Overnight corneal swelling with silicone hydrogel contact lenses with high oxygen transmissibility.

PURPOSE: To compare central corneal swelling after 8 hours of sleep in eyes wearing 2 different silicone hydrogel lenses with high oxygen transmissibility. METHODS: Twenty neophyte subjects were randomly assigned to wear a comfilcon A lens (CooperVision Inc) in one eye and a lotrafilcon A lens (CIBA Vision) in the contralateral eye for an 8-hour overnight period. The study was repeated with another 20 neophyte subjects wearing comfilcon A in one eye only and no lens in the contralateral control eye. Central corneal thickness was measured with optical pachometry before lens insertion, immediately after lens removal on waking, at 20 and 40 minutes, 1 hour, 2 hours and 3 hours. RESULTS: There was no significant difference between the amount of overnight central corneal swelling induced by the 2 lenses (4.1% +/- 1.9% with comfilcon A vs. 4.0% +/- 1.7% with lotrafilcon A; P>0.05). The swelling of the comfilcon A lens-wearing eyes was significantly higher than that found in the non-lens-wearing contralateral eyes (4.5% +/- 2.1% vs. 3.0% +/- 1.7%; P<0.05). CONCLUSIONS: The same amount of overnight corneal swelling was induced by the 2 study lenses. The higher overnight swelling observed with the comfilcon A lenses compared to the non-lens-wearing eyes is similar to that reported in the literature for studies using lotrafilcon A lenses.

Adult↗

Novel pachometry calibration.

PURPOSE: The purpose of this study was to develop a simple method for cross-calibrating instruments that measure corneal thickness. METHODS: Fourteen rigid lenses of different thicknesses were manufactured using a material with refractive index of 1.376. Center thickness of the lenses (CT) was measured using a computerized optical pachometer (OP), two optical coherence tomographers (OCTs), and a confocal microscope (CM). Accuracy of measurements was compared between the four instruments. RESULTS: Before calibrating the machines, there was a significant effect of the measurement device (p < 0.05). The differences between instruments were eliminated (p > 0.05) after applying calibration equations for each device. In addition, after each instrument was calibrated with lenses of 1.376 refractive index, there was no significant difference (p > 0.05) between measured values of lens center thickness by OP, each OCT, CM, and the physical center thickness of the lenses. CONCLUSIONS: Using calibration lenses with the same refractive index as the cornea (1.376) allows rapid and simple calibration of the pachometers so that corneal thickness measurements from different devices can be used interchangeably.

Calibration↗

Contact lens-induced corneal swelling and surface changes measured with the Orbscan II corneal topographer.

PURPOSE: The purpose of this study was to measure central and topographical corneal swelling in response to contact lens wear and eye closure, to determine whether the swelling induced by soft and polymethyl methacrylate (PMMA) lenses is different, and to determine whether the anterior and/or posterior corneal shape alters with corneal swelling. METHODS: An Orbscan II corneal topographer was used to measure corneal swelling and the shape of the anterior and posterior corneal surfaces of 16 neophytes before and after wearing soft and PMMA contact lenses with near-zero oxygen transmissibility. The lens-wearing eye was patched for 3 h. RESULTS: The mean 15.1% +/- 3.8% (+/- SD) central corneal swelling with soft lenses was significantly >12.6% +/- 4.1% with PMMA lenses. Topographical corneal swelling was significantly greater with soft vs. PMMA lenses. However, the difference between central and peripheral corneal swelling was much greater with PMMA lenses. With both lenses, the cornea swelled significantly more in the center than the periphery. The anterior best-fit sphere radius remained unchanged in response to soft lenses (0.00 +/- 0.04 mm) and steepened slightly but significantly with PMMA lenses (-0.04 +/- 0.05 mm). The posterior best-fit sphere radius flattened significantly with both lenses (0.12 +/- 0.07 mm with soft and 0.14 +/- 0.08 mm with PMMA lenses). CONCLUSIONS: Corneal swelling (greater centrally than peripherally) flattens the posterior surface of the cornea and is independent of lens type. Although the anterior best-fit sphere radius steepened with PMMA, the magnitude is probably clinically unimportant. Both lens types produced greater central vs. peripheral corneal swelling. However, the soft lens induced significantly greater overall swelling than PMMA. Because their oxygen transmission was the same, these results suggest that there is lateral diffusion of oxygen from the peripheral area of the cornea (that is not covered by the lens) toward the center.

Adult↗