PubMed Health⌕ Search

Biomedical subjects

Anders Mølster

Publications and source records attributed to Anders Mølster.

4 recordsLinked to original sources

A sixteen-year follow-up of three operative techniques for the treatment of acute ruptures of the anterior cruciate ligament.

BACKGROUND: This study compares three surgical procedures that we used in the past to treat ruptures of the anterior cruciate ligament: acute primary repair, acute repair augmented with a synthetic ligament-augmentation device, and acute repair augmented with autologous bone-patellar tendon-bone graft. METHODS: This is the third report on a group of patients who were randomized to the three different procedures between 1986 and 1988. There were fifty patients in each group. The patients were evaluated prospectively at one, two, five, and sixteen years with use of the Tegner activity score and the Lysholm functional score. Stability of the knee was assessed with clinical examination and with use of the KT-1000 arthrometer. RESULTS: One hundred and twenty-nine (88%) of the 147 patients who were available for follow-up completed the study. Eleven patients (24%) who had a primary repair, four patients (10%) who had repair with a ligament augmentation device, and one patient (2%) who had augmentation with autologous bone-patellar tendon-bone graft underwent anterior cruciate ligament revisions between the primary operation and the sixteen-year follow-up examination. The rate of revision was ten times higher in the group that had primary repair than in the group that had repair with bone-patellar tendon-bone graft (p = 0.003). In the remaining patients, those who had repair with a bone-patellar tendon-bone graft had significantly more stable knees than those who had repair with a ligament augmentation device, as measured by the Lachman test (p = 0.026). Nine (11%) of the eighty-five patients for whom data were available had osteoarthritis in the primarily reconstructed knee, and three patients (3.5%) had osteoarthritis in the contralateral knee at sixteen years (p = 0.001); no difference was noted among the three groups. The mean Lysholm score at sixteen years was 88 points for the knees that had primary repair, 85 points for those that had repair with the ligament augmentation device, and 90 points for those managed with a bone-patellar tendon-bone graft (p = 0.286). CONCLUSIONS: At long-term (sixteen-year) follow-up, the rate of revision anterior cruciate ligament surgery is much higher following primary repair than after primary repair augmented by a bone-patellar tendon-bone graft. It can be expected that approximately 10% of patients undergoing anterior cruciate ligament reconstruction acutely will have osteoarthritis develop in the reconstructed knee. We no longer perform any of these surgical techniques as open procedures.

Adolescent↗

External fixation versus locked intramedullary nailing in tibial shaft fractures: a prospective, randomised study of 78 patients.

INTRODUCTION: We performed a prospective, randomised study to compare the Ex-fi-re external fixator (EF) with locked intramedullary (IM) nailing in tibial fractures. Only fractures without soft-tissue problems of importance were included. MATERIALS AND METHODS: Ex-fi-re is a unilateral, dynamic axial fixator with fracture reduction capabilities. The Grosse-Kempf nail was used for nailing. A total of 78 patients with 79 fractures were entered in the study (41 Ex-fi-re, 38 IM nails). RESULTS: Time to radiographic union and full weight-bearing did not differ significantly, but unprotected weight-bearing was achieved earlier in the IM group (12 vs 20 weeks; p<0.001). There were more reoperations due to secondary dislocation in the EF group. There were no differences in final angulation or shortening. After 6 months and 1 year there were no differences in knee motion, ankle motion, fracture site pain or ankle pain. Some 64% of the nailed patients complained of anterior knee pain after 1 year. CONCLUSION: The results were comparable in most respects. Unprotected weight-bearing was achieved earlier after IM nailing. Anterior knee pain was frequent after nailing.

Adolescent↗

[Removal of osteosynthetic implants].

BACKGROUND: Removals of fracture implants constitute a considerable share of orthopaedic operations and take up significant hospital resources. In the Norwegian basic fracture course, guidelines are given on indications for removal as well as minimum function time for implants. Indications for implant removal are, however, relative, and we wanted to study actual practice in this field in Norway. MATERIAL AND METHODS: An inquiry was made to Norwegian hospitals in spring 2000 concerning their current practice for implant removal. RESULTS: Most hospitals follow the suggestions given but there is still great variation, especially in age limits for routine removal of all implants, which range from 15 to 70 years. INTERPRETATION: Implant removal is desirable after fracture healing but it requires a surgical procedure with a certain morbidity and incidence of complications. Lack of strict criteria for removal may explain varying practice. We conclude that there should be a uniform practice for implant removal in Norwegian hospitals. More research is warranted on the possible systemic and local long-term effects of implants remaining in situ in order to give more evidence-based indications for implant removal.

Adolescent↗

Slippage between screwdriver and bone screw.

Cortical 3.5-mm stainless steel screws with hexagonal heads and corresponding screwdrivers from two manufacturers were investigated. Measurement of dimensions and torsional testing were done to study slippage between the screw and the driver bit. There were only small differences in dimensions between the manufacturers. Ultimate torque values obtained were at the level of 2.7 N-m where reaming of the screw socket took place. Additional rotation resulted in approximately (1/2) of the maximum torque. Subsequent torque testing in the opposite direction, corresponding to removal of the screw, revealed that the torque values were equally low in that direction. Additional insertion and removal of bone screws with hexagonal sockets are hampered after only one episode of slippage. It is justified to consider new shapes of drive bits and corresponding screw head sockets, such as a fluted multiedge configuration.

Bone Screws↗