Electrical pacing counteracts intrinsic shortening of action potential duration of neonatal rat ventricular cells in culture.

Previous studies have demonstrated the relationship between the functional electrophysiological properties of cultured neonatal rat ventricular myocytes (NRVMs) and the ability of the substrate to induce and sustain arrhythmia. The goal of this study was to examine the effects of chronic pacing at a constant rate akin to that in vivo, on the functional electrophysiological properties of NRVM monolayers. Confluent NRVM monolayers grown on 20 mm diameter cover slips were left either unpaced or were stimulated at 3 Hz for the duration of the culture, and were optically mapped on days 4, 6, or 8. Action potential duration at 80% repolarization (APD80), conduction velocity (CV), and Kv4.3 (Ito) and NCX protein expression were measured. The effects of the excitation-contraction uncoupler 2,3-butadione monoxime (BDM) were also investigated. The 2 Hz APD80 of non-paced monolayers decreased significantly on days 6 (137.1+/-13.9 ms) and 8 (109.8+/-9.0 ms) compared with day 4 (197.0+/-11.8 ms), while that of paced monolayers did not (206.8+/-9.7, 209.1+/-9.2, and 210.6+/-9.9 ms, respectively). The 2 Hz CV of non-paced monolayers increased significantly on days 6 (26.0+/-1.6 cm/s) and 8 (26.5+/-1.0 cm/s) compared with day 4 (20.0+/-1.0 cm/s), while that of paced monolayers did not change significantly (26.0+/-2.0, 26.0+/-1.0, and 23.8+/-1.2 cm/s, respectively). The restitution curves of APD80 and CV of paced monolayers were also unchanging from days 4 through 8. Despite the unchanging APD80 and CV, a decrease in Kv4.3 expression and an increase in NCX expression were observed in paced compared with non-paced monolayers. Cessation of pacing or administration of BDM caused a reversal of phenotype back to that of non-paced monolayers. In summary, chronic electrical stimulation of confluent NRVM monolayers results in stabilization of APD80 and an advancement of the developmental rise of CV that is mediated by electromechanical coupling. These effects produce a steadier functional phenotype that may be beneficial for electrophysiological studies.

Action Potentials↗

Acute performance evaluation of a new ventricular automatic capture algorithm.

AIMS: This study evaluated the acute clinical performance of a new ventricular automatic capture algorithm developed to work with all lead types and pacing vectors. METHODS AND RESULTS: During regular pacemaker implant or replacement, AutoThreshold and manual threshold tests were performed in ventricular unipolar (UP) and bipolar (BP, if applicable) pacing using a customized external prototype INSIGNIA pacemaker. The success rate and accuracy of two different modes (commanded and ambulatory) of the automatic capture algorithm were used to evaluate the performance. Loss-of-capture events (two consecutive non-captured beats without backup pacing) were used to assess safety. Data of 53 patients (33 DDD/20 VVI) from four medical centres were analysed. Tested leads included 43 BP and 10 UP from nine manufacturers, and seven had electrodes with low polarization. The rate of successful commanded and ambulatory AutoThreshold tests was 96 and 94%, respectively, with an average absolute threshold difference compared with manual threshold of < 0.1 V at 0.4 ms (commanded 0.07 +/- 0.07 V and ambulatory 0.08 +/- 0.07 V). There was no significant difference in performance between UP/BP pacing, polarization, and lead type. No loss-of-capture event was observed. CONCLUSION: When successful, the ventricular automatic capture algorithm accurately determined pacing thresholds in either a UP or BP pacing configuration among all leads tested.

Adult↗