PubMed Health⌕ Search

Biomedical subjects

Alexandre A Shvartsburg

Publications and source records attributed to Alexandre A Shvartsburg.

16 recordsLinked to original sources

Field asymmetric waveform ion mobility spectrometry studies of proteins: Dipole alignment in ion mobility spectrometry?

Approaches to separation and characterization of ions based on their mobilities in gases date back to the 1960s. Conventional ion mobility spectrometry (IMS) measures the absolute mobility, and field asymmetric waveform IMS (FAIMS) exploits the difference between mobilities at high and low electric fields. However, in all previous IMS and FAIMS experiments ions experienced an essentially free rotation; thus the separation was based on the orientationally averaged cross-sections Omega(avg) between ions and buffer gas molecules. Virtually all large ions are permanent electric dipoles that will be oriented by a sufficiently strong electric field. Under typical FAIMS conditions this will occur for dipole moments >400 D, found for many macroions including most proteins above approximately 30 kDa. Mobilities of aligned dipoles depend on directional cross-sections Omega(dir) (rather than Omega(avg)), which should have a major effect on FAIMS separation parameters. Here we report the FAIMS behavior of electrospray-ionization-generated ions for 10 proteins up to approximately 70 kDa. Those above 29 kDa exhibit a strong increase of mobility at high field, which is consistent with predicted ion dipole alignment. This effect expands the useful FAIMS separation power by an order of magnitude, allowing separation of up to approximately 10(2) distinct protein conformers and potentially revealing information about Omega(dir) and ion dipole moment that is of utility for structural characterization. Possible approaches to extending dipole alignment to smaller ions are discussed.

Electrochemistry↗

Improving mass spectrometer sensitivity using a high-pressure electrodynamic ion funnel interface.

We report on a new electrodynamic ion funnel that operates at a pressure of 30 torr with no loss of ion transmission. The enhanced performance compared with previous ion funnel designs optimized for pressures of <5 torr was achieved by reducing the ion funnel capacitance and increasing the RF drive frequency (1.7 MHz) and amplitude (100-170 V peak-to-peak). No degradation of ion transmission was observed for pressures from 2 to 30 torr. The ability to operate at higher pressure enabled a new tandem ion funnel mass spectrometer interface design that can accommodate a greater gas load (e.g., from an ESI source). When combined with a multicapillary inlet, the interface provided more efficient introduction of ions, resulting in a significant enhancement in mass spectrometer sensitivity and detection limits.

Equipment Design↗

High-resolution field asymmetric waveform ion mobility spectrometry using new planar geometry analyzers.

Field asymmetric waveform ion mobility spectrometry (FAIMS) has emerged as a powerful tool of broad utility for separation and characterization of gas-phase ions, especially in conjunction with mass spectrometry (MS). In FAIMS, ions are filtered by the dependence of mobility on electric field while being carried by gas flow through the analytical gap between two electrodes of either planar (p-) or cylindrical (c-) geometry. Most FAIMS/MS systems employ c-FAIMS because of its ease of coupling to MS, yet the merits of the two geometries have not been compared in detail. Here, a priori simulations reveal that reducing the FAIMS curvature always improves resolution at equal sensitivity. In particular, the resolving power of p-FAIMS exceeds that of c-FAIMS, typically by a factor of 2-4 depending on the ion species and carrier gas. We have constructed a new planar FAIMS incorporating a curtain plate interface for effective operation with an ESI ion source and joined to an MS using an ion funnel interface with a novel slit aperture. The resolution increases up to 4-fold over existing c-FAIMS, even though the analysis is approximately 2 times faster. This allows separation of species not feasible in previous FAIMS studies, e.g., protonated leucine and isoleucine or new bradykinin isomers. The improvement for protein conformers (of ubiquitin) is less significant, possibly because of multiple unresolved geometries.

Computer Simulation↗

Characterizing the structures and folding of free proteins using 2-D gas-phase separations: observation of multiple unfolded conformers.

