PubMed Health⌕ Search

Biomedical subjects

Alexander Zybin

Publications and source records attributed to Alexander Zybin.

3 recordsLinked to original sources

Differential surface plasmon resonance imaging for high-throughput bioanalyses.

A new imaging technique for high-throughput surface plasmon resonance (SPR) measurements is described. It is the application of a CCD camera for simultaneous processing of two images at two different wavelengths provided by two laser diodes. The two lasers are brought to resonance by tuning of the angle of incidence so that the detection power and the dynamic range are optimized for the wavelength pair selected. Applying a special differential processing of the two images, SPR measurements can be performed near the shot noise limit taking into account the number of CCD pixels involved. It is shown that the detection limit of imaging methods can be improved significantly if the working point is set near to the reflection minimum instead of choosing the angle with the steepest slope of the reflection curve. The technique is demonstrated by simultaneous measurement of hybridization reactions of three different types of thiolated oligonucleotides in 30 small areas set by a commercial spotter. A noise level of 1.5 x 10(-6) refractive index units (RIU) was obtained for single, 500 x 500 microm2 reaction areas. The noise level was about 6 x 10(-7) RIU when five areas were taken into account. The present arrangement and the particular spotter applied would allow simultaneous measurements of up to 400 binding reactions with a noise level of about 1.5 x 10(-6) RIU.

DNA↗

Double-wavelength technique for surface plasmon resonance measurements: basic concept and applications for single sensors and two-dimensional sensor arrays.

A new technique for on-line monitoring of analyte binding to sensor surfaces by surface plasmon resonance (SPR) detection is described. It is based on differential measurements using two wavelengths provided by two diode lasers. The technique is as simple and robust as the conventional SPR detection measuring the reflected radiation at fixed incidence angle, but it has the advantage of being nonsensitive to variations of the resonance width and providing essentially higher signal/noise ratios. The paper presents the first four channel prototype system for parallel 2D-monitoring at four different spots. One channel is always used as a reference to compensate temperature fluctuations and nonspecific adsorptions. Calibration with sucrose solutions revealed an absolute sensitivity of Deltan approximately 5 x 10(-6). The new technique is tested with a biotin-streptavidin binding and with hybridization/denaturation of DNA. Biotin binding to a streptavidin monolayer is detected with a signal/noise ratio of about 5, which demonstrates the high potential of the new technique for applications in drug discovery. Applications to gene analysis are tested with short oligonucleotides of the sequences used for genotyping human hepatitis C viruses. A selective response to complementary oligonucleotides is observed. The high reproducibility in subsequent cycles of hybridization/denaturation (by formamide or by heating) points out potential applications of the technique in medical diagnostics, food industry, genomics, and proteomics too.

Biosensing Techniques↗