Real time in vivo non-invasive optical imaging using near-infrared fluorescent quantum dots.

RATIONALE AND OBJECTIVE: Deep-tissue optical imaging is of particular interest, as the equipment costs are lower than for competing technologies such as MRI. For this purpose, the development of novel contrast agents with near-infrared (NIR) fluorescence is especially important. We report on the use of NIR semiconductor nanocrystals in deep-tissue in vivo optical imaging. MATERIALS AND METHODS: Semiconductor nanocrystals of CdMnTe/Hg were grown in aqueous solution and then coated with bovine serum albumin (BSA). The nanocrystals were approximately 5 nm in diameter and have a broad fluorescence peak in the NIR (770 nm). Nanocrystals were injected either subcutaneously or intravenously into athymic NCR NU/NU and C3H/HENCR MTV mice and then excited with a spatially broad 633 nm source; the resulting fluorescence was captured with a sensitive CCD camera. RESULTS: We have demonstrated that the nanocrystals are a useful angiographic contrast agent for vessels surrounding and penetrating a murine squamous cell carcinoma in a C3H mouse. Preliminary assessment of the depth of penetration for excitation and emission was done by imaging a beating mouse heart, both through an intact thorax and after a thoracotomy. The temporal resolution associated with imaging the nanocrystals in circulation has been addressed, and the blood clearance for this contrast agent has also been measured. CONCLUSIONS: There was no significant photobleaching or degradation of the nanocrystals after an hour of continuous excitation. The stability of the nanocrystals together with the time resolution of the optical detection makes them particularly attractive candidates for pharmacokinetic imaging studies.

Animals↗

Functional optical detection based on pH dependent fluorescence lifetime.

BACKGROUND AND OBJECTIVES: Detection of possible alterations of physiological parameters (e.g., pH and temperature), resulting from malignant transformation of initially healthy tissue, can be a powerful diagnostic tool for earlier cancer detection. Such variations can be observed by comparing these parameters with those of healthy tissue surrounding the abnormality. Time-resolved spectroscopy of specifically targeted fluorescent labeled antibodies can be sensitive to such variations and provide a high resolution functional image of the region of interest. The goal of this study was to establish a forward experimental setup for calibration of the lifetime dependencies of near-IR fluorescent dyes on physiological parameters, and to develop analytical solutions, taking into account the effects of light propagation in turbid media (e.g., tissue), that was able to extract an original lifetime fluorescence signal from time-of-flight intensity distributions, measured in vivo from a deeply embedded live organ for further analysis. STUDY DESIGN/MATERIALS AND METHODS: Tissue-like phantoms with embedded fluorescent dyes and background optical properties simulating those of live tissues were designed and created. Fluorescence decay curves were measured for different fluorophore positions, and pH values. Those measurements were made with a system based on a time-correlated single photon counting (TCSPC) instrument and a tunable femtosecond Ti-Sapphire system built by our group. RESULTS: Decay curves were recorded for fluorophore depths of up to 5 mm and source-detector separation of 7 mm. It was shown that a forward model, based on the random walk theory, adequately described the experimental data. Measured pH dependencies of the fluorescence lifetime were characterized for two different dyes. CONCLUSIONS: Good correlation between experimental data and predictions of the theoretical model allows the use of close-form analytical solutions to separate the effects of photon time delays due to multiple scattering in tissues from the original intensity fluorescence time decay curve, determined by the fluorophore itself and its immediate surroundings. It is the latter dependence that can be diagnostically important. Experimentally obtained scaling between lifetime and a parameter of interest can be used in vivo to obtain a map of physiological parameter changes which can serve as a base for an in vivo specific diagnostic system.

Animals↗

In vivo quantitative three-dimensional localization of tumor labeled with exogenous specific fluorescence markers.

We introduce a diffused optical detection system based on the administration of a fluorophore-antibody conjugate to diseased tissue. The conjugate interacts with the antigens expressed by the diseased tissue, resulting in fluorescent labeling of the antigen. By combining an optical detection system with a reconstruction algorithm developed on the basis of the random-walk model, we were able to determine the position of the fluorophore (and, thus, of the diseased cells) in the tissue. We present three-dimensional reconstructions of the location of a fluorophore (FITC-fluorescein isothiocyanate) in the tongues of mice. Measurements were performed with the fluorophore embedded at various simulated depths. The simulations were performed with agarose-based gel slabs applied to the tongue as tissuelike phantoms. Reconstructed fluorophore locations agree well with the actual values.

Algorithms↗

Quantification of optical properties of a breast tumor using random walk theory.