Understanding the 3-D structure and dynamics of proteins and other biological macromolecules in various environments is among the central challenges of chemistry. Electrospray ionization can often transfer ions from solution to gas phase with only limited structural distortion, allowing their profiling using mass spectrometry and other gas-phase approaches. Ion mobility spectrometry (IMS) can separate and characterize macroion conformations with high sensitivity and speed. However, IMS separation power is generally insufficient for full resolution of major structural variants of protein ions and elucidation of their interconversion dynamics. Here we report characterization of macromolecular conformations using field asymmetric waveform IMS (FAIMS) coupled to conventional IMS in conjunction with mass spectrometry. The collisional heating of ions in the electrodynamic funnel trap between FAIMS and IMS stages enables investigating the structural evolution of particular isomeric precursors as a function of the intensity and duration of activation that can be varied over large ranges. These new capabilities are demonstrated for ubiquitin and cytochrome c, two common model proteins for structure and folding studies. For nearly all charge states, two-dimensional FAIMS/IMS separations distinguish many more conformations than either FAIMS or IMS alone, including some with very low abundance. For cytochrome c in high charge states, we find several abundant "unfolded" isomer series not distinguishable by IMS, possibly corresponding to different "string of beads" geometries. The unfolding of specific ubiquitin conformers selected by FAIMS has been studied by employing their heating in the FAIMS/IMS interface.

Cytochromes c↗

Feasibility of higher-order differential ion mobility separations using new asymmetric waveforms.

Technologies for separating and characterizing ions based on their transport properties in gases have been around for three decades. The early method of ion mobility spectrometry (IMS) distinguished ions by absolute mobility that depends on the collision cross section with buffer gas atoms. The more recent technique of field asymmetric waveform IMS (FAIMS) measures the difference between mobilities at high and low electric fields. Coupling IMS and FAIMS to soft ionization sources and mass spectrometry (MS) has greatly expanded their utility, enabling new applications in biomedical and nanomaterials research. Here, we show that time-dependent electric fields comprising more than two intensity levels could, in principle, effect an infinite number of distinct differential separations based on the higher-order terms of expression for ion mobility. These analyses could employ the hardware and operational procedures similar to those utilized in FAIMS. Methods up to the 4th or 5th order (where conventional IMS is 1st order and FAIMS is 2nd order) should be practical at field intensities accessible in ambient air, with still higher orders potentially achievable in insulating gases. Available experimental data suggest that higher-order separations should be largely orthogonal to each other and to FAIMS, IMS, and MS.

Gases↗

Improved cell typing by charge-state deconvolution of matrix-assisted laser desorption/ionization mass spectra.

Robust, specific, and rapid identification of toxic strains of bacteria and viruses, to guide the mitigation of their adverse health effects and optimum implementation of other response actions, remains a major analytical challenge. This need has driven the development of methods for classification of microorganisms using mass spectrometry, particularly matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS), that allows high-throughput analyses with minimum sample preparation. We describe a novel approach to cell typing based on pattern recognition of MALDI mass spectra, which involves charge-state deconvolution in conjunction with a new correlation analysis procedure. The method is applicable to both prokaryotic and eukaryotic cells. Charge-state deconvolution improves the quantitative reproducibility of spectra because multiply charged ions resulting from the same biomarker attaching a different number of protons are recognized and their abundances are combined. This allows a clearer distinction of bacterial strains or of cancerous and normal liver cells. Improved class distinction provided by charge-state deconvolution was demonstrated by cluster spacing on canonical variate score charts and by correlation analyses. Deconvolution may enhance detection of early disease state or therapy progress markers in various tissues analyzed by MALDI-MS.

Algorithms↗

Two-dimensional gas-phase separations coupled to mass spectrometry for analysis of complex mixtures.

Ion mobility spectrometry (IMS) has been explored for decades, and its versatility in separation and identification of gas-phase ions is well established. Recently, field asymmetric waveform IMS (FAIMS) has been gaining acceptance in similar applications. Coupled to mass spectrometry (MS), both IMS and FAIMS have shown the potential for broad utility in proteomics and other biological analyses. A major attraction of these separations is extremely high speed, exceeding that of condensed-phase alternatives by orders of magnitude. However, modest separation peak capacities have limited the utility of FAIMS and IMS for analyses of complex mixtures. We report 2-D gas-phase separations that join FAIMS to IMS, in conjunction with high-resolution and accuracy time-of-flight (TOF) MS. Implementation of FAIMS/IMS and IMS/MS interfaces using electrodynamic ion funnels greatly improves sensitivity. Evaluation of FAIMS/IMS/TOF performance for a protein mixture tryptic digest reveals high orthogonality between FAIMS and IMS dimensions and, hence, the benefit of FAIMS filtering prior to IMS/MS. The effective peak capacities in analyses of tryptic peptides are approximately 500 for FAIMS/IMS separations and approximately 10(6) for 3-D FAIMS/IMS/MS, providing a potential platform for ultrahigh-throughput analyses of complex mixtures.

Gases↗

High-sensitivity ion mobility spectrometry/mass spectrometry using electrodynamic ion funnel interfaces.

