PubMed Health⌕ Search

Biomedical subjects

Alexey Shvarev

Publications and source records attributed to Alexey Shvarev.

8 recordsLinked to original sources

Photoresponsive ion-selective optical sensor.

A novel concept of photoresponsive ion-selective optical sensor is described. Photochemical reactions can be utilized to generate and control ion fluxes in an ion-selective optode in the same manner as nonequilibrium electrochemical methods have been used in ion-selective electrodes. In contrast to their equilibrium counterparts, the photoresponsive pH-selective ion optodes are sensitive to both the buffer capacity of the sample and activity of hydrogen ions. Active optical probes are especially attractive for intracellular applications because they can be fabricated as submicron-sized beads. Common optical techniques, such as fluorescence microscopy and flow cytometry, can be combined with active ion probes with only minor modification of the existing experimental setup.

Journal Article↗

Selective coulometric release of ions from ion selective polymeric membranes for calibration-free titrations.

Coulometry belongs to one of the few known calibration-free techniques and is therefore highly attractive for chemical analysis. Titrations performed by the coulometric generation of reactants is a well-known approach in electrochemistry, but suffers from limited selectivity and is therefore not generally suited for samples of varying or unknown composition. Here, the selective coulometric release of ionic reagents from ion-selective polymeric membrane materials ordinarily used for the fabrication of ion-selective electrodes is described. The selectivity of such membranes can be tuned to a significant extent by the type and concentration of ionophore and lipophilic ion-exchanger and is today well understood. An anodic current of fixed magnitude and duration may be imposed across such a membrane to release a defined quantity of ions with high selectivity and precision. Since the applied current relates to a defined ion flux, a variety of non-redox active ions may be accurately released with this technique. In this work, the released titrant's activity was measured with a second ionophore-based ion-selective electrode and corresponded well with expected dosage levels on the basis of Faraday's law of electrolysis. Initial examples of coulometric titrations explored here include the release of calcium ions for complexometric titrations, including back titrations, and the release of barium ions to determine sulfate.

Calcium↗

Calcium pulstrodes with 10-fold enhanced sensitivity for measurements in the physiological concentration range.

Ion-selective electrodes ideally operate on the basis of the Nernst equation, which predicts less than 60- and 30-mV potential change for a 10-fold activity change of monovalent and divalent ions measured at room temperature, respectively. Typical concentration ranges in extracellular fluids are quite narrow for the electrolytes of key importance. A range of 2.2-2.6 mM for calcium ions, for instance, translates into just a 2.2-mV potential change. The direct potentiometric measurement of physiological electrolytes is certainly possible with direct potentiometry and is done routinely in clinical analyzers and handheld measuring devices. It places, however, strong demands on the precision of the reference electrode and requires careful temperature control and frequent calibration runs. In this paper, a robust 10-20-fold sensitivity enhancement for calcium measurements is attained by departing from the classical response mechanism and operating in a non-Nernstian response mode. Stable and reproducible super-Nernstian responses of these so-called pulstrodes in a narrow calcium activity range can be controlled by instrumental means in good agreement with theory. The potentials may be measured during a galvanostatic excitation pulse (mode I) or immediately after it (mode II), under open-circuit conditions. Subtraction of the potentials, sampled at different times during a single pulse, allows one to obtain a sensitive differential peak-shaped signal at a critical and fully adjustable analyte activity range. Calcium pulstrodes based on the diamide ionophore AU-1 were characterized and applied to the measurement in model physiological liquids. Super-Nernstian responses exceeding 700 mV/decade were observed in a physiological range of calcium concentration. Such remarkable sensitivity of the pulstrodes, complemented with the well-documented high selectivity of these potentiometric sensors, may provide a significant increase in the accuracy and precision of electrolyte measurements in clinical analysis.

Biosensing Techniques↗

Response characteristics of a reversible electrochemical sensor for the polyion protamine.

