Donor tricuspid annuloplasty during orthotopic heart transplantation: long-term results of a prospective controlled study.

BACKGROUND: Development of tricuspid regurgitation after orthotopic heart transplantation can cause heart failure along with renal and hepatic impairment and portends a poor prognosis. If tricuspid regurgitation causes significant symptoms, tricuspid valve repair or replacement is often required. This study was designed to study the effects of prophylactic tricuspid valve annuloplasty (TVA) during orthotopic heart transplantation on long-term survival, renal function, and amount of tricuspid regurgitation. METHODS: Between April 1997 and March 1998, 60 patients (aged 18 to 70 years; 22 female) randomly received either standard bicaval orthotopic heart transplantation (group STD; n = 30) or bicaval orthotopic heart transplantation with DeVega TVA (group TVA; n = 30). Tricuspid valve annuloplasty was performed on the donor heart before implantation using pledgeted 2-0 polypropylene and sized to an annulus of 29 mm. Echocardiographic measurements, laboratory values, and hemodynamics were obtained prospectively and reviewed by an independent data analyst. RESULTS: Follow-up of patients as of December 2003 was complete. Although there was a perioperative mortality advantage in group TVA, there was no difference between groups in long-term survival. At the end of the study, however, there was a statistical difference (group STD versus group TVA, p < 0.05) with regard to cardiac mortality (7 of 30 versus 3 of 30), average amount of tricuspid regurgitation (1.5 +/- 1.3 versus 0.5 +/- 0.4), percentage of patients with 2+ or greater tricuspid regurgitation (34% versus 0%), serum creatinine (2.9 +/- 2.0 versus 1.8 +/- 0.7), and difference in serum creatinine over baseline (2.0 +/- 2.1 versus 0.7 +/- 0.8). CONCLUSIONS: Prophylactic DeVega TVA of the donor heart is durable and decreases the incidence of cardiac-related mortality and tricuspid regurgitation after orthotopic heart transplantation. In addition, there is improved protection of renal function. Considering the ease and safety of TVA and its advantages, it should be performed as a routine adjunct to orthotopic heart transplantation.

Adolescent↗

A one-year comparison of prophylactic donor tricuspid annuloplasty in heart transplantation.

BACKGROUND: The bicaval technique for orthotopic heart transplantation decreases the incidence of tricuspid valve regurgitation when compared with the standard biatrial technique. This study was designed to study the effects of prophylactic tricuspid valve annuloplasty during bicaval orthotopic heart transplantation on survival, renal function, and amount of tricuspid valve regurgitation. METHODS: Between April 1997 and March 1998, 60 patients (age 18 to 70 years, 22 women) randomly received either bicaval orthotopic heart transplantation (n = 30) or bicaval orthotopic heart transplantation with DeVega tricuspid valve annuloplasty (n = 30). Tricuspid valve annuloplasty was performed on the donor heart before implantation using pledgeted 2-0 polypropylene suture and sized to an annulus of 29 mm. Echocardiographic variables, laboratory values, and hemodynamics were obtained prospectively and reviewed by an independent data analyst. RESULTS: Intraoperatively, the group undergoing tricuspid valve annuloplasty had a shorter reperfusion time (46 +/- 29 minutes versus 65 +/- 48 minutes; p < 0.05) and higher mean pulmonary artery to central venous pressure difference (11.8 +/- 3.7 mm Hg versus 15.3 +/- 4.1 mm Hg; p = 0.001). Additional differences between the two groups included early mortality from donor dysfunction (4 of 30 patients versus 0 of 30 patients; p < 0.05), amount of tricuspid valve regurgitation at 1 year (1.3 +/- 1.0 versus 0.2 +/- 0.3; p < 0.05), and percentage of patients with 2+ or greater tricuspid valve regurgitation (34% versus 0%; p < 0.05). CONCLUSIONS: Tricuspid valve annuloplasty of the donor heart before bicaval orthotopic heart transplantation improves immediate donor heart function as demonstrated by better right ventricular performance, lower perioperative mortality, and shorter reperfusion times. At 1 year, there is less tricuspid valve regurgitation but no difference in renal function. Considering the ease and safety of tricuspid valve annuloplasty and its advantages, it should be performed as a routine adjunct with bicaval orthotopic heart transplantation.

Adult↗