PubMed Health⌕ Search

Biomedical subjects

Alexander Pfeil

Publications and source records attributed to Alexander Pfeil.

6 recordsLinked to original sources

The potential of digital X-ray radiogrammetry (DXR) in the assessment of osteopenia in children with chronic inflammatory bowel disease.

BACKGROUND: Loss of bone mass is a known complication of chronic inflammatory bowel disease (IBD) in children. The gold standard in the evaluation of bone mineral density (BMD) is dual energy X-ray absorptiometry (DXA). OBJECTIVE: In this preliminary study we evaluated digital X-ray radiogrammetry (DXR) which estimates BMD (DXR-BMD) from hand radiographs in children with IBD. MATERIALS AND METHODS: A total of 26 children with IBD (10 girls, 16 boys; age range 10-18 years) underwent DXR for the calculation of DXR-BMD and metacarpal index (DXR-MCI) using the Pronosco X-posure system. The results were compared with a local reference database and correlated with the results of DXA. RESULTS: DXR-BMD was 0.36-0.56 g/cm(2) (median 0.46 g/cm(2)) in Crohn disease patients and 0.38-0.63 g/cm(2) (median 0.48 g/cm(2)) in ulcerative colitis patients. DXR-MCI was 0.29-0.49 in Crohn disease patients and 0.28-0.53 in ulcerative colitis patients. The Z-scores were reduced to <-1 SD in five Crohn disease patients and in six ulcerative colitis patients. The coefficients (r) for the correlations between DXR-BMD and DXA-BMD were 0.78 for the lumbar spine and 0.61 for the proximal femur (P<0.01), and between DXR-MCI and DXA-BMD were 0.78 for the lumbar spine and 0.51 for the proximal femur (P<0.01). CONCLUSIONS: DXR seems to be able to estimate cortical osteopenia in children with chronic IBD. The DXR results showed a positive correlation with DXA results.

Absorptiometry, Photon↗

Computerized digital imaging techniques provided by digital X-ray radiogrammetry as new diagnostic tool in rheumatoid arthritis.

PURPOSE: Our study evaluates digital x-ray radiogrammetry (DXR) and Radiogrammetry Kit (RK) as a new diagnostic method for the measurement of disease-related osteoporosis including quantification of joint space narrowing dependent on the severity of rheumatoid arthritis (RA). MATERIALS AND METHODS: A total of 172 unselected patients with RA underwent computerized measurements of bone mineral density (BMD) and metacarpal index (MCI) by DXR, as well as a semiautomated measurement of joint space distances at the metacarpal-phalangeal articulation (JSD-MCP 2-5), both were analyzed from plain radiographs of the nondominant hand. RESULTS: Correlations between DXR-BMD and DXR-MCI vs. parameters of RK were all significant (0.34 < R < 0.61; p < 0.01). An expected negative association was observed between RK parameters and the different scoring methods (-0.27 < R < -0.59). The maximum relative decrease in BMD vs. MCI as measured by DXR between the highest and lowest RA severity group was -27.7% vs. -27.5% (p < 0.01) for the modified Larsen Score, whereas the minimal value of relative DXR-BMD and DXR-MCI reduction could be documented for the Sharp Erosion Score (-20.8% vs. -26.8%; p < 0.01). The relative reduction of mean JSD-MCP using RK significantly varied from -25.0% (Sharp Erosion Score) to -41.2% (modified Larsen Score). In addition, an excellent reproducibility of DXR and RK could be verified. CONCLUSION: DXR in combination with RK could be a promising, widely available diagnostic tool to supplement the different scoring methods of RA with quantitative data, allowing an earlier and improved diagnosis and more precision in determining disease progression.

Adolescent↗

Computerized quantification of joint space narrowing and periarticular demineralization in patients with rheumatoid arthritis based on digital x-ray radiogrammetry.

OBJECTIVES: The aim of our work was to evaluate digital x-ray radiogrammetry (DXR) for the quantification of disease-related periarticular demineralization and computerized analysis of joint space distances (JSDA) for the measurement of joint space narrowing as a new diagnostic method for the early detection of joint-associated alterations and for monitoring disease progression in patients with rheumatoid arthritis (RA). MATERIALS AND METHODS: Digital radiographs in 313 patients with varying severity of RA were performed annually and assessed by 2 radiologists using modified Larsen and also the Sharp scores within an observation period of 3 years. The hand radiographs underwent measurements of bone mineral density (BMD) and metacarpal index (MCI) by DXR, as well as computerized JSDA at the metacarpal-phalangeal articulation (JSD-MCP) for a cross-sectional and longitudinal study design. RESULTS: Both DXR-BMD (-29.6%; P < 0.01) and DXR-MCI (-31.0%; P < 0.01) revealed a notable reduction dependent on the severity of RA (from grade 1 to grade 5 of the modified Larsen score); the severity dependent decrease of mean JSD-MCP ranged from -31.9% (P < 0.01; Sharp erosion part) to -39.1% (P < 0.01) for the modified Larsen score. Over an observation period of 3 years, a significant decrease of DXR-BMD (-22.3%) and DXR-MCI (-23.3%) as well as JSD-MCP mean (-17.5%) was observed (P < 0.05), whereas an accentuated decline of DXR and JSDA parameters was verified for patients without disease-modifying antirheumatic drugs or methotrexate therapy. CONCLUSION: Computerized analysis of hand radiographs by DXR and JSDA is a promising approach to assess the severity and to monitor the progression of RA because DXR and JSDA are timely able to measure periarticular demineralization and also narrowing of JSD-MCP dependent on the severity, the medical treatment and the course of RA.

