PubMed Health⌕ Search

Biomedical subjects

Alexander Katsevich

Publications and source records attributed to Alexander Katsevich.

6 recordsLinked to original sources

Formulation of four Katsevich algorithms in native geometry.

We derive formulations of the four exact helical Katsevich algorithms in the native cylindrical detector geometry, which allow efficient implementation in modern computed tomography scanners with wide cone beam aperture. Also, we discuss some aspects of numerical implementation.

Algorithms↗

Image reconstruction for the circle-and-arc trajectory.

Proposed is an exact shift-invariant filtered backprojection algorithm for the circle-and-arc trajectory. The algorithm has several important features. First, it allows for the circle to be incomplete. Second, axial truncation of the cone beam data is allowed. Third, the length of the arc is determined only by the region of interest and is independent of the size of the entire object. The algorithm is quite flexible and can be used for even more general trajectories that consist of several circular segments and arcs. The algorithm applies also in the case when the circle (or, circles) is complete. A numerical experiment with the clock phantom demonstrated good image quality.

Algorithms↗

Image reconstruction for the circle and line trajectory.

We propose an exact shift-invariant filtered backprojection algorithm for inversion of the cone beam data in the case when the source trajectory consists of an incomplete circle and a line segment. The algorithm allows for axial truncation of the cone beam data. The length of the line scan is determined only by the region of interest and is independent of the size of the entire object. The algorithm is quite flexible and can also be used for more general trajectories consisting of several (complete or incomplete) circles and line segments. Results of numerical experiments demonstrate good image quality.

Algorithms↗

Exact filtered backprojection reconstruction for dynamic pitch helical cone beam computed tomography.

We present an exact filtered backprojection reconstruction formula for helical cone beam computed tomography in which the pitch of the helix varies with time. We prove that the resulting algorithm, which is functionally identical to the constant pitch case, provides exact reconstruction provided that the projection of the helix onto the detector forms convex boundaries and that PI lines are unique. Furthermore, we demonstrate that both of these conditions are satisfied provided the sum of the translational velocity and the derivative of the translational acceleration does not change sign. As a special case, we show that gantry tilt can also be handled by our dynamic pitch formula. Simulation results demonstrate the resulting algorithm.

Algorithms↗

On two versions of a 3-pi algorithm for spiral CT.

A 3pi algorithm is obtained in which all the derivatives are confined to a detector array. Distance weighting of backprojection coefficients of the algorithm is studied. A numerical experiment indicates that avoiding differentiation along the source trajectory improves spatial resolution. Another numerical experiment shows that the terms depending on the non-standard distance weighting l/[x - y (s)] can no longer be ignored.

Algorithms↗

Analysis of an exact inversion algorithm for spiral cone-beam CT.

In this paper we continue studying a theoretically exact filtered backprojection inversion formula for cone beam spiral CT proposed earlier by the author. Our results show that if the phantom f is constant along the axial direction, the formula is equivalent to the 2D Radon transform inversion. Also, the inversion formula remains exact as spiral pitch goes to zero and in the limit becomes again the 2D Radon transform inversion formula. Finally, we show that according to the formula the processed cone beam projections should be backprojected using both the inverse distance squared law and the inverse distance law.

Algorithms↗