PubMed Health⌕ Search

Biomedical subjects

Alfredo O Rodríguez

Publications and source records attributed to Alfredo O Rodríguez.

3 recordsLinked to original sources

Magnetron surface coil for brain MR imaging.

A resonator surface coil was developed for magnetic resonance imaging of the brain and tested on a clinical imager. This resonator design was based on the cavity magnetron with an 8 slot-and-hole configuration. High-resolution brain images were obtained from a water-filled phantom and from a healthy volunteer brain. To compare coil performance, SNR-vs.-depth plots were computed for a single-loop coil and the magnetron prototype from phantom images. These experimentally acquired profiles show an important improvement in SNR. Thus, the magnetron surface coil can generate brain images with a high resolution and penetration capacity. The high sensitivity of this coil makes it a good candidate to be used in multicoil imaging sequences.

Brain↗

Improved SNR of phased-array PERES coils via simulation study.

A computational comparison of signal-to-noise ratio (SNR) was performed between a conventional phased array of two circular-shaped coils and a petal resonator surface array. The quasi-static model and phased-array optimum SNR were combined to derive an SNR formula for each array. Analysis of mutual inductance between coil petals was carried out to compute the optimal coil separation and optimum number of petal coils. Mutual interaction between coil arrays was not included in the model because this does not drastically affect coil performance. Phased arrays of PERES coils show a 114% improvement in SNR over that of the simplest circular configuration.

Computer Simulation↗

Quantification of vena cava blood flow with half Fourier echo-planar imaging.

BACKGROUND: Human hemodynamics occurs in very short periods of time. To quantify blood flow under these circumstances, a fast-scan imaging technique is required. Echo-planar imaging can be a good candidate because it is able to acquire images in <50-100 msec. An imaging scheme with these properties can produce real-time images as well as overcome motion artifacts such as blurring and ghosting, which alter image quality. Additionally, echo-planar imaging does not require a calibration protocol to perform flow experiments in the human cardiovascular system. Consequently, echo-planar imaging appears to be the best imaging tool available to quantify blood flow in the vena cava. From a clinical point of view, echo-planar imaging has become a widespread commodity to produce magnetic resonance images in real-time. METHODS: Flow-encoded half Fourier echo-planar imaging is proposed to determine blood flow in the arteries. This flow sequence was used to investigate vena cava blood flow in healthy volunteers and compared with other diagnostic imaging modalities. RESULTS: Two-dimensional flow maps were obtained by using the two components (sine and cosine images) resulting from the flow-encoded echo-planar imaging sequence. Velocity profiles of vena cava of two healthy volunteers were calculated from the previous bidimensional blood flow maps. CONCLUSIONS: We proved that real-time flow imaging of the cardiovascular system can be achieved with flow-encoded echo-planar imaging and a partial Fourier method. It is possible to quantify blood flow in the superior vena cava in humans. We believe that this imaging tool might offer relevant anatomic and physiologic information of the vena cava as well as of the cardiovascular system.

Echo-Planar Imaging↗