Dual-source CT cardiac imaging: initial experience.

The relation of heart rate and image quality in the depiction of coronary arteries, heart valves and myocardium was assessed on a dual-source computed tomography system (DSCT). Coronary CT angiography was performed on a DSCT (Somatom Definition, Siemens) with high concentration contrast media (Iopromide, Ultravist 370, Schering) in 24 patients with heart rates between 44 and 92 beats per minute. Images were reconstructed over the whole cardiac cycle in 10% steps. Two readers independently assessed the image quality with regard to the diagnostic evaluation of right and left coronary artery, heart valves and left ventricular myocardium for the assessment of vessel wall changes, coronary stenoses, valve morphology and function and ventricular function on a three point grading scale. The image quality ratings at the optimal reconstruction interval were 1.24+/-0.42 for the right and 1.09+/-0.27 for the left coronary artery. A reconstruction of diagnostic systolic and diastolic images is possible for a wide range of heart rates, allowing also a functional evaluation of valves and myocardium. Dual-source CT offers very robust diagnostic image quality in a wide range of heart rates. The high temporal resolution now also makes a functional evaluation of the heart valves and myocardium possible.

Algorithms↗

Accuracy of 64-slice computed tomography to classify and quantify plaque volumes in the proximal coronary system: a comparative study using intravascular ultrasound.

OBJECTIVES: We evaluated the accuracy of a new 64-slice computed tomography (CT) scanner, compared with intravascular ultrasound, to visualize atherosclerosis in the proximal coronary system. BACKGROUND: Noninvasive determination of plaque composition and plaque burden may be important to improve risk stratification. METHODS: In 20 patients, a 64-slice CT scan (Sensation 64, Siemens Medical Solutions, Forchheim, Germany) and an intravascular ultrasound investigation of vessels without stenosis >50% was performed. Diagnostic image quality with 64-slice CT was obtained in 36 vessels in 19 patients. RESULTS: In these vessels, which were divided in 3-mm sections, 64-slice CT enabled a correct detection of plaque in 54 of 65 (83%) sections containing noncalcified plaques, 50 of 53 (94%) sections containing mixed plaques, and 41 of 43 (95%) sections containing calcified plaques. In 192 of 204 (94%) sections, atherosclerotic lesions were excluded correctly. In addition, 64-slice CT enabled the visualization of 7 of 10 (70%) sections revealing a lipid pool and could identify a spotty calcification pattern in 27 of 30 (90%) sections. The correlation coefficient to determine plaque volumes per vessel was r2 = 0.69 (p < 0.001) with an underestimation of mixed and noncalcified plaque volumes (p < 0.03) and a trend to overestimate calcified plaque volumes by 64-slice CT. The interobserver variability to determine plaque volumes was 37%. Interobserver agreement to identify atherosclerotic sections was good (Cohen's kappa coefficient = 0.75). CONCLUSIONS: We conclude that 64-slice CT reveals encouraging results to noninvasively detect different types of coronary plaques located in the proximal coronary system. The ability to determine plaque burden currently is hampered by mainly an insufficient reproducibility.

Coronary Angiography↗

Assessment of coronary artery stent patency and restenosis using 64-slice computed tomography.

RATIONALE AND OBJECTIVES: Restenosis remains a major limitation of coronary catheter-based stent placement. Therefore, a reliable noninvasive diagnostic method for the evaluation of stented coronary arteries would be highly desirable. Our aim was to evaluate the diagnostic accuracy of high-resolution 64-slice computed tomography (64SCT) in a pilot study for the assessment of the lumen of coronary artery stents. MATERIALS AND METHODS: Twenty-five patients underwent 64SCT of the coronary arteries and quantitative x-ray coronary angiography (QCA) after coronary artery stent placement. 64SCT coronary angiography was performed with the following parameters: spatial resolution = 0.4 x 0.4 x 0.4 mm; temporal resolution = 83-165 milliseconds; contrast agent = 80 mL at a flow rate of 5 mL/second; retrospective electrocardiogram gating. The 64SCT scans were evaluated for image quality and for the presence of significant in-stent and peri-stent (proximal and distal) stenoses. Determinations were made of the sensitivity, specificity, diagnostic accuracy, and positive and negative predictive values (PPV and NPV) of 64SCT for the detection or exclusion of stenoses. RESULTS: A total of 46 stents were evaluated, of which 45 (98%) were of diagnostic image quality. Significant in-stent restenosis or occlusion was detected on QCA in 8/45 cases (>/=50% stenosis = 6; occlusion = 2). The sensitivity, specificity, accuracy, PPV, and NPV of 64SCT for the detection of significant in-stent disease was 75%, 92%, 89%, 67%, and 94%, respectively. Both occluded coronary artery stents were correctly identified. The sensitivity, specificity, and accuracy values of 64SCT for the detection of significant proximal peri-stent stenoses were 75%, 95%, and 93%, respectively, whereas the values for detection of significant distal peri-stent stenoses were 67%, 85%, and 84%, respectively. CONCLUSION: The high spatial and temporal resolution of 64SCT may permit improved assessment of stent occlusion and peri-stent disease, although detection of in-stent stenosis remains difficult.

