PubMed Health⌕ Search

Biomedical subjects

Anders Holm

Publications and source records attributed to Anders Holm.

15 recordsLinked to original sources

Adapted preparation technique for screw-type implants: explorative in vitro pilot study in a porcine bone model.

OBJECTIVE: The aim of this study was to quantify the effect of adapted preparation on the insertion torque of self-tapping implants in cancellous bone. In adapted preparation, bone condensation - and thus, insertion torque - is controlled by changing the diameter of the drilling. MATERIAL AND METHODS: After preparation of cancellous porcine vertebral bone with drills of 2.85, 3, 3.15 or 3.35 mm final diameters, Brånemark sytem Mk III implants (3.75 x 11.5 mm) were inserted in 141 sites. During implantation, the insertion torque was recorded. Prior to implant insertion, bone mineralization (bone mineral density (BMD)) was measured with dental quantative computed tomography. The BMD values measured at the implant position were correlated with insertion torque for varying bone condensation. RESULTS: Based on the average torque recorded during implant insertion into the pre-drilled canals with a diameter of 3 mm, torque increased by approximately 17% on reducing the diameter of the drill by 5% (to 2.85 mm). On increasing the diameter of the osteotomy to 3.15 mm (5%) or 3.35 mm (12%), torque values decreased by approximately 21% and 50%, respectively. CONCLUSION: The results demonstrate a correlation between primary stability (average insertion torque) and the diameter of the implant bed on using a screw-shaped implant. Thus, using an individualized bone mineralization-dependent drilling technique, optimized torque values could be achieved in all tested bone qualities with BMDs ranging from 330 to 500 mg/cm(3). The results indicate that using a bone-dependent drilling technique, higher torque values can also be achieved in poor bone using an individualized drilling resulting in higher bone condensation. As immediate function is dependent on primary stability (high insertion torque), this indicates that primary stability can be increased using a modified drilling technique in lesser mineralized bone.

Animals↗

Limitations of porous graphitic carbon as stationary phase material in the determination of catecholamines.

A fast and sensitive capillary liquid chromatography (cLC) column-switching method with electrospray ionization time-of-flight mass spectrometry (ESI-TOF-MS) detection for the simultaneous determination of dopamine (D), epinephrine (E), norepinephrine (NE) and serotonin (SE) was pursued. A sample volume of 100 microl was loaded with a mobile phase containing 0.1% pentafluoropropionic acid (PFPA) as ion-pairing agent on a 25 mm x 0.32 mm (i.d.) 5 microm Hypercarb column. A water-acetonitrile (AcN) gradient with 0.1% acetic acid (AcOH) backflushed the compounds onto a 34 mm x 0.32 mm (i.d.) 5 microm Hypercarb analytical column. However, during a series of analyses, oxidation of the catecholamines (CAs) was observed. This was suspected to be due to the loading mobile phase composition and precluded the usefulness of this method even though the achievable detection limit was in the range of 0.75-3.0 ng/ml. The combination of the porous graphitic carbon (PGC) material and the fluorinated strong acids which were required to get enough retention for preconcentration of large volumes cannot be used for easily oxidized compounds as the CAs.

Catecholamines↗

Specific modification of peptide-bound citrulline residues.

Immune reactions to citrulline-containing proteins appear to be central in the immunopathogenesis of rheumatoid arthritis. Citrulline residues are introduced into proteins by deimination of arginine residues, likely by an enzymatic process. There is a need to characterize which proteins in the inflamed joints of rheumatoid patients contain citrulline in situ. The characterization of deiminated proteins will be greatly facilitated by specific modification of peptide-bound citrulline residues that will enable specific enrichment and detection of citrulline-containing peptides. This study presents the details of such a modification method. The chemistry behind the reaction of the ureido group of citrulline with 2,3-butanedione in the presence of antipyrine is unraveled. Parameters for optimization of the reaction with respect to specificity and completeness, including the testing of different acids, reactant concentrations, and reaction time, are presented. This modification reaction is specific for citrulline residues. The modified product shows a characteristic mass shift of +238Da, as demonstrated by mass spectrometry. The product absorbs UV-Vis radiation at 464nm, and it is demonstrated that this can be used to selectively monitor citrulline-containing peptides during the separation of protein digests. Finally, the structure of the product of modified citrulline is solved by nuclear magnetic resonance spectroscopy using N-butylurea as a model substance. The results presented should facilitate the development of tags that can be used for the enrichment and subsequent detection of citrulline-containing protein fragments by mass spectrometry.

Antipyrine↗

Fractionation and separation of human salivary proteins by pH-gradient ion exchange and reversed phase chromatography coupled to mass spectrometry.

