PubMed Health⌕ Search

Biomedical subjects

Ambuj Roy

Publications and source records attributed to Ambuj Roy.

5 recordsLinked to original sources

Aortic valve replacement with 31- and 33-mm mechanical prostheses: early results.

The mean aortic diameter of Indian adults is 25-31 mm, yet fewer than 1% of worldwide heart valve procedures involve a 31-mm aortic heart valve. Of the 72 large prosthetic aortic valves (31-mm) implanted in the Asia Pacific region during 2001-2003, 53 (74%) were implanted at our institution. This retrospective study was undertaken to assess early results and outcomes, on echocardiography and exercise testing, in patients who received large prosthetic aortic valves. From January 1997 through December 2002, 27 patients underwent isolated aortic valve replacement with 31-mm St. Jude Medical prostheses, and 4 patients underwent aortic valve replacement with 33-mm St. Jude Medical reversed mitral prostheses. These 31 patients were among 240 who underwent isolated aortic valve replacement at our institution during the same period. The preoperative, perioperative, and postoperative data were collected from case records and patient follow-up. Fifteen of the 31 patients underwent echocardiography and exercise testing at least 6 months after operation. There were no early deaths. No patient developed prosthetic valve endocarditis or paravalvular leak. One patient, who developed valve thrombosis as a result of noncompliance with the anticoagulation regimen, underwent thrombectomy and died during the early postoperative period, due to low cardiac output. There was no structural failure or anticoagulant-related hemorrhage. Postoperatively, the peak and mean gradients across the prostheses were low. The exercise performance of all the patients was good. These early favorable results need to be borne out by longer and more comprehensive study of larger groups.

Adolescent↗

Isolation of the left subclavian artery.

Two cases of isolation of the left subclavian artery from the aortic arch are reported for the rarity of this lesion. One patient was diagnosed clinically, the other after angiography. The isolated left subclavian artery was reimplanted in one patient. This rare anomaly has clinical and surgical relevance and should be diagnosed by diligent clinical and angiographic evaluation.

Angiography↗

An infant with "dying spells".

A 45-day-old infant presented with the unusual and intriguing symptom of episodic crying and loss of consciousness. The infant was discovered to have a vascular compression of the trachea by the innominate artery, almost serendipitously. He was cured of his symptoms by anterior suspension of the innominate artery.

Apnea↗

Use of Amplatzer duct occluder to close severely hypertensive ducts: utility of transient balloon occlusion.

BACKGROUND: The dividing line between a patent ductus arteriosus with severe but reversible pulmonary artery hypertension and an Eisenmenger duct remains elusive. Increasing experience with the Amplatzer duct occluder has made non-surgical closure of even large patent ductus arteriosus simple and safe. However, data on the use of this device in severly hypertensive ducti is sparse. METHODS AND RESULTS: There were six patients (2 males, 4 females), wherein transient ductal occlusion was done with an embolectomy balloon catheter. The post-occlusion hemodynamics along with overall clinical and hemodynamic assessment was used to decide the likelihood of benefit of closure and the choice of the device. In four of six patients of patent ductus arteriosus with severe pulmonary artery hypertension (pulmonary vascular resistance index> 8.0 U/m2) the duct was successfully closed using the Amplatzer duct occluder, while in two an Amplatzer ventricular septal defect occluder was used. CONCLUSIONS: Transient balloon occlusion is quite helpful for assessing patients with patent ductus arteriosus with severe pulmonary hypertension, and short-term non-invasive follow-up has shown this strategy to be safe and useful.

Adult↗