The utility of ion mobility spectrometry (IMS) for separation of mixtures and structural characterization of ions has been demonstrated extensively, including in biological and nanoscience contexts. A major attraction of IMS is its speed, several orders of magnitude greater than that of condensed-phase separations. Nonetheless, IMS combined with mass spectrometry (MS) has remained a niche technique, substantially because of limited sensitivity resulting from ion losses at the IMS-MS junction. We have developed a new electrospray ionization (ESI)-IMS-QTOF MS instrument that incorporates electrodynamic ion funnels at both front ESI-IMS and rear IMS-QTOF interfaces. The front funnel is of the novel "hourglass" design that efficiently accumulates ions and pulses them into the IMS drift tube. Even for drift tubes of 2-m length, ion transmission through IMS and on to QTOF is essentially lossless across the range of ion masses relevant to most applications. The rf ion focusing at the IMS terminus does not degrade IMS resolving power, which exceeds 100 (for singly charged ions) and is close to the theoretical limit. The overall sensitivity of the present ESI-IMS-MS system is comparable to that of commercial ESI-MS, which should make IMS-MS suitable for analyses of complex mixtures with ultrahigh sensitivity and exceptional throughput.

Electrochemistry↗

Optimization of the design and operation of FAIMS analyzers.

Field asymmetric waveform ion mobility spectrometry (FAIMS) holds significant promise for post-ionization separations in conjunction with mass-spectrometric analyses. However, a limited understanding of fundamentals of FAIMS analyzers has made their design and operation largely an empirical exercise. Recently, we developed an a priori simulation of FAIMS that accounts for both ion diffusion (including anisotropic components) and Coulomb repulsion, and validated it by extensive comparisons with FAIMS/MS data. Here it is corroborated further by FAIMS-only measurements, and applied to explore how key instrumental parameters (analytical gap width and length, waveform frequency and profile, the identity and flow speed of buffer gas) affect FAIMS response. We find that the trade-off between resolution and sensitivity can be managed by varying gap width, RF frequency, and (in certain cases) buffer gas, with equivalent outcome. In particular, the resolving power can be approximately doubled compared to "typical" conditions. Throughput may be increased by either accelerating the gas flow (preferable) or shortening the device, but below certain minimum residence times performance deteriorates. Bisinusoidal and clipped-sinusoidal waveforms have comparable merit, but switching to rectangular waveforms would improve resolution and/or sensitivity. For any waveform profile, the ratio of two between voltages in high and low portions of the cycle produces the best performance.

Computer Simulation↗

FAIMS operation for realistic gas flow profile and asymmetric waveforms including electronic noise and ripple.

The use of field asymmetric waveform ion mobility spectrometry (FAIMS) has rapidly grown with the advent of commercial FAIMS systems coupled to mass spectrometry. However, many fundamental aspects of FAIMS remain obscure, hindering its technological improvement and expansion of analytical utility. Recently, we developed a comprehensive numerical simulation approach to FAIMS that can handle any device geometry and operating conditions. The formalism was originally set up in one dimension for a uniform gas flow and limited to ideal asymmetric voltage waveforms. Here we extend the model to account for a realistic gas flow velocity distribution in the analytical gap, axial ion diffusion, and waveform imperfections (e.g., noise and ripple). The nonuniformity of the gas flow velocity profile has only a minor effect, slightly improving resolution. Waveform perturbations are significant even at very low levels, in some cases approximately 0.01% of the nominal voltage. These perturbations always improve resolution and decrease sensitivity, a trade-off controllable by variation of noise or ripple amplitude. This trade-off is physically inferior to that obtained by adjusting the gap width and/or asymmetric waveform frequency. However, the disadvantage is negligible when the perturbation period is much shorter than the residence time in FAIMS, and ripple adjustment appears to offer a practical method for modifying FAIMS resolution.

Algorithms↗

Understanding and designing field asymmetric waveform ion mobility spectrometry separations in gas mixtures.

Field asymmetric waveform ion mobility spectrometry (FAIMS) has significant potential for post-ionization separations in conjunction with MS analyses. FAIMS fractionates ion mixtures by exploiting the fact that ion mobilities in gases depend on the electric field in a manner specific to each ion. Nearly all previous work has used pure gases, for which FAIMS fundamentals are understood reasonably well; however, unexpected phenomena observed in some gas mixtures (e.g., N(2)/CO(2)) but not in others (N(2)/O(2)) remain unexplained. Here, we introduce and experimentally test a universal model for FAIMS separations in mixtures, derived from formalisms that determine high-field mobilities in heteromolecular gases. Overall, the theoretical findings are consistent with data for N(2)/CO(2) (although quantitative discrepancies remain), while results for N(2)/O(2) fit Blanc's law, in agreement with measurements. Calculations for He/N(2) and He/CO(2) are also consistent with observations and suggest why adding He to the working gas generally enhances FAIMS performance. As predicted, mixtures of gases with extremely disparate molecular masses and collision cross sections, such as He/SF(6), exhibit spectacular non-Blanc effects, which greatly improve the resolution and peak capacity of technique. Understanding FAIMS operation in gas mixtures is expected to enable the rational design of media for both targeted and global analyses.

