Comparison of clinical and physical measures of image quality in chest and pelvis computed radiography at different tube voltages.

The aim of this work was to study the dependence of image quality in digital chest and pelvis radiography on tube voltage, and to explore correlations between clinical and physical measures of image quality. The effect on image quality of tube voltage in these two examinations was assessed using two methods. The first method relies on radiologists' observations of images of an anthropomorphic phantom, and the second method was based on computer modeling of the imaging system using an anthropomorphic voxel phantom. The tube voltage was varied within a broad range (50-150 kV), including those values typically used with screen-film radiography. The tube charge was altered so that the same effective dose was achieved for each projection. Two x-ray units were employed using a computed radiography (CR) image detector with standard tube filtration and antiscatter device. Clinical image quality was assessed by a group of radiologists using a visual grading analysis (VGA) technique based on the revised CEC image criteria. Physical image quality was derived from a Monte Carlo computer model in terms of the signal-to-noise ratio, SNR, of anatomical structures corresponding to the image criteria. Both the VGAS (visual grading analysis score) and SNR decrease with increasing tube voltage in both chest PA and pelvis AP examinations, indicating superior performance if lower tube voltages are employed. Hence, a positive correlation between clinical and physical measures of image quality was found. The pros and cons of using lower tube voltages with CR digital radiography than typically used in analog screen-film radiography are discussed, as well as the relevance of using VGAS and quantum-noise SNR as measures of image quality in pelvis and chest radiography.

Algorithms↗

Inter-observer variation in masked and unmasked images for quality evaluation of clinical radiographs.

PURPOSE: To investigate the influence of masking on the inter-observer variation in image quality evaluation of clinical radiographs of chest and lumbar spine. BACKGROUND: Inter-observer variation is a big problem in image quality evaluation since this variation is often much bigger than the variation in image quality between, for example, two radiographic systems. In this study, we have evaluated the effect of masking on the inter-observer variation. The idea of the masking was to force every observer to view exactly the same part of the image and to avoid the effect of the overall 'first impression' of the image. A discussion with a group of European expert radiologists before the study indicated that masking might be a good way to reduce the inter-observer variation. METHODS: Five chest and five lumbar spine radiographs were collected together with detailed information regarding exposure conditions. The radiographs were digitised with a high-performance scanner and five different manipulations were performed, simulating five different exposure conditions. The contrast, noise and spatial resolution were manipulated by this method. The images were printed onto the film and the individual masks were produced for each film, showing only the parts of the images that were necessary for the image quality evaluation. The quality of the images was evaluated on ordinary viewing boxes by a large group of experienced radiologists. The images were examined with and without the masks with a set of image criteria (if fulfilled, 1 point; and not fulfilled, 0 point), and the mean score was calculated for each simulated exposure condition. RESULTS: The results of this study indicate that-contrary to what was supposed-the inter-observer variation increased when the images were masked. In some cases, especially for chest, this increase was statistically significant. CONCLUSIONS: Based on the results of this study, image masking in studies of fulfilment of image criteria cannot be recommended.

Computers↗

Optimisation of image plate radiography with respect to tube voltage.

PURPOSE: To find the tube voltage that results in the highest image quality per effective dose unit for chest and pelvis radiography, respectively, using image plates. METHODS: Two anthropomorphic phantoms (chest and pelvis) were imaged with several different tube voltages. The mA s settings were chosen so that the effective dose to the phantom was the same, regardless of the tube voltage, for the two examinations, respectively. The quality of the images was evaluated by six experienced radiologists using visual grading analysis. RESULTS: For both the chest and the pelvis examinations, the image quality increased when the tube voltage was reduced compared with the standard settings (125 and 70 kV for chest and pelvis, respectively), which were used for screen-film radiography previously. CONCLUSIONS: The image quality of image plate radiography can be increased by lowering the tube voltage compared with the one that was used for screen-film radiography.

Humans↗

Method of simulating dose reduction for digital radiographic systems.

The optimisation of image quality vs. radiation dose is an important task in medical imaging. To obtain maximum validity of the optimisation, it must be based on clinical images. Images at different dose levels can then either be obtained by collecting patient images at the different dose levels sought to investigate-including additional exposures and permission from an ethical committee-or by manipulating images to simulate different dose levels. The aim of the present work was to develop a method of simulating dose reduction for digital radiographic systems. The method uses information about the detective quantum efficiency and noise power spectrum at the original and simulated dose levels to create an image containing filtered noise. When added to the original image this results in an image with noise which, in terms of frequency content, agrees with the noise present in an image collected at the simulated dose level. To increase the validity, the method takes local dose variations in the original image into account. The method was tested on a computed radiography system and was shown to produce images with noise behaviour similar to that of images actually collected at the simulated dose levels. The method can, therefore, be used to modify an image collected at one dose level so that it simulates an image of the same object collected at any lower dose level.