In the present work, a 2-D capillary liquid chromatography method for fractionation and separation of human salivary proteins is demonstrated. Fractionation of proteins according to their pI values was performed in the 1-D employing a strong anion exchange (SAX) column subjected to a wide-range descending pH gradient. Polystyrene-divinylbenzene (PS-DVB) RP columns were used for focusing and subsequent separation of the proteins in the 2-D. The SAX column was presaturated with a high pH buffer (A) consisting of 10 mM amine buffering species, pH 9.0, and elution was performed with a low pH elution buffer (B) having the same buffer composition and concentration as buffer A, but pH 3.5. Isoelectric point fractions eluting from the 1-D column were trapped on PS-DVB trap columns prior to back-flushed elution onto the PS-DVB analytical column for separation of the proteins. The 1-D fraction eluting at pH 9.0-8.7 was chosen for further analysis. After separation on the RP analytical column, nine RP protein fractions were collected and tryptic digested for subsequent analyses by MALDI TOF MS and column switching capillary LC coupled to ESI TOF MS and ESI QTOF MS. Eight proteins and two peptides were identified in the pH 9.0-8.7 fraction using peptide mass fingerprinting and uninterpreted MS/MS data.

Chromatography, High Pressure Liquid↗

Case management interviews and the return to work of disabled employees.

This study measures the effect of case management interview (CMI) on 1,000 long-term sick-listed employees' probability of returning to work. In contrast to previous studies, we use instrumental variables to correct for selection effects in CMI. Using a competing hazard rate model, we find that CMI increases the probability of returning to work for the pre-sick leave employer, but has no effect on the probability of resuming work for a new employer. We argue that CMI either motivates the sick-listed employees to resume work or adjusts for asymmetric information between the employee and the pre-sick leave employer.

Adult↗

Combined solid-phase extraction and 2D LC-MS for characterization of the neuropeptides in rat-brain tissue.

A comprehensive two-dimensional capillary liquid chromatographic (2D LC) method has been established for determination of neuropeptides in rat brain tissue. Rats were exposed to different levels of stress before sacrificing and the aim of this study was to design a powerful separation and detection technique capable of characterizing differences between cerebral neuropeptide expression as a function of stress level. Rat brain samples were homogenized and subjected to clean-up by solid-phase extraction (SPE) on both a reversed-phase (C(18)) and a weak cation-exchange (CBA) cartridge. The samples were divided in two fractions (A and B) depending on retention on the CBA column. Subsequently, 50 microL of the sample were injected on to a strong cation exchanger (SCX) at a mobile phase pH of 3, which enabled preconcentration of positively charged compounds. The trapped compounds were eluted using step gradients of ammonium formate in water-ACN (90:10, v/v). Before enrichment in the second dimension, the eluate from the first dimension was diluted with water containing 0.1% TFA. The compounds eluting from the first dimension were trapped in the second dimension using a dual precolumn system consisting of two short capillary columns packed with Kromasil C(18), 10 microm particles. Subsequently, the trapped compounds were backflushed on to a 10 cm long, 320 microm I.D. analytical column packed with Kromasil C(18) 3.5 microm particles, on which they were efficiently separated. Detection was performed using an ion-trap mass spectrometer (ITMS) in both the MS and the MS-MS mode. Comparison of base-peak chromatograms (BPC) from MS analysis of stressed and non-stressed rats clearly revealed several differences in neuropeptide expression. The MS-MS data obtained combined with Mascot software were employed for peptide identification.

Animals↗

Determination of bradykinin and arg-bradykinin in rat muscle tissue by microdialysis and capillary column-switching liquid chromatography with mass spectrometric detection.

Quantification of bradykinin peptides in limited amounts of rat muscle tissue dialysate has been performed using a packed capillary LC-ESI-TOF-MS method. The micro dialysate samples (450 microL) with added internal standard were loaded onto a 1 mm x 5 mm loading column packed with 5 microm Kromasil C18 particles by a carrier solution of 0.1% formic acid in ACN/water (5:95, v/v) at a flow rate of 250 microL/min for online preconcentration of the analytes. Back-flushed elution onto a 150 mm x 0.5 mm Zorbax C18 column packed with 5 microm particles was conducted using a linear solvent ACN/H2O gradient containing 0.1% formic acid. (Tyr8)-bradykinin was used as an internal standard and was added to the dialysis sample prior to injection. Baseline separation of bradykinin, arg-bradykinin and (tyr8)-bradykinin was achieved within 10 min. Positive ESI was performed in the m/z range of 200-1300. The method was validated in the range 0.2-1.0 ng/mL dialysate, yielding correlation coefficients of 0.995 and 0.990 for bradykinin and arg-bradykinin, respectively. The within-assay and between-assay precisions were between 4.3-9.6% and 6.2-10.6%, respectively. Both arg-bradykinin and bradykinin were detected in dialysate from rat muscle tissue, at concentrations of 0.1 and 0.4 ng/mL for bradykinin and arg-bradykinin, respectively, confirming the presence of arg-bradykinin in rat muscles.

