PubMed Health⌕ Search

Biomedical subjects

Ali Sasmaz

Publications and source records attributed to Ali Sasmaz.

4 recordsLinked to original sources

Twenty-two years without anticoagulation with metallic heart valve.

Anticoagulation is essential and vital for mechanical heart valves to prevent lethal complications such as valve thrombosis and systemic embolism. Herein, we reported the third longest survived case with a metallic aortic valve without anticoagulation and reviewed the role of anticoagulation in mechanical heart valves.

Adult↗

The effects of mobile phones on pacemaker function.

OBJECTIVES: The electromagnetic field generated by different systems have well-recognized adverse effects on pacemaker functions. The aim of this study is to evaluate the adverse effects of mobile phones on pacemaker functions. METHODS AND RESULTS: A total of 679 patients with permanent pacemakers were enrolled in this study. The study was performed in two steps. Pacemaker lead polarity was unipolar in the first step and bipolar in the second step. Pacemaker sensitivity was first at nominal values, it was then reduced to the minimal value for that pacemaker and tested again. Two mobile phones were symmetrically located on both sides of the pacemaker pocket with the antennas being equidistant at 50, 30, 20 and 10 cm and in close contact with the pocket. The tests were performed when both mobiles were opened, on stand-by, were receiving a call, during the call and were closed. Thirty-seven patients with pacemakers were adversely affected (5.5%) (33 VVI-R pacemakers were converted to asynchronous mode, and 3 were inhibited, 1 DDD-R pacemaker developed ventricular triggering). When the lead polarity was unipolar, the rate of adverse effect was higher when compared to the bipolar state (4.12% and 1.40%, p<0.01). The increase in sensitivity was not an independent factor on the rate of being affected (p>0.05). The rate of observing an adverse effect increased as the pacemaker got older (p<0.05). CONCLUSIONS: Mobile phones might have adverse effects on pacemaker functions under certain conditions. This does not result in any symptoms other than the inhibition of pacemakers, and pacemaker functions return to normal when the mobile phones are removed away from the patient.

Aged↗

Increased dispersion of refractoriness in patients with atrial fibrillation in the early postoperative period after coronary artery bypass grafting.

INTRODUCTION: Increased atrial effective refractory period (AERP) dispersion is well correlated with vulnerability to atrial fibrillation (AF). However, the preoperative electrophysiologic characteristics of atrial abnormalities that may play an important role in the development of AF postoperatively in patients with coronary artery bypass grafting (CABG) have not been investigated in detail. METHODS AND RESULTS: Fifty-six consecutive patients who underwent CABG were enrolled in this study. Eighteen patients (14 men and 4 women; mean age 57.7 +/- 5.2 years) with AF in the early postoperative period and 38 patients (28 men and 10 women; mean age 56.3 +/- 6.4 years) without AF were compared with regard to preoperative clinical, echocardiographic, angiographic, and electrophysiologic parameters. Preoperative PA interval and AERP dispersion values were higher (P < 0.05) in patients who developed AF in the early postoperative period. PA interval (P < 0.05, odds ratio = 1.64, 95% confidence interval 1.17-2.30), AERP in the high right atrium (AERP(HRA); P < 0.05, odds ratio = 0.94, 95% confidence interval 0.91-0.97), AERP in the right posterolateral atrium (AERP(RPL); P < 0.05, odds ratio = 0.79, 95% confidence interval 0.63-0.98), AERP in the distal coronary sinus (AERP(DCS); P < 0.05, odds ratio = 0.84, 95% confidence interval 0.74-1.02), and AERP dispersion (P < 0.001, odds ratio = 1.29, 95% confidence interval 1.12-1.47) were independently related to post-CABG AF in univariate analysis. Increases in preoperative PA interval and AERP dispersion were found to be associated with a high risk for development of post-CABG AF. CONCLUSION: AERP dispersion is a suitable electrophysiologic indicator for atrial vulnerability. The presence of increased preoperative AERP dispersion and PA interval may indicate patients at high risk for development of AF in the early postoperative period after coronary artery bypass grafting.

Atrial Fibrillation↗