PubMed Health⌕ Search

Biomedical subjects

Amy E Herr

Publications and source records attributed to Amy E Herr.

6 recordsLinked to original sources

Integrated preconcentration SDS-PAGE of proteins in microchips using photopatterned cross-linked polyacrylamide gels.

The potential of integration of functions in microfluidic chips is demonstrated by implementing on-chip preconcentration of proteins prior to on-chip protein sizing by sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE). Two polymeric elements-a thin (approximately 50 microm) size exclusion membrane for preconcentration and a longer (approximately cm) porous monolith for protein sizing-were fabricated in situ using photopolymerization. Contiguous placement of the two polymeric elements in the channels of a microchip enabled simple and zero dead volume integration of the preconcentration with SDS-PAGE. The size exclusion membrane was polymerized in the injection channel using a shaped laser beam, and the sizing monolith was cast by photolithography using a mask and UV lamp. Proteins injected electrophoretically were trapped on the upstream side of the size exclusion membrane (MW cutoff approximately 10 kDa) and eluted off the membrane by reversing the electric field. Subsequently, the concentrated proteins were separated in a cross-linked polyacrylamide monolith that was patterned contiguous to the size exclusion membrane. The extent of protein preconcentration is easily tuned by varying the voltage during injection or by controlling the sample volume loaded. Electric fields applied across the nanoporous membrane resulted in a concentration polarization effect evidenced by decreasing current over time and irreproducible migration of proteins during sizing. To minimize the concentration polarization effect, sieving gels were polymerized only on the separation side of the membrane, and an alternate electrical current path was employed, bypassing the membrane, for most of the elution and separation steps. Electrophoretically sweeping a fixed sample volume against the membrane yields preconcentration factors that are independent of protein mobility. The volume sweeping method also avoids biased protein loading from concentration polarization and sample matrix variations. Mobilities of the concentrated proteins were log-linear with respect to molecular weight, demonstrating the suitability of this approach for protein sizing. Proteins were concentrated rapidly (<5 min) over 1000-fold followed by high-resolution separation in the sieving monolith. Proteins with concentrations as low as 50 fM were detectable with 30 min of preconcentration time. The integrated preconcentration-sizing approach facilitates analysis of low-abundant proteins that cannot be otherwise detected. Moreover, the integrated preconcentration-analysis approach employing in situ formation of photopatterned polymeric elements provides a generic, inexpensive, and versatile method to integrate functions at chip level and can be extended to lowering of detection limits for other applications such as DNA analysis and clinical diagnostics.

Acrylic Resins↗

Functional antibody immobilization on 3-dimensional polymeric surfaces generated by reactive ion etching.

Reactive ion etching (RIE) was used to pattern antibodies onto the surfaces of polymer substrates. A low pressure, inductively coupled oxygen plasma was used to anisotropically etch 25-30 mum deep features into poly(methyl methacrylate) (PMMA), Zeonex, and polycarbonate (PC). Scanning electron microscopy and contact angle measurements show that the resulting surfaces exhibit significant microroughness and enhanced hydrophilicity. Fourier transform infrared spectroscopy suggests that, in addition to enhanced surface area, chemical modifications may contribute to antibody immobilization. Polyclonal antibodies preferentially bind to the etched areas in RIE-patterned PMMA and Zeonex substrates but localize in unetched regions of RIE-patterned PC surfaces. Simple immunoassays were performed to demonstrate a potential application for RIE-modified polymer surfaces. Antibodies specific for the capture of fluorescently labeled cholera toxin, S. aureus enterotoxin B, and B. anthracis protective antigen were immobilized onto etched PMMA surfaces and shown to specifically capture their labeled antigen from solution. This work demonstrates a potentially useful fabrication methodology for constructing antibody microarrays on plastic substrates.

Antibodies↗

Antibody microarrays for native toxin detection.

We have developed antibody-based microarray techniques for the multiplexed detection of cholera toxin beta-subunit, diphtheria toxin, anthrax lethal factor and protective antigen, Staphylococcus aureus enterotoxin B, and tetanus toxin C fragment in spiked samples. Two detection schemes were investigated: (i) a direct assay in which fluorescently labeled toxins were captured directly by the antibody array and (ii) a competition assay that employed unlabeled toxins as reporters for the quantification of native toxin in solution. In the direct assay, fluorescence measured at each array element is correlated with labeled toxin concentration to yield baseline binding information (Langmuir isotherms and affinity constants). Extending from the direct assay, the competition assay yields information on the presence, identity, and concentration of toxins. A significant advantage of the competition assay over reported profiling assays is the minimal sample preparation required prior to analysis because the competition assay obviates the need to fluorescently label native proteins in the sample of interest. Sigmoidal calibration curves and detection limits were established for both assay formats. Although the sensitivity of the direct assay is superior to that of the competition assay, detection limits for unmodified toxins in the competition assay are comparable to values reported previously for sandwich-format immunoassays of antibodies arrayed on planar substrates. As a demonstration of the potential of the competition assay for unlabeled toxin detection, we conclude with a straightforward multiplexed assay for the differentiation and identification of both native S. aureus enterotoxin B and tetanus toxin C fragment in spiked dilute serum samples.