Animals↗

Forest soil respiration rate and delta13C is regulated by recent above ground weather conditions.

Soil respiration, a key component of the global carbon cycle, is a major source of uncertainty when estimating terrestrial carbon budgets at ecosystem and higher levels. Rates of soil and root respiration are assumed to be dependent on soil temperature and soil moisture yet these factors often barely explain half the seasonal variation in soil respiration. We here found that soil moisture (range 16.5-27.6% of dry weight) and soil temperature (range 8-17.5 degrees C) together explained 55% of the variance (cross-validated explained variance; Q2) in soil respiration rate (range 1.0-3.4 micromol C m(-2) s(-1)) in a Norway spruce (Picea abies) forest. We hypothesised that this was due to that the two components of soil respiration, root respiration and decomposition, are governed by different factors. We therefore applied PLS (partial least squares regression) multivariate modelling in which we, together with below ground temperature and soil moisture, used the recent above ground air temperature and air humidity (vapour pressure deficit, VPD) conditions as x-variables. We found that air temperature and VPD data collected 1-4 days before respiration measurements explained 86% of the seasonal variation in the rate of soil respiration. The addition of soil moisture and soil temperature to the PLS-models increased the Q2 to 93%. delta13C analysis of soil respiration supported the hypotheses that there was a fast flux of photosynthates to root respiration and a dependence on recent above ground weather conditions. Taken together, our results suggest that shoot activities the preceding 1-6 days influence, to a large degree, the rate of root and soil respiration. We propose this above ground influence on soil respiration to be proportionally largest in the middle of the growing season and in situations when there is large day-to-day shifts in the above ground weather conditions. During such conditions soil temperature may not exert the major control on root respiration.

Betula↗

Temperature-programmed packed capillary liquid chromatography coupled to evaporative light-scattering detection and electrospray ionization time-of-flight mass spectrometry for characterization of high-molecular-mass hindered amine light stabilizers.

High-molecular weight-hindered amine light stabilizers (HMW-HALSs) are of utmost importance in modern polyolefin stabilization technology and in-depth knowledge about their chemical composition, particularly the oligomers, is essential for development of new and more efficient stabilizers. In the present study, the applicability of temperature-programmed packed capillary LC coupled to miniaturized ELSD and positive mode ESI-TOF-MS for analysis of HMW-HALSs is demonstrated through extensive characterization of two state-of-the-art stabilizers, i.e., HALS-1 and HALS-2. Both stabilizers were individually separated on a 320 microm i.d. x 35 cm long Hypersil 3 microm ODS-100 column using a temperature program from 30 to 120 degrees C and a quaternary mixture of ethylacetate, acetonitrile, triethylamine (TEA) and acetic acid (45.0:44.9:10.0:0.1 (v/v/v/v)) as the mobile phase. The effect of using various amounts of ethylacetate, acetonitrile and triethylamine in the mobile phase on the chromatographic separation is demonstrated. Furthermore, the LC-ESI-TOF-MS analyses revealed that HALS-1 (oligomeric) was highly complex and consisted of at least five different mass series, while HALS-2, which was assumed to be monomeric, contained two different mass series. Chemical structures for nearly all species of both stabilizers are proposed.

Amines↗

Sensitive biomonitoring of phthalate metabolites in human urine using packed capillary column switching liquid chromatography coupled to electrospray ionization ion-trap mass spectrometry.

