Reconstruction of electron spectra from depth doses with adaptive regularization.

Electron spectral reconstruction of medical accelerators from measured depth doses is a practical method for providing the input initial phase space distribution at the patient surface that is required by Monte Carlo treatment planning systems. The posed inverse problem of spectral reconstruction is ill conditioned and this may lead to nonphysical oscillations in the reconstructed spectra. Use of a variational method of solution with a regularization technique removes the oscillations but tends to smooth the sharp (deltalike) energy peak that is a common feature in electron spectra generated by medical accelerators. Because the sharp peak contains a large percentage of the electrons in the spectrum, an accurate estimate of the peak width, height and position is critical to the success of the technique for spectrum reconstruction with regularization. We propose use of an adaptive regularization term as a special form of the general Tichonov regularization function. The variational method with the adaptive regularization term is applied to reconstruct electron spectra for the 6, 9, and 18 MeV electron beams of a Varian Clinac 2100C accelerator and proves to be a very simple, effective and accurate approach. Results using this variational method with adaptive regularization almost perfectly reconstruct electron spectra from depth dose distributions.

Electrons↗

Regularization of inverse planning for intensity-modulated radiotherapy.

The performance of a variational regularization technique to improve robustness of inverse treatment planning for intensity modulated radiotherapy is analyzed and tested. Inverse treatment planning is based on the numerical solutions to the Fredholm integral equation of the first kind which is ill-posed. Therefore, a fundamental problem with inverse treatment planning is that it may exhibit instabilities manifested in nonphysical oscillations in the beam intensity functions. To control the instabilities, we consider a variational regularization technique which can be applied for the methods which minimize a quadratic objective function. In this technique, the quadratic objective function is modified by adding of a stabilizing functional that allows for arbitrary order regularization. An optimal form of stabilizing functional is selected which allows for both regularization and good approximation of beam intensity functions. The regularized optimization algorithm is shown, by comparison for a typical case of a head-and-neck cancer treatment, to be significantly more accurate and robust than the standard approach, particularly for the smaller beamlet sizes.

Algorithms↗

L-curve analysis of radiotherapy optimization problems.

We attempt to select an optimal value of regularization parameter in the optimization problems for intensity-modulated radiotherapy which are solved using a variational regularization technique. We apply to inverse treatment planning the L-curve method which was developed to determine the regularization parameter in the discrete ill-posed problems. The L-curve method is based on finding the regularization parameter which minimizes the residual norm which is a measure of accuracy of fit and the solution norm which is a measure of smoothness of solution. The main idea of the L-curve method is to plot the smoothing norm as a function of the residual norm for all values of the regularization parameter. This characteristic curve has an L-shaped dependence and the optimal value of regularization parameter can be found at the "corner" of the L-curve. We plot the L-curves for the optimization problems which simulate prostate radiotherapy cancer treatment with intensity-modulated beams. Different numerical methods are applied to calculate the point of maximum curvature of the L-curves which is a criterion to locate the corner. We show that the point of maximum curvature can be located in a most robust way using a formula derived from the singular value decomposition analysis.

Algorithms↗

Angular correction in reconstruction of electron spectra from depth dose distributions.

Techniques for reconstruction of electron spectra from the depth-dose curves used to date have ignored the angular distribution of incident electrons scattered at large angles. The approximation adopted is to employ a database of monoenergetic depth-dose curves generated for normal incidence of electrons at the surface. This approximation is acceptable for direct electrons with small angular spread. However, electrons scattered from the treatment head and collimating system may have large average angles of incidence which affects the depth-dose distribution significantly at shallow depths by increasing energy deposition close to the surface. We show that ignoring the electron incident angular distribution leads to systematic errors in the low energy region of reconstructed electron spectra. We propose a simple 1-D model to correct for these systematic errors using only electron angular distribution at the central beam axis. This model provides reconstructed spectra in excellent agreement with Monte Carlo simulation in the low energy region.

Algorithms↗

Intensity and energy modulated radiotherapy with proton beams: variables affecting optimal prostate plan.

Inverse planning for intensity- and energy-modulated radiotherapy (IEMRT) with proton beams involves the selection of (i) the relative importance factors to control the relative importance of the target and sensitive structures, (ii) an appropriate energy resolution to achieve an acceptable depth modulation, (iii) an appropriate beamlet width to modulate the beam laterally, and (iv) a sufficient number of beams and their orientations. In this article we investigate the influence of these variables on the optimized dose distribution of a simulated prostate cancer IEMRT treatment. Good dose conformation for this prostate case was achieved using a constellation of I factors for the target, rectum, bladder, and normal tissues of 500, 50, 15, and 1, respectively. It was found that for an active beam delivery system, the energy resolution should be selected on the basis of the incident beams' energy spread (sigmaE) and the appropriate energy resolution varied from 1 MeV at sigmaE = 0.0 to 5 MeV at sigmaE= 2.0 MeV. For a passive beam delivery system the value of the appropriate depth resolution for inverse planning may not be critical as long as the value chosen is at least equal to one-half the FWHM of the primary beam Bragg peak. Results indicate that the dose grid element dimension should be equal to or no less than 70% of the beamlet width. For this prostate case, we found that a maximum of three to four beam ports is required since there was no significant advantage to using a larger number of beams. However for a small number (< or = 4) of beams the selection of beam orientations, while having only a minor effect on target coverage, strongly influenced the sensitive structure sparing and normal tissue integral dose.

Algorithms↗

Reconstruction of electron spectra using singular component decomposition.

Reconstruction of electron spectra of medical accelerators from measured depth dose distributions is an attractive tool for commissioning of a Monte Carlo treatment planning system. However, the reconstruction method is an inverse radiation transport problem which is poorly conditioned, in the sense it may become unstable due to small perturbations in the input data. Predicting the sharp (delta-like) peak in the electron spectrum provides an additional challenge for the numerical reconstruction technique. To improve efficiency and robustness of the reconstruction technique, we developed an algorithm based on a separation of the electron spectrum into singular and regular components. We approximate the singular peak of the spectrum by a narrow weighted Gaussian function. The parameters of this Gaussian function are sought using only the fall-off and toe regions of the depth-dose curve. Analytical representation of the spectral peak by a Gaussian has benefit since only one weight and the mean and variance must be derived from the depth-dose curve instead of multiple spectra weights. The regular part of the spectrum is reconstructed from the residual depth-dose distribution using a variational method combined with a regularization technique to avoid the nonphysical oscillations. The effectiveness of the method is demonstrated by comparing predictions to "benchmark" spectra and depth-dose distributions from Monte Carlo simulation of medical accelerators.

Algorithms↗