For the first time we use a random walk methodology based on time-dependent contrast functions to quantify the optical properties of breast tumors (invasive ductal carcinoma) of two patients. Previously this theoretical approach was successfully applied for analysis of embedded objects in several phantoms. Data analysis was performed on distributions of times of flight for photons transmitted through the breast which were recorded in vivo using a time-domain scanning mammograph at 670 and 785 nm. The size of the tumors, their optical properties, and those of the surrounding tissue were reconstructed at both wavelengths. The tumors showed increased absorption and scattering. From the absorption coefficients at both wavelengths blood oxygen saturation was estimated for the tumors and the surrounding tissue.

Absorption↗

Analytical calculation of the mean time spent by photons inside an absorptive inclusion embedded in a highly scattering medium.

The mean time spent by photons inside a nonlocalized optically abnormal embedded inclusion has been derived analytically. The accuracy of the results has been tested against Monte Carlo and experimental data. We show that for quantification of the absorption coefficient of absorptive inclusions, a corrective factor that takes into account the size of the inclusion is needed. This finding suggests that perturbation methods derived for very small inclusions which are used in inverse algorithms require a corrective factor to adequately quantify the differential absorption coefficient of nonlocalized targets embedded in optically turbid media.

Biophysical Phenomena↗

Differential oblique angle spectroscopy of the oral epithelium.

Increasing evidence suggests that inflammation may contribute to the process of carcinogenesis. This is the basis of several clinical trials evaluating potential chemopreventive drugs. These trials require quantitative assessments of inflammation, which, for the oral epithelium, are traditionally provided by histopathological evaluation. To reduce patient discomfort and morbidity of tissue biopsy procedures, we develop a noninvasive alternative using diffuse reflectance spectroscopy to measure epithelial thickness as an index of tissue inflammation. Although any optical system has the potential for probing near-surface structures, traditional methods of accounting for scattering of photons are generally invalid for typical epithelial thicknesses. We develop a single-scattering theory that is valid for typical epithelial thicknesses. The theory accurately predicts a distinctive feature that can be used to quantify epithelial thickness given intensity measurements with sources at two different angles relative to the tissue surface. This differential measure approach has acute sensitivity to small, layer-related changes in scattering coefficients. To assess the capability of our method to quantify epithelial thickness, detailed Monte Carlo simulations and measurements on phantom models of a two-layered structure are performed. The results show that the intensity ratio maximum feature can be used to quantify epithelial thickness with an error less than 30% despite fourfold changes in scattering coefficients and 10-fold changes in absorption coefficients. An initial study using a simple two-source, four-detector probe on patients shows that the technique has promise. We believe that this new method will perform well on patients with diverse tissue optical characteristics and therefore be of practical clinical value for quantifying epithelial thickness in vivo.

Algorithms↗

Whole-body fluorescence lifetime imaging of a tumor-targeted near-infrared molecular probe in mice.

Fluorescence lifetime imaging can provide valuable diagnostic information relating to the functional status of diseases. In this study, a near-infrared (NIR) dye-labeled hexapeptide (abbreviated Cyp-GRD) was synthesized. In vitro, Cyp-GRD internalized in nonsmall cell lung cancer cells (A549) without observable cytotoxic or proliferative effects to the cells at a concentration up to 1x10(-4) M. Time-domain fluorescence intensity and lifetime imaging of Cyp-GRD injected into A549 tumor-bearing mice revealed that the probe preferentially accumulated in the tumor and the major excretion organs. The fluorescence lifetime of the conjugate at the tumor site was mapped, showing the spatial distribution of the lifetime related to its environment. Additionally, fluorescence intensity image reconstruction obtained by integrating the time-resolved intensities enabled the contrast ratios of tumor-to-kidney or liver in slices at different depths to be displayed. The mean lifetime was 1.03 ns for the tumor and 0.80 ns for the liver when averaging those pixels exhibiting adequate signal-to-noise ratio, showing the tumor had a higher lifetime average and reflecting the altered physiopathology of the tumor. This study clearly demonstrated the feasibility of whole-body NIR fluorescence lifetime imaging for tumor localization and its spatial functional status in living small animals.

Animals↗

Enhancement of hidden structures of early skin fibrosis using polarization degree patterns and Pearson correlation analysis.

The skin of athymic nude mice is irradiated with a single dose of x-ray irradiation that initiated fibrosis. Digital photographs of the irradiated mice are taken by illuminating the mouse skin with linearly polarized probe light of 650 nm. The specific pattern of the surface distribution of the degree of polarization enables the detection of initial skin fibrosis structures that were not visually apparent. Data processing of the raw spatial distributions of the degree of polarization based on Fourier filtering of the high-frequency noise improves subjective perception of the revealed structure in the images. In addition, Pearson correlation analysis provides information about skin structural size and directionality.

Algorithms↗