Development of a soft tissue seal around bone-anchored transcutaneous amputation prostheses.

Conventional amputation prosthetics are problematic because they rely on the stump-socket interface for attachment. Intraosseous transcutaneous amputation prostheses (ITAP) could solve these problems; however they rely on the integrity of the soft tissue-implant interface as a barrier to exogenous agents, and in the prevention of downgrowth and marsupilisation. We have used an in vivo animal model to study the soft tissue interfaces around bone-anchored transcutaneous implants. We hypothesise that by facilitating and increasing the area of dermal attachment to the implant epithelial down-growth will be reduced. A flange with a series of 24, 0.7 mm holes positioned immediately below the epithelium was used to increase dermal attachment. This significantly reduced downgrowth and optimised the integrity of the collagenous tissue-implant interface at the dermal level. We postulate that the flange reduces relative interfacial movement at the epithelium-implant interface by providing increased surface area for dermal tissue attachment. A tight seal at the dermal tissue level reduces the degree of downgrowth around ITAP, eliminating marsupilisation as a potential failure modality. Surface topography and coatings did not affect the degree of downgrowth or dermal attachment to straight or flanged implants. A significant negative correlation was observed between downgrowth and both epithelial and dermal attachment. This study shows that a soft tissue-implant interface capable of preventing downgrowth and marsupilisation can develop around a bone-anchored transcutaneous implant, given the incorporation of a porous flange positioned in the dermal tissues immediately below the epithelium. This will benefit applications where bone-anchored transcutaneous implants are used.

Alloys↗

Noninvasive Raman spectroscopy of human tissue in vivo.

We report the first transcutaneous Raman spectrum of human bone in vivo obtained at skin-safe laser illumination levels. The spectrum of thumb distal phalanx was obtained using spatially offset Raman spectroscopy (SORS), which provides chemically specific information on deep layers of human tissue, well beyond the reach of existing comparative approaches. The spectroscopy is based on collecting Raman spectra away from the point of laser illumination using concentric rings of optical fibers. As a generic analytical tool this approach paves the way for a range of uses including disease diagnosis, noninvasive probing of pharmaceutical products, biofilms, catalysts, paints, and in dermatological applications.

Biofilms↗

Novel assessment of bone using time-resolved transcutaneous Raman spectroscopy.

UNLABELLED: With fragility fractures increasing as the population ages, there is a need for improved means to estimate risk of fracture. We recorded Raman spectra of both the mineral and organic phases of bone transcutaneously, a technology with potential to enhance bone quality and fracture risk assessment. INTRODUCTION: The current "gold standard" assessment of bone quality is BMD determined by DXA. However, this accounts for only 60-70% of bone strength. X-rays are absorbed by the mineral phase of bone, whereas the organic phase remains essentially invisible; however, bone strength is critically dependent on both phases. We report, for the first time, a Raman spectroscopic technique that analyses both phases of bone beneath unbroken skin by eliminating spectral components of overlying tissues. MATERIALS AND METHODS: We used an 800-nm laser (1-kHz, 1-ps pulses) with a synchronized 4-ps Kerr gate with variable picosecond delay that effectively shuttered out photons from overlying tissues. We measured bone Raman spectra at a point 2 mm above the carpus from two mouse genotypes with extreme differences in bone matrix quality: wildtype and oim/oim (matched for age, sex, and weight). Typical depth was 1.1 mm. We repeated the measurements with overlying tissues removed down to bone. Oim/oim mice produce only homotrimeric collagen, which results in poorly mineralized bone tissue. RESULTS: The main spectral features were present from both bone phases. The spectral bands were in similar ratios when measured through the skin or directly from bone (in both genotypes). The band of the mineral phase (phosphate nu1) was smaller in oim/oim mice when measured directly from bone and through skin. The band associated with a particular vibrational mode of organic phase collagen (CH2 wag) showed a frequency shift between the genotypes. CONCLUSIONS: This novel technique allowed us, for the first time, to make objective transcutaneous spectral measurements of both the mineral and the organic phases of bones and distinguish between normal and unhealthy bone tissue. After further optimization, this technology may help improve fracture risk assessments and open opportunities for screening in anticipation of the predicted increase in fragility fractures.

Animals↗

Segmental variation in the in vitro cell metabolism of nucleus pulposus cells isolated from a series of bovine caudal intervertebral discs.

