PubMed Health⌕ Search

Biomedical subjects

Ana Paula S Paim

Publications and source records attributed to Ana Paula S Paim.

2 recordsLinked to original sources

Automatic potentiometric flow titration procedure for ascorbic acid determination in pharmaceutical formulations.

A flow procedure for the determination of ascorbic acid in pharmaceutical formulations exploiting potentiometric titration is described. The method is based on the reduction of IO3- by ascorbic acid and the detection was carried out employing a flow-through ion selective electrode for iodide. The flow network controlled by a microcomputer was designed to implement multicommutation for ease of operation and robustness. The titration system allowed the determination of ascorbic acid in pharmaceutical formulations with concentrations ranging from 7.5 to 15.0 mmol l(-1). No significant differences at the 95% confidence level were observed in comparison with results obtained by a manual procedure. Merit figures of results such as a relative standard deviation of 1.0% (n=6) and a reagent consumption of 21.4 mg IO3- per determination were obtained.

Ascorbic Acid↗

Automatic flow system titration based on multicommutation for spectrophotometric determination of total acidity in silage extracts.

A multicommutated flow titration procedure is proposed for the spectrophotometric determination of total acidity in silage extracts. The flow network comprises a set of 3-way solenoid valves, computer-controlled to provide facilities to handle the titrand, titrant, and carrier solutions by using a single pumping channel. The procedure is based on the volumetric fraction variation approach that maintains the same volume of titrand solution and varies the titrant solution step by step, to provide determination without the use of an analytical curve. The procedure is implemented by using phenolphthalein as an external indicator; the proposed algorithm was able to titrate silage extracts presenting different color intensities. Sample solutions with concentrations ranging from 10(-3) to 10(-1) mol/L total acidity could be analyzed by using 10(-2) mol/L sodium hydroxide as the titrant solution. Other advantages include a relative standard deviation of <1.0% (n = 4) for a typical silage extract solution containing 26 mmol/L total acidity; an analytical throughput of 16 determinations per hour was also achieved. Accuracy was assessed by processing a set of silage extract solutions and comparing the results with those obtained by using the conventional potentiometric titration procedure. No significant difference at the 95% confidence level was observed.

Hydrogen-Ion Concentration↗