Neuronal ensemble control of prosthetic devices by a human with tetraplegia.

Neuromotor prostheses (NMPs) aim to replace or restore lost motor functions in paralysed humans by routeing movement-related signals from the brain, around damaged parts of the nervous system, to external effectors. To translate preclinical results from intact animals to a clinically useful NMP, movement signals must persist in cortex after spinal cord injury and be engaged by movement intent when sensory inputs and limb movement are long absent. Furthermore, NMPs would require that intention-driven neuronal activity be converted into a control signal that enables useful tasks. Here we show initial results for a tetraplegic human (MN) using a pilot NMP. Neuronal ensemble activity recorded through a 96-microelectrode array implanted in primary motor cortex demonstrated that intended hand motion modulates cortical spiking patterns three years after spinal cord injury. Decoders were created, providing a 'neural cursor' with which MN opened simulated e-mail and operated devices such as a television, even while conversing. Furthermore, MN used neural control to open and close a prosthetic hand, and perform rudimentary actions with a multi-jointed robotic arm. These early results suggest that NMPs based upon intracortical neuronal ensemble spiking activity could provide a valuable new neurotechnology to restore independence for humans with paralysis.

Adult↗

Long-term stimulation and recording with a penetrating microelectrode array in cat sciatic nerve.

We studied the consequences of long-term implantation of a penetrating microelectrode array in peripheral nerve over the time course of 4-6 mo. Electrode arrays without lead wires were implanted to test the ability of different containment systems to protect the array and nerve during contractions of surrounding muscles. Treadmill walking was monitored and the animals showed no functional deficits as a result of implantation. In a different set of experiments, electrodes with lead wires were implanted for up to 7 mo and the animals were tested at 2-4 week intervals at which time stimulation thresholds and recorded sensory activity were monitored for every electrode. It was shown that surgical technique highly affected the long-term stimulation results. Results between measurement sessions were compared, and in the best case, the stimulation properties stabilized in 80% of the electrodes over the course of the experiment (162 days). The recorded sensory signals, however, were not stable over time. A histological analysis performed on all implanted tissues indicated that the morphology and fiber density of the nerve around the electrodes were normal.

Action Potentials↗

Capabilities of a penetrating microelectrode array for recording single units in dorsal root ganglia of the cat.

The recording capability of a microelectrode array in the cat dorsal root ganglion (DRG) was studied in 11 acute experiments, 373 single, discriminable sensory units were recorded on 587 electrodes (0.64 units/electrode). Sensory action potentials as large as 1750 microV were obtained (mean=132 microV). These were comparable to literature reports of the best DRG extracellular recordings made with conventional electrodes. We were able simultaneously to activate and record over 50 discriminable, time-varying units from L6 and L7 DRGs during a cyclic ankle displacement. We also successfully recorded stable, phase dependent multiple sensory units with very little artifact or electromyographic (EMG) contamination during decerebrate walking. Thus, the array is capable of recording more effectively from more DRGs neurons than has been achieved by conventional recording techniques. The recording selectivity and stability of the array, coupled with the large number of neurons that can be recorded simultaneously, provide attractive features for better understanding sensorimotor control principles.