STUDY DESIGN: This study focuses on the association between cell metabolism and molecular matrix composition of nucleus pulposus (NP) tissue with spine level in sequential bovine caudal intervertebral discs. OBJECTIVE: To explore the hypothesis that the molecular composition of NP tissue and corresponding cell metabolism varies with caudal spine. A secondary hypothesis is tested that potential cellular differences are maintained after monolayer culture. SUMMARY OF BACKGROUND DATA: In articular cartilage, cell metabolism and molecular matrix composition are influenced by loading history. This may also be a feature of intervertebral discs in series. METHODS: NP cells (nonpooled or level pooled) were isolated from four sequential bovine caudal intervertebral discs (levels 3-4, 4-5, 5-6, and 6-7) and cultured in alginate beads immediately or following monolayer culture. Levels of 3H-TdR (proliferation) and 35SO4 (GAG synthesis) incorporation were determined from 14 animals. In a separate set of 6 animals, total content of water, DNA, collagen (and type), GAG (and type) were also determined. RESULTS: The rate of 3H-TdR and 35SO4 incorporation in freshly isolated NP cells increased nonlinearly from level 3-4 to 6-7 (P < 0.05). Monolayer cultured cells retained level-specific differences for 35SO4 and 3H-TdR incorporation similar to that of freshly isolated cells. GAG content and chondroitin sulfate proportion decreased distally (P < 0.05); however, total collagen and Type I proportion increased distally (P < 0.05). No significant differences in water or DNA content could be determined. CONCLUSIONS: The results support the hypothesis that level-specific differences in NP cell metabolism and molecular composition are dependent on spine level potentially reflecting subtle mechanical differences between levels. Retention of level-specific differences in monolayer may suggest a certain level of cell "programming." This may be important for cellular strategies to repairspecific sites of degeneration.

Animals↗

Role of hydroxyapatite coating in resisting wear particle migration and osteolysis around acetabular components.

The main problem facing the longevity of total joint replacements is wear particle-induced osteolysis, particularly around the acetabular component. Ovine Total Hip Replacement surgery was performed with roughened femoral heads in order to enhance wear debris generation in vivo. The resistance to aseptic loosening of acetabular components with different surface coatings was investigated. Implants remained in vivo for 1 year. Sheep were randomly assigned to one of six experimental groups where the acetabular cup was fixed utilising an: (a) cemented polyethylene acetabular cup, (b) metal backed grit blasted surface, (c) metal backed plasma sprayed titanium porous coating, (d) metal backed sintered beaded coating, (e) Hydroxyapatite (HA)-coated grit blasted surface (f) and HA-coated porous components. Ground Reaction Force (GRF) was used to asses the functional performance of the implants and data was collected pre-operatively and at 12, 24, 36 and 52 weeks post op. Wear debris generated was analysed and radiographs taken prior to preparation of thin sections. Fibrous tissue (FT) thickness and bone contact at 1 mm intervals along the acetabular bone-implant interface was calculated. GRF data demonstrated significant differences between experimental groups. In all groups there was an increase in the function of the hip after surgery and up to 24 weeks but thereafter the function of the group with the grit blasted surface reduced whereas the function of the other groups did not significantly change. Average wear particles generated were <1 microm in size. The cemented group demonstrated a significantly thicker average FT layer (2.69 mm) when compared with all other groups (p<0.05 in all cases) except the grit blasted group (1.56 mm). HA porous coated cups demonstrated significantly least fibrous tissue adjacent to its interface when compared with all other groups (cemented p<0.05, grit blasted p=0.029, porous p<0.05, sintered beads p<0.05 and HA grit blasted p<0.05). Significantly increased bone contact to HA-coated porous cups (73.33%) when compared with all groups was identified except HA-coated grit blasted cups where no significant difference was demonstrated. Radiographic signs of loosening were visible in all groups except the HA-coated porous group. Results demonstrated that HA porous coated acetabular components significantly enhanced bone ingrowth in the presence of wear particles, preventing their migration and reducing osteolysis. Non-HA-coated porous and sintered beaded components provided a more effective seal against the ingress of wear debris when compared with cemented cups.

Animals↗

Cross sectional area measurement of tendon and ligament in vitro: a simple, rapid, non-destructive technique.