Antibodies, Monoclonal↗

On-chip native gel electrophoresis-based immunoassays for tetanus antibody and toxin.

By integrating photopolymerized cross-linked polyacrylamide gels within a microfluidic device, we have developed a microanalytical platform for performing electrophoresis-based immunoassays. The microfluidic immunoassays are performed by gel electrophoretic separation and quantitation of bound and unbound antibody or antigen. To retain biological activity of proteins and maintain intact immune complexes, nondenaturing polyacrylamide gel electrophoresis conditions were investigated. Both direct (noncompetitive) and competitive immunoassay formats are demonstrated in microchips. A direct immunoassay was developed for detection of tetanus antibodies in buffer as well as diluted serum samples. After an off-chip incubation step, the immunoassay was completed in less than 3 min and the sigmoidal dose-response curve spanned an antibody concentration range from 0.17 to 260 nM. The minimum detectable antibody concentration was 0.68 nM. A competitive immunoassay was also developed for tetanus toxin C-fragment by allowing unlabeled and fluorescently labeled tetanus toxin C-fragment compete to bind to a limited fixed concentration of tetanus antibody. The immunoassay technique described in this work shows promise as a component of an integrated microfluidic device amenable to automation and relevant to development of clinical diagnostic devices.

Antibodies↗

Photopolymerized cross-linked polyacrylamide gels for on-chip protein sizing.

A new method for on-chip sodium dodecyl sulfate polyacrylamide gel electrophoresis (SDS-PAGE) of proteins is reported. Miniaturization of SDS-PAGE has attracted significant attention because it offers rapid analysis times, excellent resolution, high throughput, and the potential for integration and automation, as compared to conventional counterparts. The presented on-chip SDS-PAGE technique employed photolithographically patterned, cross-linked gels fabricated in situ in <20 min. The effects of sieving gel composition on the migration properties of fluorescently labeled protein standards (ranging in molecular weight from 14.2 to 66 kDa) were quantified, as was the ability of the gels to function as a sieving matrix for biologically relevant species. Ferguson analysis was employed to calculate retardation coefficients and free solution mobilities. In conjunction with fluorescence imaging, the on-chip SDS-PAGE separation mechanism was evaluated in terms of separation performance indexes, as well as limiting behaviors (i.e., free solution mobility, exclusion characteristics). The photolithographically fabricated gels employed for on-chip SDS-PAGE allowed rapid (<30 s) separations of proteins in short separation lengths (4 mm) with efficiencies as high as 4.41 x 10(5) plates/m. The on-chip SDS-PAGE separations were approximately 100 times faster than conventional slab gel SDS-PAGE (60 min) and occurred in a fraction of the separation length required by slab gels. The migration behavior of protein standards correlated well with molecular weight and allowed molecular weight determination for interleukin-2, fibroblast growth factor, insulin-like growth factor, and tetanus toxin C-fragment.

Cross-Linking Reagents↗

On-chip coupling of isoelectric focusing and free solution electrophoresis for multidimensional separations.

We have developed an acrylic microfluidic device that sequentially couples liquid-phase isoelectric focusing (IEF) and free solution capillary electrophoresis (CE). Rapid separation (<1 min) and preconcentration (73x) of species were achieved in the initial IEF dimension. Using full-field fluorescence imaging, we observed nondispersive mobilization velocities on the order of 20 microm/s during characterization of the IEF step. This transport behavior allowed controlled electrokinetic mobilization of focused sample bands to a channel junction, where voltage switching was used to repeatedly inject effluent from the IEF dimension into an ampholyte-based CE separation. This second dimension was capable of analyzing all fluid volumes of interest from the IEF dimension, as IEF was 'parked' during each CE analysis and refocused prior to additional CE analyses. Investigation of each dimension of the integrated system showed time-dependent species displacement and band-broadening behavior consistent with IEF and CE, respectively. The peak capacity of the 2D system was approximately 1300. A comprehensive 2D analysis of a fluid volume spanning 15% of the total IEF channel length was completed in less than 5 min.

Algorithms↗