A rapid and sensitive method for the determination of the phthalate monoesters monoethyl phthalate (MEP), monobutyl phthalate (MBP), monobenzyl phthalate (MBzP) and monoethylhexyl phthalate (MEHP), in human urine, using packed capillary column liquid chromatography coupled to electrospray quadrupole-ion trap mass spectrometry (ESI-QITMS(n)) has been developed. Sample volumes of 200 microL of deconjugated and diluted urine were loaded onto a precolumn of 30 mmx0.32 mm I.D. packed with Hypercarb 5 microm particles, using a sample carrier consisting of acetonitrile/water (15/85, v/v, adjusted to pH 2 using HCl) with a flow rate of 20 microL/min. Backflushed elution onto a 100 mmx0.32 mm I.D. analytical column packed with 5 microm Hypercarb particles was conducted using a tetrahydrofuran/water gradient where both solvents contained 10 mM ammonium acetate, at a flow rate of 4 microL/min. Determination of the monophthalates was achieved within 8 min. Ionization was performed in the negative mode and the analytes were observed as [M-H](-) at m/ z=193.1, 221.1, 255.1 and 277.0 for MEP, MBP, MBzP and MEHP, respectively. Quantification was performed in the multiple reaction monitoring (MRM) mode monitoring the fragments at m/ z=121.1, 177.0, 183.0 and 233.0 for MEP, MBP, MBzP and MEHP, respectively. The method was validated over the concentration range 2.5-125 ng/mL in pretreated urine samples, corresponding to 25-1250 ng/mL untreated urine, yielding correlation coefficients in the range 0.996-0.999. The within-assay ( n=6) and between-assay ( n=6) repeatabilities were in the range 4.0-18% and 4.8-15% RSD, respectively. The mass limits of detection were in the range 32-70 pg, corresponding to concentration limits of detection of 1.6-3.5 ng/mL of untreated urine.

Chromatography, Liquid↗

Determination of perfluorooctane sulfonate and perfluorooctanoic acid in human plasma by large volume injection capillary column switching liquid chromatography coupled to electrospray ionization mass spectrometry.

Rapid, selective, and sensitive methodology for the quantification of perfluorooctanoic acid (PFOA) and perfluorooctane sulfonate (PFOS) in human plasma using packed capillary liquid chromatography coupled to electrospray ionization ion-trap mass spectrometry has been developed. Plasma proteins were precipitated using acetonitrile and the resulting supernatant was diluted 1+1 with water containing 10 mM ammonium acetate (NH4Ac) prior to injection. Sample volumes of 250 microL were loaded onto a 30 mm x 0.32 mm ID 10 microm Kromasil C18 precolumn by a carrier solution consisting of 10 mM NH4Ac in ACN/H2O (5/95, v/v) at a flow rate of 100 microL/min, providing on-line analyte enrichment and sample clean-up. Backflushed elution onto a 100 mm x 0.32 mm ID 3.5 microm Kromasil C18 analytical column was conducted using an ACN/H2O solvent gradient containing 10 mM NH4Ac. In order to improve the robustness and performance of the method, perfluoroheptanoic acid (PFHA) was used as internal standard. Separation and detection of PFOA, PFHA, and PFOS were achieved within 10 minutes. Ionization was performed in the negative mode in the m/z range 250-550. The method was validated over the concentration range 1-200 ng/mL for PFOA and over the range 5-200 ng/mL untreated plasma for PFOS, yielding correlation coefficients of 0.997 (PFOA) and 0.996 (PFOS), respectively. The within-assay (n = 6) and between-assay (n = 6) precisions were in the range 2.1-9.2 and 5.6-12%, respectively. The concentration limits of detection (cLOD) of PFOA was 0.5 ng/mL while the cLOD of PFOS was estimated to be 0.2 ng/mL in untreated plasma.

Alkanesulfonic Acids↗

Trace determination of peptides in water samples using packed capillary liquid chromatography with UV and MS detection and characterization of peptide oxidation products by MS.

A capillary liquid chromatographic column switching method has been developed for fast and sensitive determination of peptides in water samples. Sample volumes of 1 mL were loaded onto a (320 microm I.D. x30 mm) 10 microm Kromasil C(18) pre-column, providing on-line analyte enrichment, prior to back-flushed elution onto a (320 microm I.D. x150 mm) 3.5 microm Kromasil C(18) analytical column. Loading flow rates of 250 microL/min and a mobile phase composition of acetonitrile/water/trifluoroacetic acid (22/77.9/0.1, v/v) provided a total analysis time of less than 25 minutes for the test peptides angiotensin II, bombesin, bradykinin, corazonin, neurotensin and substance P, using temperature programmed elution. In addition, solvent gradient elution and combined solvent gradient elution and temperature programming were explored. Using on-capillary UV detection at 210 nm resulted in a concentration limit of detection (cLOD) of about 1 ng/mL. The method was validated over the concentration range 1-100 ng/mL, yielding a coefficient of correlation of 0.997 or better. The within-assay ( n=6) and between-assay ( n=6) precisions of peak areas were on average 6% RSD and 5% RSD, respectively. When the method was applied to spiked chlorinated tap water samples, it was found that peptides containing methionine, tryptophan and cystine were oxidized. Identification of the oxidation products of the peptides in hypochlorite-treated water was done with positive electrospray ionization time-of-flight mass spectrometric detection.

