PubMed Health⌕ Search

Biomedical subjects

Ali Ghanbari Saghseloo

Publications and source records attributed to Ali Ghanbari Saghseloo.

2 recordsLinked to original sources

Spectrophotometric and AAS determination of trace amounts of cobalt after preconcentration by using alpha-benzilmonoxime-microcrystalline naphthalene.

The formed cobalt-a-benzilmonoxime complex was adsorbed onto microcrystalline naphthalene. Then it was determined by zero and first derivative spectrophotometry and by atomic absorption spectrophotometry (AAS) after dissolving into chloroform and methylisobutylketone (MIBK), respectively. Under optimum conditions, cobalt in the range of 1.0 - 20.0, 0.4 - 30.0 and 2.5 - 50.0 microg could be determined by spectrophotometry, first derivative spectrophotometry and AAS method, respectively. By the method, a preconcentration factor equal to approximately 30 for cobalt was obtained. The effect of diverse ions on the determination of 5.0 microg cobalt was also studied. The method was successfully applied to some pharmaceuticals and synthetic alloy samples.

Benzyl Compounds↗

Second and first-derivative spectrophotometry for efficient simultaneous and individual determination of palladium and cobalt using 1-(2-pyridylazo)-2-naphthol in sodium dodecylsulfate micellar media.

1-(2-Pyridylazo)-2-naphthol (PAN) has been used for the simultaneous and individual determination of palladium and cobalt at trace levels. PAN complexes of palladium and cobalt at neutral pH form green-color neutral complexes, which are soluble in aqueous SDS micellar media. Under optimum conditions, calibration graphs for individual determinations by zero and first-derivative spectrophotometry, and also for simultaneous determinations by second-derivative spectrophotometry were obtained. A zero-crossing method using second-derivative spectrophotometry at 628 or 578 and 614 nm, respectively, for cobalt and palladium was used for simultaneous determinations. The method is able to determine the cobalt-to-palladium ratio, 5:1 to 1:10 (Wt/Wt), accurately. The accuracy and reproducibility of the determination method for various known amounts of cobalt and palladium in their binary mixtures were tested. The effects of diverse ions on the determination of cobalt and palladium to investigate the selectivity of the method were also studied. The recommended procedures were applied to a synthetic binary alloy, cobalt in vitamin B12 and B-complex ampoules, a Co2O3-Co3O4 laboratorial chemical mixture, some synthetic cobalt-alloy samples, a Pd-charcoal catalyst, and some synthetic palladium alloys.

Alloys↗