PubMed Health⌕ Search

Biomedical subjects

Amy L Lerner

Publications and source records attributed to Amy L Lerner.

7 recordsLinked to original sources

Stresses and strains in the medial meniscus of an ACL deficient knee under anterior loading: a finite element analysis with image-based experimental validation.

The menisci are believed to play a stabilizing role in the ACL-deficient knee, and are known to be at risk for degradation in the chronically unstable knee. Much of our understanding of this behavior is based on ex vivo experiments or clinical studies in which we must infer the function of the menisci from external measures of knee motion. More recently, studies using magnetic resonance (MR) imaging have provided more clear visualization of the motion and deformation of the menisci within the tibio-femoral articulation. In this study, we used such images to generate a finite element model of the medial compartment of an ACL-deficient knee to reproduce the meniscal position under anterior loads of 45, 76, and 107 N. Comparisons of the model predictions to boundaries digitized from images acquired in the loaded states demonstrated general agreement, with errors localized to the anterior and posterior regions of the meniscus, areas in which large shear stresses were present. Our model results suggest that further attention is needed to characterize material properties of the peripheral and horn attachments. Although overall translation of the meniscus was predicted well, the changes in curvature and distortion of the meniscus in the posterior region were not captured by the model, suggesting the need for refinement of meniscal tissue properties.

Aged↗

Sensitivities of medial meniscal motion and deformation to material properties of articular cartilage, meniscus and meniscal attachments using design of experiments methods.

This study investigated the role of the material properties assumed for articular cartilage, meniscus and meniscal attachments on the fit of a finite element model (FEM) to experimental data for meniscal motion and deformation due to an anterior tibial loading of 45 N in the anterior cruciate ligament-deficient knee. Taguchi style L18 orthogonal arrays were used to identify the most significant factors for further examination. A central composite design was then employed to develop a mathematical model for predicting the fit of the FEM to the experimental data as a function of the material properties and to identify the material property selections that optimize the fit. The cartilage was modeled as isotropic elastic material, the meniscus was modeled as transversely isotropic elastic material, and meniscal horn and the peripheral attachments were modeled as noncompressive and nonlinear in tension spring elements. The ability of the FEM to reproduce the experimentally measured meniscal motion and deformation was most strongly dependent on the initial strain of the meniscal horn attachments (epsilon(1H)), the linear modulus of the meniscal peripheral attachments (E(P)) and the ratio of meniscal moduli in the circumferential and transverse directions (E(theta)E(R)). Our study also successfully identified values for these critical material properties (epsilon(1H) = -5%, E(P) = 5.6 MPa, E(theta)E(R) = 20) to minimize the error in the FEM analysis of experimental results. This study illustrates the most important material properties for future experimental studies, and suggests that modeling work of meniscus, while retaining transverse isotropy, should also focus on the potential influence of nonlinear properties and inhomogeneity.

Aged↗

Rabbit knee joint biomechanics: motion analysis and modeling of forces during hopping.

Although the rabbit hindlimb has been commonly used as an experimental animal model for studies of osteoarthritis, bone growth and fracture healing, the in vivo biomechanics of the rabbit knee joint have not been quantified. The purpose of this study was to investigate the kinematic and kinetic patterns during hopping of the adult rabbit, and to develop a model to estimate the joint contact force distribution between the tibial plateaus. Force platform data and three-dimensional motion analysis using infrared markers mounted on intracortical bone pins were combined to calculate the knee and ankle joint intersegmental forces and moments. A statically determinate model was developed to predict muscle, ligament and tibiofemoral joint contact forces during the stance phase of hopping. Variations in hindlimb kinematics permitted the identification of two landing patterns, that could be distinguished by variations in the magnitude of the external knee abduction moment. During hopping, the prevalence of an external abduction moment led to the prediction of higher joint contact forces passing through the lateral compartment as compared to the medial compartment of the knee joint. These results represent critical data on the in vivo biomechanics of the rabbit knee joint, which allow for comparisons to both other experimental animal models and the human knee, and may provide further insight into the relationships between mechanical loading, osteoarthritis, bone growth, and fracture healing.

Animals↗

Fibronectin matrix polymerization increases tensile strength of model tissue.

The composition and organization of the extracellular matrix (ECM) contribute to the mechanical properties of tissues. The polymerization of fibronectin into the ECM increases actin organization and regulates the composition of the ECM. In this study, we examined the ability of cell-dependent fibronectin matrix polymerization to affect the tensile properties of an established tissue model. Our data indicate that fibronectin polymerization increases the ultimate strength and toughness, but not the stiffness, of collagen biogels. A fragment of fibronectin that stimulates mechanical tension generation by cells, but is not incorporated into ECM fibrils, did not increase the tensile properties, suggesting that changes in actin organization in the absence of fibronectin fibril formation are not sufficient to increase tensile strength. The actin cytoskeleton was needed to initiate the fibronectin-induced increases in the mechanical properties. However, once fibronectin-treated collagen biogels were fully contracted, the actin cytoskeleton no longer contributed to the tensile strength. These data indicate that fibronectin polymerization plays a significant role in determining the mechanical strength of collagen biogels and suggest a novel mechanism by which fibronectin can be used to enhance the mechanical performance of artificial tissue constructs.

Actins↗

The use of sequential MR image sets for determining tibiofemoral motion: reliability of coordinate systems and accuracy of motion tracking algorithm.

The use of magnetic resonance imaging has been proposed by many investigators for establishment of joint reference systems and kinematic tracking of musculoskeletal joints. In this study, the intraobserver and interobserver reliability of a strategy to establish anatomic reference systems using manually selected fiducial points were quantified for seven sets of MR images of the human knee joint. The standard error of the measurement of the intraobserver and interobserver errors were less than 2.6 degrees, and 1.2 mm for relative tibiofemoral orientation and displacement, respectively. An automated motion tracking algorithm was also validated with a controlled motion experiment in a cadaveric knee joint. The controlled displacements and rotations prescribed in our motion tracking validation were highly correlated to those predicted (Pearson's correlation = 0.99, RMS errors = 0.39 mm, 0.38 degree). Finally, the system for anatomic reference system definition and motion tracking was demonstrated with a set of MR images of in vivo passive flexion in the human knee.

Adult↗

Effects of childhood obesity on three-dimensional knee joint biomechanics during walking.

Despite the increasing percentages of children who are overweight, few studies have investigated their gait patterns. The purpose of this study was to quantify the three-dimensional knee joint kinematics and kinetics during walking in children of varying body mass and to identify effects associated with obesity. Three-dimensional kinematics and kinetics were collected from children of normal weight and overweight during normal gait using surface-mounted infrared emitting diodes and a force plate. The overweight group walked with a significantly lower peak knee flexion angle during early stance, and no significant differences in peak internal knee extension moments were found between groups. However, the overweight group showed a significantly higher peak internal knee abduction moment during early stance. These data suggest that although overweight children may develop a gait adaptation to maintain a similar knee extensor load, they may not be able to compensate for alterations in the frontal plane, which may lead to increased medial compartment joint loads. Therefore, assuming that the development of varus angular deformities of the knee joint and, in the longer term, medial compartment osteoarthritis are influenced by cumulative stress, this study supports the understanding that childhood obesity may impart a greater risk for the development of these diseases.

Biomechanical Phenomena↗