient population with varying whole-body anatomy and with varying healthy and diseased states of the heart that will provide a known truth from which to evaluate and improve existing and emerging 4-D imaging techniques used in the diagnosis of cardiac disease.

Algorithms↗

Measurement of strain in the left ventricle during diastole with cine-MRI and deformable image registration.

The assessment of regional heart wall motion (local strain) can localize ischemic myocardial disease, evaluate myocardial viability, and identify impaired cardiac function due to hypertrophic or dilated cardiomyopathies. The objectives of this research were to develop and validate a technique known as hyperelastic warping for the measurement of local strains in the left ventricle from clinical cine-magnetic resonance imaging (MRI) image datasets. The technique uses differences in image intensities between template (reference) and target (loaded) image datasets to generate a body force that deforms a finite element (FE) representation of the template so that it registers with the target image. To validate the technique, MRI image datasets representing two deformation states of a left ventricle were created such that the deformation map between the states represented in the images was known. A beginning diastolic cine-MRI image dataset from a normal human subject was defined as the template. A second image dataset (target) was created by mapping the template image using the deformation results obtained from a forward FE model of diastolic filling. Fiber stretch and strain predictions from hyperelastic warping showed good agreement with those of the forward solution (R2=0.67 stretch, R2=0.76 circumferential strain, R2=0.75 radial strain, and R2=0.70 in-plane shear). The technique had low sensitivity to changes in material parameters (deltaR2= -0.023 fiber stretch, deltaR2=-0.020 circumferential strain, deltaR2=-0.005 radial strain, and deltaR2=0.0125 shear strain with little or no change in rms error), with the exception of changes in bulk modulus of the material. The use of an isotropic hyperelastic constitutive model in the warping analyses degraded the predictions of fiber stretch. Results were unaffected by simulated noise down to a signal-to-noise ratio (SNR) of 4.0 (deltaR2= -0.032 fiber stretch, deltaR2=-0.023 circumferential strain, deltaR2=-0.04 radial strain, and deltaAR2=0.0211 shear strain with little or no increase in rms error). This study demonstrates that warping in conjunction with cine-MRI imaging can be used to determine local ventricular strains during diastole.

Diastole↗

Strain measurement in coronary arteries using intravascular ultrasound and deformable images.

Atherosclerotic plaque rupture is responsible for the majority of myocardial infarctions and acute coronary syndromes. Rupture is initiated by mechanical failure of the plaque cap, and thus study of the deformation of the plaque in the artery can elucidate the events that lead to myocardial infarction. Intravascular ultrasound (IVUS) provides high resolution in vitro and in vivo cross-sectional images of blood vessels. To extract the deformation field from sequences of IVUS images, a registration process must be performed to correlate material points between image pairs. The objective of this study was to determine the efficacy of an image registration technique termed Warping to determine strains in plaques and coronary arteries from paired IVUS images representing two different states of deformation. The Warping technique uses pointwise differences in pixel intensities between image pairs to generate a distributed body force that acts to deform a finite element model. The strain distribution estimated by image-based Warping showed excellent agreement with a known forward finite element solution, representing the gold standard, from which the displaced image was created. The Warping technique had a low sensitivity to changes in material parameters or material model and had a low dependency on the noise present in the images. The Warping analysis was also able to produce accurate strain distributions when the constitutive model used for the Warping analysis and the forward analysis was different. The results of this study demonstrate that Warping in conjunction with in vivo IVUS imaging will determine the change in the strain distribution resulting from physiological loading and may be useful as a diagnostic tool for predicting the likelihood of plaque rupture through the determination of the relative stiffness of the plaque constituents.

Algorithms↗