Algorithms↗

A software tool for increased efficiency in observer performance studies in radiology.

Observer performance studies are time-consuming tasks, both for the participating observers and for the scientists collecting and analysing the data. A possible way to optimise such studies is to perform them in a completely digital environment. A software tool-ViewDEX (Viewer for Digital Evaluation of X-ray images)-has been developed in Java, enabling it to function on almost any computer. ViewDEX is designed to handle several types of studies, such as visual grading analysis (VGA), image criteria scoring (ICS) and receiver operating characteristics (ROC). The results from each observer are saved in a log file, which can be exported for further analysis in, for example, a special software for analysing ROC results. By using ViewDEX for an ROC experiment, an evaluation rate of approximately 200 images per hour can be achieved, compared to approximately 25 images per hour using hard copy evaluation. The results are obtained within minutes of completion of the viewing. The risk of human errors in the process of data collection and analysis is also minimised. The viewer has been used in a major trial containing approximately 2700 images.

Computer Simulation↗

Evaluation of image quality of lumbar spine images: a comparison between FFE and VGA.

PURPOSE: The aim of the present study is to compare two different methods for evaluation of the quality of clinical X-ray images. METHODS: Based on fifteen lumbar spine radiographs, two new sets of images were created. A hybrid image set was created by adding two distributions of artificial lesions to each original image. The image quality parameters spatial resolution and noise were manipulated and a total of 210 hybrid images were created. A set of 105 disease-free images was created by applying the same combinations of spatial resolution and noise to the original images. The hybrid images were evaluated with the free-response forced error experiment (FFE) and the normal images with visual grading analysis (VGA) by nine experienced radiologists. RESULTS: In the VGA study, images with low noise were preferred over images with higher noise levels. The alteration of the MTF had a limited influence on the VGA score. For the FFE study, the visibility of the lesions was independent of the sharpness and the noise level. No correlation was found between the two image quality measures. CONCLUSIONS: FFE is a precise method for evaluation of image quality, but the results are only valid for the type of lesion used in the study, whereas VGA is a more general method for clinical image quality assessment. The results of the FFE study indicate that there might be a potential to lower the dose levels in lumbar spine radiography without losing important diagnostic information.

Calibration↗

Nodule detection in digital chest radiography: summary of the RADIUS chest trial.

As a part of the Europe-wide research project 'Unification of physical and clinical requirements for medical X-ray imaging'-governed by the Radiological Imaging Unification Strategies (RADIUS) Group-a major image quality trial was conducted by members of the group. The RADIUS chest trial aimed at thoroughly examining various aspects of nodule detection in digital chest radiography, such as the effects of nodule location, system noise, anatomical noise, and anatomical background. The main findings of the RADIUS chest trial concerning the detection of a lung nodule with a size in the order of 10 mm can be summarised as: (1) the detectability of the nodule is largely dependent on its location in the chest, (2) the system noise has a minor impact on the detectability at the dose levels used today, (3) the disturbance of the anatomical noise is larger than that of the system noise but smaller than that of the anatomical background and (4) the anatomical background acts as noise to a large extent and is the major image component affecting the detectability of the nodule.

Artifacts↗

Nodule detection in digital chest radiography: introduction to the RADIUS chest trial.

Most digital radiographic systems of today have wide latitude and are hence able to provide images with a small constraint on dose level. This opens up for an unprejudiced dose optimisation. However, in order to succeed in the optimisation task, good knowledge of the imaging and detection processes is needed. As a part of the European-wide research project 'unification of physical and clinical requirements for medical X-ray imaging'-governed by the Radiological Imaging Unification Strategies (RADIUS) Group-a major image quality trial was conducted by members of the group. The RADIUS chest trial was focused on the detection of lung nodules in digital chest radiography with the aims of determining to what extent (1) the detection of a nodule is dependent on its location, (2) the system noise disturbs the detection of lung nodules, (3) the anatomical noise disturbs the detection of lung nodules and (4) the image background and anatomical background act as pure noise for the detection of lung nodules. The purpose of the present paper is to give an introduction to the trial and describe the framework and set-up of the investigation.

Artifacts↗