We describe here in detail the first reversible electrochemical sensors for the polyion protamine. Potentiometric sensors were proposed in recent years, mainly for the determination of the polyions heparin and protamine. Such potentiometric polyion sensors functioned on the nonequilibrium extraction of polyions into a hydrophobic membrane phase via ion pairing with lipophilic ion exchangers. This made it difficult to design sensors that operate in a truly reversible fashion. The reversible sensors described here utilize the same basic response mechanism as their potentiometric counterparts, but the processes of extraction and ion stripping are now fully controlled electrochemically. Spontaneous polyion extraction is avoided by using membranes containing highly lipophilic electrolytes that possess no ion-exchange properties. Reversible extraction of polyions is induced if a constant current pulse of fixed duration is applied across the membrane, followed by a baseline potential pulse. The key theoretical response principles of this new class of polyion sensors are discussed here and compared to those of its classical potentiometric counterpart. The electrochemical sensing system is characterized in terms of optimal working conditions, membrane composition, selectivity, and influence of sample stirring and organic-phase diffusion coefficient on the response characteristics. Excellent potential stability and reversibility of the sensors are observed, and measurements of heparin concentration in whole blood samples via protamine titration are demonstrated.

Biosensing Techniques↗

Pulstrodes: triple pulse control of potentiometric sensors.

Ion-selective electrode membranes based on hydrophobic materials doped with chemically selective host molecules are an attractive sensing technology but normally suffer from a limited sensitivity, given by the Nernst equation, and a direct reliance on the reference electrode potential, which makes miniaturization difficult. These fundamental problems are addressed here by imposing a multipulse electrochemical excitation signal onto ion-selective membranes that lack ion-exchange properties. Current pulses are responsible for the generation of ion fluxes in the direction of the membrane, which give reproducible super-Nernstian response slopes that originate from depletion processes at the membrane surface. Membranes may also be measured at zero current after this pulse, giving super-Nernstian response regions at lower concentrations. Difference potentials obtained from subsequent pulses give about 10-fold higher sensitivities than predicted on the basis of the Nernst equation.

Biosensing Techniques↗

Reversible electrochemical detection of nonelectroactive polyions.

Selective extraction principles for the recognition of nonelectroactive polyions such as heparin and protamine exist, but the high ionic valency renders the extraction process irreversible. A response principle for the reversible detection of such polyions is proposed here. The extraction of the polyionic analyte to the membrane and its subsequent back-extraction is now controlled electrochemically. The principle is established with a protamine electrode, and excellent stability and reproducibility are demonstrated. This method has important implications for the design of chemical recognition principles for polyionic analytes.

Calibration↗

Pulsed galvanostatic control of ionophore-based polymeric ion sensors.

This paper describes a pulsed galvanostatic technique to interrogate ion-selective electrodes (ISEs) with no intrinsic ion-exchange properties. Each applied current pulse is followed by a longer baseline potential pulse to regenerate the phase boundary region of the ion-selective membrane. The applied current fully controls the magnitude and sign of the ion flux into the membrane, thus offering instrumental control over an effect that has become very important in ion-selective electrode research in recent years. The resulting chronopotentiometric response curves essentially mimic traditional ISE behavior, with apparently Nernstian response slopes and selectivities that can be described with the Nicolsky equation. Additionally, the magnitude and sign of the current pulse may be used to tune sensor selectivity. Perhaps most important, however, appears to be the finding that the extent of concentration polarization near the membrane surface can be accurately controlled by this technique. A growing number of potentiometric techniques are starting to make use of nonequilibrium principles, and the method introduced here may prove to be very useful to advance these areas of research. The basic characteristics of this pulsed galvanostatic technique are here evaluated with plasticized poly(vinyl chloride) membranes containing the sodium-selective ionophore tert-butyl calix[4]arene tetramethyl ester and a lipophilic inert salt.

Electric Conductivity↗