Absorptiometry, Photon↗

Influence of image-capturing parameters on digital X-ray radiogrammetry.

The purpose of this study was to evaluate the importance of different image-capturing conditions, which might influence the characteristics of radiographs and, consequently, impact calculations of bone mineral density (BMD) and Metacarpal Index (MCI) using digital X-ray radiogrammetry (DXR). Radiographs of the left hand of deceased males were acquired three times using systematically varied parameters: 4-8 miliamp seconds (mA); 40-52 kV; film-focus distance (FFD); 90-130 cm; film sensitivity, 200/400; and different image modalities (conventional vs original digital radiographs as well as digital printouts). Furthermore, the interradiograph reproducibility using both conventional equipment and printouts vs originals of digital images and the intraradiograph reproducibility (either conventional or digital printouts) were evaluated. All BMD and MCI measurements were obtained with the DXR technology. The interradiograph reproducibility of DXR-BMD using conventional images under standardized conditions (6 mAs; 42 kV; 1 m FFD; film sensitivity of 200) was calculated to be coefficient of variation (CV) = 0.49% for Agfa Curix film and CV = 0.33% for Kodak T-MAT-Plus film, whereas reproducibility error using digital images ranged from CV = 0.57% (digital printouts; Philips) to CV = 1.50% (original digital images; Siemens). The intraradiograph reproducibility error was observed to be CV = 0.13% (conventional; Kodak film) vs CV = 0.27% (digital printouts; Philips). The BMD calculation was not noticeably affected by changes of FFD, exposure level, or film sensitivity/film brand, but was influenced by tube voltage (CV = 0.99% for Kodak film to CV = 2.05% for Siemens digital printouts). No significant differences were observed between the BMD and MCI data. DXR provides measurements of MCI and BMD with high precision and reproducibility. The measurements are unaffected by all tested image-capturing conditions, with the exception of tube voltage. In addition, different digital image devices clearly have an effect on DXR reproducibility.

Bone Density↗

Evaluation of bone-mineral density by digital X-ray radiogrammetry (DXR) in pediatric renal transplant recipients.

BACKGROUND: Loss of bone mass and increased fracture risk are known complications after renal transplantation in adults. Risk factors include donor source, dialysis status prior to transplantation, aetiology of renal disease, transplant rejection and drug therapy, particularly steroids. OBJECTIVE: In this preliminary study of quantification of bone loss in children after renal transplantion, we evaluated the applicability of digital X-ray radiogrammetry (DXR) of hand radiographs to estimate cortical bone mineral density (DXR-BMD). MATERIALS AND METHODS: A total of 23 renal transplant recipients (9 girls, 14 boys; age 6.5-20 years, median 16.3 years) underwent DXR measurements for calculation of DXR-BMD and metacarpal index (DXR-MCI) using radiographs of the non-dominant left hand. The duration between transplantation and the DXR evaluation, the duration of dialysis and medication were considered. The results were compared to a local age-matched and gender-matched reference data base. RESULTS: Our study revealed a significant decrease in bone mineral density compared to an age-matched and sex-matched normal population (P<0.05). In three patients the DXR-BMD was reduced more than -2.5 SD. In 12 patients the DXR-BMD was between -1 and -2.5 SD, and in 7 patients the DXR-BMD was in the normal range. In one patient, evaluation was not possible. Fractures were documented in three patients following transplantation. Reduced DXR-BMD was not significantly associated with immunosuppressive therapy or the duration of dialysis, and there was no significant correlation between DXR-BMD and the time between transplantation and DXR evaluation. CONCLUSIONS: Paediatric renal transplant patients show reduced DXR-BMD. In this preliminary study we demonstrated that DXR-BMD seems to be a reliable technique for quantification of demineralisation following renal transplantation in children.

Absorptiometry, Photon↗

Normative data for digital X-ray radiogrammetry from a female and male German cohort.

This study presents German reference data for digital X-ray radiogrammetry (DXR) differentiated by males as well as females, and quantifies for gender-specific and age-related differences including all DXR parameters. This study also documents the effects of different X-ray settings (e.g., radiographs of the wrist or the hand) on DXR measurements. There were 2085 patients who were prospectively enrolled (954 females and 1131 males) from a data pool of 11,915 patients with radiographs of the nondominant hand or wrist. All patients underwent measurements of bone mineral density (BMD), cortical thickness, bone width, and the metacarpal index (MCI) using DXR technology. These data showed a continuous age-related increase of the DXR parameters to the point of peak bone mass, then a continuous decline beyond the peak bone mass with accentuated age-related cortical bone loss in women. Peak bone mass is reached at approximately 30-34 yr for women and 45-49 yr for men. In addition, men had a significantly higher DXR BMD (mean: +12.8%) compared with woman in all age groups. Regarding the impact of various X-ray settings (e.g., X-ray(wrist) vs. X-ray(hand)), no significant difference was observed between both groups, men as well as women. The development of digital imaging technology has enabled more precise measurements of several radio-geometric features. The present study estimated normative reference values for DXR in German Caucasian women and men. Based on this reference data, a valid and reliable quantification of disease-related demineralization based on measurements of DXR BMD and MCI is now available for the Caucasian ethnic group.

Absorptiometry, Photon↗