PubMed Health⌕ Search

Biomedical subjects

Alexander Ya Supin

Publications and source records attributed to Alexander Ya Supin.

10 recordsLinked to original sources

Monaural and binaural hearing directivity in the bottlenose dolphin: evoked-potential study.

Hearing thresholds as a function of sound-source azimuth were measured in bottlenose dolphins using an auditory evoked potential (AEP) technique. AEP recording from a region next to the ear allowed recording monaural responses. Thus, a monaural directivity diagram (a threshold-vs-azimuth function) was obtained. For comparison, binaural AEP components were recorded from the vertex to get standard binaural directivity diagrams. Both monaural and binaural diagrams were obtained at frequencies ranging from 8 to 128 kHz in quarter-octave steps. At all frequencies, the monaural diagram demonstrated asymmetry manifesting itself as: (1) lower thresholds at the ipsilateral azimuth as compared to the symmetrical contralateral azimuth and (2) ipsilateral shift of the lowest-threshold point. The directivity index increased with frequency: at the ipsilateral side it rose from 4.7 to 17.8 dB from 11.2 to 128 kHz, and from 10.5 to 15.6 dB at the contralateral side. The lowest-threshold azimuth shifted from 0 degrees at 90-128 kHz to 22.5 degrees at 8-11.2 kHz. The frequency-dependent variation of the lowest-threshold azimuth indicates the presence of two sound-receiving apertures at each head side: a high-frequency aperture with the axis directed frontally, and a low-frequency aperture with the axis directed laterally.

Acoustic Stimulation↗

Nonconstant quality of auditory filters in the porpoises, Phocoena phocoena and Neophocaena phocaenoides (Cetacea, Phocoenidae).

Simultaneous tone-tone masking in conjunction with the envelope-following response (EFR) recording was used to obtain tuning curves in porpoises Phocoena phocoena and Neophocaena phocaenoides asiaeorientalis. The EFR was evoked by amplitude-modulated probes with a modulation rate of 1000 Hz and carrier frequencies from 22.5 to 140 kHz. Equivalent rectangular quality QERB of the obtained tuning curves varied from 8.3-8.6 at lower (22.5-32 kHz) probe frequencies to 44.8-47.4 at high (128-140 kHz) frequencies. The QERB dependence on probe frequency could be approximated by regression lines with a slope of 0.83 to 0.86 in log-log scale, which corresponded to almost frequency-proportional quality and almost constant bandwidth of 3-4 kHz. Thus, the frequency representation in the porpoise auditory system is much closer to a constant-bandwidth rather that to a constant-quality manner.

Animals↗

Source-to-sensation level ratio of transmitted biosonar pulses in an echolocating false killer whale.

Transmitted biosonar pulses, and the brain auditory evoked potentials (AEPs) associated with those pulses, were synchronously recorded in a false killer whale Pseudorca crassidens trained to accept suction-cup EEG electrodes and to detect targets by echolocation. AEP amplitude was investigated as a function of the transmitted biosonar pulse source level. For that, a few thousand of the individual AEP records were sorted according to the spontaneously varied amplitude of synchronously recorded biosonar pulses. In each of the sorting bins (in 5-dB steps) AEP records were averaged to extract AEP from noise; AEP amplitude was plotted as a function of the biosonar pulse source level. For comparison, AEPs were recorded to external (in free field) sound pulses of a waveform and spectrum similar to those of the biosonar pulses; amplitude of these AEPs was plotted as a function of sound pressure level. A comparison of these two functions has shown that, depending on the presence or absence of a target, the sensitivity of the whale's hearing to its own transmitted biosonar pulses was 30 to 45 dB lower than might be expected in a free acoustic field.

Acoustics↗

Rippled-spectrum resolution dependence on masker-to-probe ratio.

Resolution of rippled sound spectrum (probe) in the presence of additional noise band (masker) was studied as a function of masker-to-probe ratio and sound level in normal listeners. The probe bands were 0.5-oct wide (ERB) centered at 2 kHz; the masker band either coincided with the probe (on-frequency masker), or was 3/4 octaves below (low-frequency masker), or 3/4 octaves above the probe (high-frequency masker). Ripple-density resolution in the probe band was measured by finding the highest ripple density at which an interchange of ripple peaks and valleys was detectable (the phase-reversal test). (i) The effect of the low-frequency masker increased (resolution decreased) when masker-to-probe ratio changed from -25 dB to +20 dB; the effect increased (resolution decreased) with sound level increase. (ii) The effect of the on-frequency masker steeply increased (resolution abruptly decreased) when masker-to-probe ratio exceeded 0 dB; the effect was little dependent on sound level. (iii) The high-frequency masker was little effective unless the masker-to-probe ratio reached 30-40 dB; the effect increased (resolution decreased) with sound level decrease. Thus, different position of the masker band relative to the probe resulted in qualitatively different kinds of spectrum-pattern resolution dependence on both the masker-to-probe ratio and sound level.