The structural properties of tendons and ligaments are integral to their ability to function effectively in vivo and are determined from both the geometrical form and material properties. Many studies of tendon and ligament include a mechanical assessment of the structure in vitro. However, to determine the material properties of the constituent tissues it is necessary to measure cross-sectional area (CSA). Problems associated with this include damage to the structure, inaccurate values for non-uniform shapes, labour intensive techniques or requirement of expensive equipment. We describe a non-destructive technique for measurement of tendon and ligament CSA based on that of Race and Amis (J. Biomech. 29 (1996) 1207). The modified technique uses aqueous rapid curing alginate dental impression paste, digital photography and computerised image analysis. This technique is quick and simple to carry out and provides accurate values (within 0.8%) for CSA which are reproducible (coefficient of variation = 1.42%). The technique is non-destructive and can be used on specimens with an irregular shape.

Alginates↗

Effect of exercise on age-related changes in collagen fibril diameter distributions in the common digital extensor tendons of young horses.

OBJECTIVE: To determine whether specific treadmill exercise regimens would accelerate age-related changes in collagen fibril diameter distributions in the common digital extensor tendon (CDET) of the forelimbs of young Thoroughbreds. ANIMALS: 24 female Thoroughbreds. PROCEDURE: Horses were trained for 18 weeks (6 horses; short term) or 18 months (5 horses; long term) on a high-speed treadmill; 2 age-matched control groups (6 horses/group) performed walking exercise only. Horses were (mean +/- SD) 24 +/- 1 months and 39 +/- 1 months old at termination of the short-term and long-term regimens, respectively. Midmetacarpal CDET specimens were obtained and processed for transmission electron microscopy. Diameter and area of at least 1,000 collagen fibrils/specimen were measured by use of computerized image analysis. Mass-average diameter (MAD) of collagen fibrils and collagen fibril index were calculated for each horse. RESULTS: Collagen fibril MAD for the older horses was significantly less than that for the younger horses. Exercise did not significantly affect fibril diameter or distributions in either age group, and collagen fibril index did not differ significantly between groups. CONCLUSIONS AND CLINICAL RELEVANCE: Age-related reduction in collagen fibril MAD agreed with findings for other tendons and species. Training did not accelerate age-related change in the CDET in contrast to a reported decrease in collagen fibril MAD in the superficial digital flexor tendon of horses trained long term. Our results support the concept that the functionally distinct nature of the CDET and superficial digital flexor tendon in horses results in fundamentally different responses to high-speed exercise regimens.

Age Factors↗

Bone assessment of free-living red squirrels (Sciurus vulgaris) from the United Kingdom.

Metabolic bone disease has been reported in free-living red squirrels (Sciurus vulgaris) in the United Kingdom but the prevalence of this disease is unknown. In this study the bone quality of free-living red squirrels in the UK was assessed by radiology and bone densitometry. The study comprised 20 red squirrels found dead and submitted to the Zoological Society of London (UK) between 1997 and 1998, 10 were from the Isle of Wight (IoW), where gray squirrels (Sciurus carolinensis) are absent, and 10 were from Cumbria (Cu), where gray squirrels are present. Gray squirrels are considered potential competitors for red squirrels. Radiologic evaluation of humerus, femur, tibia, radius, and ilium revealed a slightly lower bone density and thinner cortices in red squirrels from the IoW when compared with those from Cu. Dual-energy X-ray absorptiometry was used to measure bone mineral content and density of the isolated right humerus and femur of 19 of the 20 red squirrels. The bone densitometry study reinforced the radiographic findings. The IoW specimens had lower bone mineral density values, although statistical significance (P<0.05) between animals from the IoW and Cu was only reached for the proximal epiphysis of the femur and between males from the IoW and males from Cu for the proximal epiphysis of the humerus. A highly positive correlation (r>0.94) was found when the bone mineral content and density between the femur and the humerus among groups and within each group were compared, showing a uniform level of mineralization between upper and lower limbs. These findings suggested generalized bone loss for the IoW red squirrels that may be compatible with some degree of osteopenia. Within the wide range of causes that lead to osteopenia, malnutrition (especially protein deficiency), calcium and copper deficiencies, and genetic factors remain as possible etiologies.

Absorptiometry, Photon↗

A novel technique for four-point bending of small bone samples with semi-automatic analysis.