Capillary Action↗

Fast and sensitive determination of urinary 1-hydroxypyrene by packed capillary column switching liquid chromatography coupled to micro-electrospray time-of-flight mass spectrometry.

The present work reports capillary liquid chromatographic column switching methodology tailored for fast, sensitive and selective determination of 1-hydroxypyrene (1-OHP) in human urine using micro-electrospray ionization time-of-flight mass spectrometric detection. Samples (100 microl) of deconjugated, water diluted and filtered urine samples were loaded onto a 150 microm I.D.x 30 mm 10 microm Kromasil C(18) pre-column, providing on-line sample clean-up and analyte enrichment, prior to back flushed elution onto a 150 microm I.D.x 100 mm 3.5 microm Kromasil C(18) analytical column. Loading flow rates up to 100 microl/min in addition to the use of isocratic elution by a mobile phase composition of acetonitrile/water (70/30, v/v) containing 5 mM ammonium acetate provided elution of 1-OHP within 5.5 min and a total analysis time of less than 15 min with manual operation. Ionization was performed in the negative mode and 1-OHP was observed as [M-H](-) at m/z 217.08. The method was validated over the concentration range 0.2-40 ng/ml 1-OHP in pre-treated urine, yielding a coefficient of correlation of 0.997. The within-assay (n=6) and between-assay (n=6) precisions were in the range 6.4-7.3 and 7.0-8.1%, respectively, and the recoveries were in the range 96.2-97.5 within the investigated concentration range. The method mass limit of detection was 2 pg, corresponding to a 1-OHP concentration limit of detection of 20 pg/ml (0.09 nmol/l) diluted urine or 0.3 ng/ml (1.35 nmol/l) urine.

Pyrenes↗

Correlation of insertion torques with bone mineral density from dental quantitative CT in the mandible.

OBJECTIVE: The aim of this study was to establish a correlation between bone mineral density measured preoperatively with dental computed tomography (CT), and insertion torque of screw-shaped dental implants. MATERIAL AND METHODS: In eight human mandibles obtained postmortem, bone mineral density (BMD) was measured with dental quantitative CT (DQCT) and correlated with insertion torque values at 45 implant sites during insertion of screw-shaped dental implants (Brånemark System MKIII, Nobel Biocare, AB, Göteborg, Sweden). RESULTS: A significant correlation (r=0.86, P<0.001) between BMD and torque values was observed, indicating that local BMD at a specific implant position is related to the supportive capacity of the jawbone. BMD exhibited no correlation with bone height or position. CONCLUSION: The noninvasive assessment of BMD using a DQCT scan employing a low-dose protocol may be used to estimate expected primary stability depending on BMD, implant type and preparation procedure. These data may therefore help the surgeon to select the optimum implant position, implant type and operation technique.

Absorptiometry, Photon↗

Temperature-promoted large-volume solute enrichment in column-switching miniaturized liquid chromatography: determination of an antioxidant.

A two-valve sub-ambient temperature-promoted reversed-phase packed-capillary liquid-chromatography column-switching system has been tailored for sensitive determination of hydrophobic compounds. Such compounds are not easily dissolved in solvent mixtures of non-eluting properties that traditionally are used for solute enrichment in reversed-phase liquid chromatography. Enrichment-column solute focusing of large sample volumes was promoted by use of sub-ambient temperatures only, allowing the use of sample solvents that were stronger or equal to the mobile phase solvent strength. Subsequent column switching and enrichment-column temperature increment provided efficient low-dispersion back-flushed enrichment-column solute desorption onto the analytical column, where the solute was subjected to temperature-programmed gradient action. The antioxidant, Irganox 1076 (octadecyl 3-(3,5-di-tert-butyl-4-hydroxyphenyl)propionate) extracted from low density polyethylene with 100% acetonitrile served as a hydrophobic model compound. The mobile phase consisted of acetonitrile containing 10 mM triethylamine and formic acid, and the 0.25 mm id enrichment-column and analytical column in lengths of 27 and 250 mm, respectively, were packed with 3.5 microm Kromasil C18 particles. Sample volumes of up to 500 microL were successfully focused on the enrichment column at 5 degrees C using loading flow rates of up to 40 microL min(-1) prior to temperature programming to 90 degrees C. The concentration limit of detection of Irganox 1076 was 6 ng mL(-1) when using an injection volume of 500 microL. The within-assay precision was in the range 3.5-6.8% (n = 6) while the between-day precision was 7.5% (n = 3) relative standard deviation. The method was linear within the investigated mass range 3-100 ng (R2 = 0.9993).

Antioxidants↗