PubMed Health⌕ Search

Biomedical subjects

Alexia L McKnight

Publications and source records attributed to Alexia L McKnight.

2 recordsLinked to original sources

MR elastography of breast cancer: preliminary results.

OBJECTIVE: Motivated by the long-recognized value of palpation in detecting breast cancer, we tested the feasibility of a technique for quantitatively evaluating the mechanical properties of breast tissues on the basis of direct MR imaging visualization of acoustic waves. SUBJECTS AND METHODS: The prototypic elasticity imaging technique consists of a device for generating acoustic shear waves in tissue, an MR imaging-based method for imaging the propagation of these waves, and an algorithm for processing the wave images to generate quantitative images depicting tissue stiffness. After tests with tissue-simulating phantom materials and breast cancer specimens, we used the prototypic breast MR elastography technique to image six healthy women and six patients with known breast cancer. RESULTS: Acoustic shear waves were clearly visualized in phantoms, breast cancer specimens, healthy volunteers, and patients with breast cancer. The elastograms of the tumor specimens showed focal areas of high shear stiffness. MR elastograms of healthy volunteers revealed moderately heterogeneous mechanical properties, with the shear stiffness of fibroglandular tissue measuring slightly higher than that of adipose tissue. The elastograms of patients with breast cancer showed focal areas of high shear stiffness corresponding to the locations of the known tumors. The mean shear stiffness of breast carcinoma was 418% higher than the mean value of surrounding breast tissues. CONCLUSION: The results confirm the hypothesis that the prototypic breast MR elastographic technique can quantitatively depict the elastic properties of breast tissues in vivo and reveal high shear elasticity in known breast tumors. Further research is needed to evaluate the potential applications of MR elastography, such as detecting breast carcinoma and characterizing suspicious breast lesions.

Adult↗

Motion-correction techniques for standing equine MRI.

Magnetic resonance imaging (MRI) of the distal extremities of the standing, sedated horse would be desirable if diagnostic quality images could be obtained. With the availability of extremity and special purpose magnet designs on the market, a system to safely accommodate the standing horse may gain increasing popularity. This paper considers the issue of motion that will need to be addressed to achieve successful, diagnostic quality images. The motion of the carpus and tarsus of five standing, sedated horses was quantified. The obtained motion records were then used to induce motion in cadaveric joint specimens during several MRI scans. The measured dorsal-palmar/plantar, medial-lateral, and proximal-distal random wobbling motions in the standing sedated horse were several centimeters in magnitude and generated severe motion-artifacts during axial MRI of the cadaveric specimens. Two retrospective motion-correction techniques (autocorrection and navigator-based adaptive correction) were used to correct the corrupted images. The motion artifacts were nearly eliminated with the use of both techniques in series. Although significant hurdles remain, these results suggest promise for allowing diagnostic quality MRI of the carpus and tarsus in the standing horse.

Animals↗