PubMed Health⌕ Search

Biomedical subjects

Alina Plenis

Publications and source records attributed to Alina Plenis.

3 recordsLinked to original sources

Sensitive quantification of chosen drugs by reversed-phase chromatography with electrochemical detection at a glassy carbon electrode.

Reversed-phase-high-performance liquid chromatographic method with electrochemical detection has proven to be a highly sensitive and selective method for determination of trace components in complex biological samples, and the electrochemical detector becomes an important alternative tool to ultraviolet and fluorescence detectors. A rapid and sensitive method for the accurate determination of metoclopramide, hydrochlorothiazide, imipramine and diclofenac in serum or plasma samples is described. The method is based on liquid-liquid extraction. The compounds were separated on C-18 column as stationary phase with a different binary mixture as mobile phase. Proposed method was validated with respect to specificity, linearity range, limit of detection and quantitation, precision, accuracy and successfully applied in a pharmacokinetic studies.

Carbon↗

Determination of diclofenac in plasma by high-performance liquid chromatography with electrochemical detection.

A reversed-phase high-performance liquid chromatographic method with electrochemical detection for the quantitative determination of diclofenac potassium in plasma was developed. Naproxen was used as the internal standard. The drug and internal standard were isolated from plasma by extraction with dichloromethane and 2 M hydrochloric acid. Chromatographic separation was performed on a C18 column with methanol-water (68:32, v/v) adjusted to pH 3.2 with phosphoric acid as mobile phase. The oxidation potential for detection was established by constructing a voltammogram for diclofenac. The quantification limit for diclofenac in plasma was 5 ng mL(-1). Linearity of the method was confirmed in the range 5-2000 ng mL(-1), correlation coefficient 0.9998. Within-day relative standard deviations (RSDs) ranged from 0.66 to 14.00% and between-day RSDs from 0.59 to 15.78%. The method was successfully applied for the determination of pharmacokinetic parameters after ingestion of a 50 mg dose of diclofenac. Studies were performed on 18 healthy volunteers of both sexes.

Adult↗

Comparative evaluation between capillary electrophoresis and high-performance liquid chromatography for the analysis of florfenicol in plasma.

A capillary electrophoresis (CE) and a reversed phase high-performance liquid chromatography (RP-HPLC) method with UV detection have been developed for florfenicol analysis in plasma samples. The suitabilities of both methods for quantitative determination of florfenicol were approved through validation specification, such as linearity, precision, selectivity, accuracy, limit of detection and quantification. The capillary electrophoresis (CE) and high-performance liquid chromatography (HPLC) assay were compared by analyzing a series of plasma samples containing florfenicol in different concentrations using the two methods. The extraction procedure is simple and no gradient elution or derivatization is required. Furthermore, the analysis time of the CE method is two times shorter than the respective parameter in HPLC and solvent consumptions is considerably lower. The calibration curve were linear to at least 0.05-10 microg/ml (r = 0.9998) and 0.1-10 microg/ml (r = 0.9998) for CE and HPLC, respectively. The separation efficiency are good for both methods. The detection limits for florfenicol were 0.015 microg/ml with CE and 0.03 microg/ml with HPLC and CE method gave lower value, even though UV detector was applied in the both cases. The both methods were selective, robust and reliable quantification of florfenicol and can be useful for clinical and biomedical investigations.

Anti-Bacterial Agents↗