Acoustic Stimulation↗

Invariance of evoked-potential echo-responses to target strength and distance in an echolocating false killer whale.

Brain auditory evoked potentials (AEPs) were recorded in a false killer whale Pseudorca crassidens trained to accept suction-cup EEG electrodes and to detect targets by echolocation. AEP collection was triggered by echolocation pulses transmitted by the animal. The target strength varied from -22 to -40 dB; the distance varied from 1.5 to 6 m. All the records contained two AEP sets: the first one of a constant latency (transmission-related AEP) and a second one with a delay proportional to the distance (echo-related AEP). The amplitude of echo-related AEPs was almost independent of both target strength and distance, though combined variation of these two parameters resulted in echo intensity variation within a range of 42 dB. The amplitude of transmission-related AEPs was independent of distance but dependent on target strength: the less the target strength, the higher the amplitude. Recording of transmitted pulses has not shown their intensity dependence on target strength. It is supposed that the constancy of echo-related AEP results from variation of hearing sensitivity depending on the target strength and release of echo-related responses from masking by transmitted pulses depending on the distance.

Animals↗

Behavioral and auditory evoked potential audiograms of a false killer whale (Pseudorca crassidens).

Behavioral and auditory evoked potential (AEP) audiograms of a false killer whale were measured using the same subject and experimental conditions. The objective was to compare and assess the correspondence of auditory thresholds collected by behavioral and electrophysiological techniques. Behavioral audiograms used 3-s pure-tone stimuli from 4 to 45 kHz, and were conducted with a go/no-go modified staircase procedure. AEP audiograms used 20-ms sinusoidally amplitude-modulated tone bursts from 4 to 45 kHz, and the electrophysiological responses were received through gold disc electrodes in rubber suction cups. The behavioral data were reliable and repeatable, with the region of best sensitivity between 16 and 24 kHz and peak sensitivity at 20 kHz. The AEP audiograms produced thresholds that were also consistent over time, with range of best sensitivity from 16 to 22.5 kHz and peak sensitivity at 22.5 kHz. Behavioral thresholds were always lower than AEP thresholds. However, AEP audiograms were completed in a shorter amount of time with minimum participation from the animal. These data indicated that behavioral and AEP techniques can be used successfully and interchangeably to measure cetacean hearing sensitivity.

Acoustic Stimulation↗

The interaction of outgoing echolocation pulses and echoes in the false killer whale's auditory system: evoked-potential study.

Brain auditory evoked potentials (AEP) associated with echolocation were recorded in a false killer whale Pseudorca crassidens trained to accept suction-cup EEG electrodes and to detect targets by echolocation. AEP collection was triggered by echolocation pulses transmitted by the animal. The target was a hollow aluminum cylinder of strength of -22 dB at a distance from 1 to 8 m. Each AEP record was obtained by averaging more than 1000 individual records. All the records contained two AEP sets: the first one of a constant latency and a second one with a delay proportional to the distance. The timing of these two AEP sets was interpreted as responses to the transmitted echolocation pulse and echo, respectively. The echo-related AEP, although slightly smaller, was comparable to the outgoing click-related AEP in amplitude, even though at a target distance as far as 8 m the echo intensity was as low as -64 dB relative to the transmitted pulse in front of the head. The amplitude of the echo-related AEP was almost independent of distance, even though variation of target distance from 1 to 8 m influenced the echo intensity by as much as 36 dB.

Acoustic Stimulation↗

Rippled-spectrum resolution dependence on level.

Rippled-density resolution of a rippled sound spectrum (probe band) in both the presence and absence of another band (masker) was studied as a function of sound level in normal listeners. The resolvable ripple density in the probe band was measured by finding the highest ripple density at which an interchange of ripple peak and valley positions was detectable (the phase-reversal test). Probe bands were 0.5 oct wide with center frequencies of 1, 2, and 4 kHz. In the control condition (no masker), the ripple-density resolution was almost independent of sound level within a range of 40-90 dB SPL. When an on-frequency masker coincided with the probe band (that resulted in reduced ripple depth), resolution decreased slightly relative to the control condition but remained little dependent on level. With an off-frequency low-side masker, the ripple-density resolution was a little less than in the control but almost independent of level within a range of 40-60 dB SPL and progressively decreased with level increase from 70 to 90 dB SPL. The dependence on level was qualitatively similar at all probe frequencies and at various widths and positions of the low-side off-frequency masker band.

Acoustic Stimulation↗