Carbon Dioxide↗

Attachment of metal trications to peptides.

Gas-phase complexes of triply charged metal ions with peptides may be readily produced using electrospray ionization, including for small peptides such as bradykinin and peptides with no basic residues such as insulin chain A. Attachment without charge-reduction is demonstrated for all trications studied: La(3+), Al(3+), Ga(3+), Fe(3+), V(3+), and Cr(3+). The intensities of adducts are often comparable to, or even exceed, those of protonated analogs in any charge state.

Cations↗

Modeling the resolution and sensitivity of FAIMS analyses.

Field asymmetric waveform ion mobility spectrometry (FAIMS) is rapidly gaining acceptance as a robust, versatile tool for post-ionization separations prior to mass-spectrometric analyses. The separation is based on differences between ion mobilities at high and low electric fields, and proceeds at atmospheric pressure. Two major advantages of FAIMS over condensed-phase separations are its high speed and an ion focusing effect that often improves sensitivity. While selected aspects of FAIMS performance are understood empirically, no physical model rationalizing the resolving power and sensitivity of the method and revealing their dependence on instrumental variables has existed. Here we present a first-principles computational treatment capable of simulating the FAIMS analyzer for virtually any geometry (including the known cylindrical and planar designs) and arbitrary operational parameters. The approach involves propagating an ensemble of ion trajectories through the device in real time under the influence of applied asymmetric potential, diffusional motion incorporating the high-field and anisotropic phenomena, and mutual Coulomb repulsion of ionic charges. Calculations for both resolution and sensitivity are validated by excellent agreement with measurements in different FAIMS modes for ions representing diverse types and analyte classes.

Amino Acids↗

DMSO complexes of trivalent metal ions: first microsolvated trications outside of group 3.

The advent of electrospray ionization source opened the door to generation of multiply charged metal ions complexed with organic molecules. A significant amount of work on ligated dications has appeared over the past decade. In contrast, only several microsolvated tripositive ions have been reported, involving solely the few rare earths with the lowest third ionization energies (IEs) of all elements (<23 eV). Here trications of numerous trivalent metals outside of group 3 are shown to coordinate dimethyl sulfoxide (DMSO), an eminent aprotic solvent. These include both main group elements (Al, Ga, In, Bi) and transition metals (V, Fe, Cr) with the third IE up to 31 eV, which is 22 eV above the IE of DMSO. Fragmentation of M(3+)(DMSO)(n) for these metals (plus La, Yb, and Sc) has been characterized in detail using collision-induced dissociation (CID). A rich, highly element specific dissociation chemistry is observed, including the homolytic C-S cleavage in (+3) charge state and various charge-reduction processes, such as dissociative electron and proton transfer and heterolytic S=O cleavage with and without a concomitant proton transfer. Characteristic sizes for the charge reduction in M(3+)(DMSO)(n) and M(2+)(DMSO)(n) have been measured as a function of the relevant elemental IE. These reveal no intrinsic gap between the stabilities of dication and trication complexes, once the IE is adjusted for. This, in particular, suggests that even microsolvated tetracations may exist.

Journal Article↗

Isomer-resolved ion spectroscopy.

We demonstrate the isomer-resolved spectroscopy of gas-phase ions, with different geometries separated prior to spectroscopic probe using ion mobility techniques. Specifically, ring and chain isomers of carbon cluster anions with 10;-12 atoms have been separated by ion mobility/mass spectrometry and examined by photoelectron spectroscopy. This methodology should also apply to other ion spectroscopies, including IR photodissociation.

Journal Article↗

Gas-phase metal trications in protic solvent complexes.

In the first observation of triply charged metal ions microsolvated by protic ligands, gas-phase complexes of 11 different metal trications with diacetone alcohol were generated using electrospray ionization. These species were found to exist for at least five to eight ligands, depending on the metal. For smaller sizes, charge reduction to dications occurs spontaneously via dissociative proton transfer. This is the largest minimum size reported for any multiply charged metal cation/ligand pair.

Journal Article↗