Adult↗

Quantification of obstructive and nonobstructive coronary lesions by 64-slice computed tomography: a comparative study with quantitative coronary angiography and intravascular ultrasound.

OBJECTIVES: The aim of the present study was to determine the diagnostic accuracy of 64-slice computed tomography (CT) to identify and quantify atherosclerotic coronary lesions in comparison with catheter-based angiography and intravascular ultrasound (IVUS). BACKGROUND: Currently, the ability of multislice CT to quantify the degree of coronary artery stenosis and dimensions of coronary plaques has not been evaluated. METHODS: We included 59 patients scheduled for coronary angiography due to stable angina pectoris. A contrast-enhanced 64-slice CT (Senation 64, Siemens Medical Solutions, Forchheim, Germany) was performed before the invasive angiogram. In a subset of 18 patients, IVUS of 32 vessels was part of the catheterization procedure. RESULTS: In 55 of 59 patients, 64-slice CT enabled the visualization of the entire coronary tree with diagnostic image quality (American Heart Association 15-segment model). The overall correlation between the degree of stenosis detected by quantitative coronary angiography compared with 64-slice CT was r = 0.54. Sensitivity for the detection of stenosis <50%, stenosis >50%, and stenosis >75% was 79%, 73%, and 80%, respectively, and specificity was 97%. In comparison with IVUS, 46 of 55 (84%) lesions were identified correctly. The mean plaque areas and the percentage of vessel obstruction measured by IVUS and 64-slice CT were 8.1 mm2 versus 7.3 mm2 (p < 0.03, r = 0.73) and 50.4% versus 41.1% (p < 0.001, r = 0.61), respectively. CONCLUSIONS: Contrast-enhanced 64-slice CT is a clinically robust modality that allows the identification of proximal coronary lesions with excellent accuracy. Measurements of plaque and lumen areas derived by CT correlated well with IVUS. A major limitation is the insufficient ability of CT to exactly quantify the degree of stenosis.

Aged↗

Visualising noncalcified coronary plaques by CT.

Due to a rapid improvement of the new generation submillimetre multislice CT-technology noninvasive tomographic imaging of the coronary vessel wall has become reality. First clinical studies have shown the ability in particular of 16-slice CT to determine plaque burden, plaque composition and compensatory vessel-wall remodelling. These novel findings already constitute an important step forward to assess coronary atherosclerosis noninvasively in a detailed manner which opens promising new opportunities for a better understanding and riskstratification of coronary atherosclerosis. Current limitations, mainly the insufficient accuracy to detect small lesions in distal coronary segments, might be overcome by improved spatial and temporal resolution of the new generation scanners operating with 64 and more detectors.

Contrast Media↗

Accuracy of multidetector spiral computed tomography in identifying and differentiating the composition of coronary atherosclerotic plaques: a comparative study with intracoronary ultrasound.

OBJECTIVES: We evaluated the accuracy of contrast-enhanced multidetector spiral computed tomography (MDCT) for the noninvasive detection and classification of coronary plaques and compared it with intracoronary ultrasound (ICUS). BACKGROUND: Noninvasive determination of plaque composition and plaque burden may be important to improve risk stratification and to monitor progression of coronary atherosclerosis. METHODS: We included 46 consecutive patients with a distinctive risk profile, who were investigated by ICUS (Goldvision, 20 MHz, Jomed Inc., Rancho Cordova, California). Due to the inability to slow the heart rate below 65 beats/min (n = 7) and due to renal insufficiency (n = 2), nine of 46 consecutive patients could not be studied by MDCT (Sensation 16, Siemens, Forchheim, Germany). RESULTS: In the remaining 37 patients, 68 vessels were investigated by ICUS, and 58 of these vessels were visualized by MDCT with image quality sufficient for analysis. In these vessels that were divided in 3-mm sections, MDCT correctly classified 62 of 80 (78%) sections containing hypoechoic plaque areas, 87 of 112 (78%) sections containing hyperechoic plaque areas, and 150 of 158 (95%) sections containing calcified plaque tissue. In 484 of 525 (92%) sections, atherosclerotic lesions were correctly excluded. The MDCT-derived density measurements within coronary lesions revealed significantly different values for hypoechoic (49 HU [Hounsfield Units] +/- 22), hyperechoic (91 HU +/- 22), and calcified plaques (391 HU +/- 156, p < 0.02). CONCLUSIONS: This study demonstrates that, in the case of diagnostic image quality, contrast-enhanced MDCT permits an accurate identification of coronary plaques and that computed tomography density values measured within plaques reflect echogenity and plaque composition.

Aged↗