The design of this system takes into account the following parameters: the effects of excessive strain; specimen depth and width; span-depth ratio; overhang; rate of loading; measuring displacement from the crosshead position; radius of contact points; and the distance between the contacts. The contacts are radius edges rather than cylinders, although this is not to be recommended for multiple cycles because of wear problems, it does make the system as stiff as possible (allowance is made for this compliance). Equations are presented that allow the surface stress and strain to be calculated for each time point semi-automatically. The combination of stiff contacts and strain equations based on crosshead position not mid-span displacement is novel, this allows rapid analysis with minimum intervention from the user and gives results that are in agreement with those in the literature.

Automation↗

Controlled induction of a pseudarthrosis: a study using a rodent model.

OBJECTIVES: This study aimed to test the hypothesis that under standardized mechanical and biologic conditions, the process of indirect bone repair in a rodent species could be manipulated to form a reproducible, atrophic, fibrous pseudarthrosis. DESIGN: The model used comprised a mid-diaphyseal, transverse osteotomy in the rat femur, stabilized via a precision miniature external fixator, a constant axial fixation stiffness being defined by a specific frame geometry. MAIN OUTCOME MEASUREMENTS: The repair process for both 0.5-mm and 3.0-mm gap osteotomies was characterized using radiography, dual-energy x-ray absorptiometry, histologic assessment of standardized longitudinal sections, and postmortem mechanical testing. RESULTS: Healing of the defect was highly reproducible, bone union being attained at around 5 weeks postoperatively with a 0.5-mm gap. Increasing the gap width to 3.0 mm resulted consistently in a pseudarthrosis. CONCLUSION: These two reproducible patterns of repair can now be used to elucidate the underlying molecular mechanisms controlling the extent and progression of connective tissue differentiation in indirect bone repair without the additional variable of a nonstandardized mechanical environment.

Absorptiometry, Photon↗

Evaluation of serum concentrations of biochemical markers of bone metabolism and insulin-like growth factor I associated with treadmill exercise in young horses.

OBJECTIVE: To evaluate changes in serum concentrations of biochemical markers of bone metabolism and insulin-like growth factor I (IGF-I) associated with treadmill exercise in young horses. ANIMALS: 12 two-year-old Thoroughbred mares. PROCEDURE: During a 20-week study period, 6 horses were exercised on a treadmill 3 times a week (exercise group) and 6 horses received walking exercise 6 days a week (controls). Serum concentrations or activity of biochemical markers and IGF-I were assessed biweekly. Bone mineral density and content of the first phalanx were measured by dual-energy X-ray absorbiometry (DEXA) on completion of the study. RESULTS: Compared with values in controls, bone mineral density and content were higher and serum concentrations of osteocalcin (a marker of bone formation) and the carboxy-terminal telopeptide of type I collagen (a marker of bone resorption; ICTP) were lower in exercised horses. Serum concentration and activity of the bone formation markers carboxy-terminal propeptide of type I collagen and bone-specific alkaline phosphatase (BAP) were not different between the 2 groups. Serum IGF-I concentration was lower in the exercise group, compared with control values; there was a significant correlation between change in IGF-I values and changes in osteocalcin, ICTP, and BAP values at the end of the study. CONCLUSIONS AND CLINICAL RELEVANCE: Treadmill exercise over 20 weeks induced adaptive changes in bones of 2-year-old Thoroughbreds; training appears to increase bone mineral density, thereby enhancing mechanical strength of bone, but decreases bone turnover. Results indicated an association between changes in serum IGF-I concentration and bone cell activity in horses.

Absorptiometry, Photon↗

Kerr-gated time-resolved Raman spectroscopy of equine cortical bone tissue.

Picosecond time-resolved Raman spectroscopy in equine cortical bone tissue is demonstrated. Using 400-nm pulsed laser excitation (1 ps at 1 kHz) it is shown that Kerr cell gating with a 4-ps window provides simultaneously time-resolved rejection of fluorescence and time-resolved Raman scatter enabling depth profiling through tissue. The Raman shifts are the same as those observed by conventional cw Raman spectroscopy using deep-red or near-infrared lasers. The time decay of Raman photons is shown to fit an inverse square root of time function, suggesting propagation by a diffusive mechanism. Using polystyrene behind a bone specimen, it is shown that the 400-nm laser light penetrates at least 0.31 mm below the surface of a fully mineralized bone tissue specimen and generates observable bone Raman scatter (approximately 415 to 430 nm) through most of this depth. These novel results demonstrate great promise for in vivo applications for studying diseased bone tissue, and ways to optimize the setup are discussed.

Animals↗