PubMed Health⌕ Search

Biomedical subjects

András Guttman

Publications and source records attributed to András Guttman.

14 recordsLinked to original sources

Micropreparative capillary gel electrophoresis of DNA: rapid expressed sequence tag library construction.

A capillary gel electrophoresis based automated DNA fraction collection technique was developed to support a novel DNA fragment-pooling strategy for expressed sequence tag (EST) library construction. The cDNA population is first cleaved by BsaJ I and EcoR I restriction enzymes, and then subpooled by selective ligation with specific adapters followed by polymerase chain reaction (PCR) amplification and labeling. Combination of this cDNA fingerprinting method with high-resolution capillary gel electrophoresis separation and precise fractionation of individual cDNA transcript representatives avoids redundant fragment selection and concomitant repetitive sequencing of abundant transcripts. Using a computer-controlled capillary electrophoresis device the transcript representatives were separated by their size and fractions were automatically collected in every 30 s into 96-well plates. The high resolving power of the sieving matrix ensured sequencing grade separation of the DNA fragments (i.e., single-base resolution) and successful fraction collection. Performance and precision of the fraction collection procedure was validated by PCR amplification of the collected DNA fragments followed by capillary electrophoresis analysis for size and purity verification. The collected and PCR-amplified transcript representatives, ranging up to several hundred base pairs, were then sequenced to create an EST library.

Animals↗

Transcription factor binding study by capillary zone electrophoretic mobility shift assay.

Regulation of gene expression through interaction of proteins with specific DNA sequences is a central issue in functional genomics. Capillary electrophoretic mobility shift assay is an efficient novel method for the investigation of sequence specific protein-DNA interactions, allowing rapid and sensitive quantification of the complex formation. In this paper, we present a pilot study on capillary zone electrophoretic mobility shift assay (CZEMSA) to investigate the interaction between the transcription factors of HeLa nuclear extract and Sp1-specific fluorescein-labeled oligonucleotide, using the unlabeled probe as competitor. The mobility shift assay was accomplished by CZE in coated capillaries without polymeric buffer additives. Specificity of the DNA protein complex formation was verified by competition experiments, as well as by supershift assay with an anti-Sp1 antibody. The applied electric field strength did not affect the stability of DNA-protein complex during the electrophoretic analysis, allowing rapid identification and quantification of the protein DNA interaction. A practical application to study the interaction between Oryza sativa MADS-box transcription factor 4 (OsMADS4) and its consensus sequence is also reported.

Base Sequence↗

Micromachined capillary cross-connector for high-precision fraction collection.

A new approach for high-precision fraction collection of double-stranded DNA fragments by capillary electrophoresis coupled to a micromachined plastic capillary cross-connector is presented. The system design integrates four fused-silica capillaries with an acrylic cross-channel connector. The cross-channel structure was introduced to enhance the efficiency of the fraction collection process by electrokinetic manipulations. Following the detection of the sample zone of interest at or slightly upstream of the cross during the separation mode, the potentials were reconfigured to collection mode to direct the selected analyte zone into the corresponding collection vial, while keeping the rest of the sample components virtually stopped within the separation capillary. In this way the spacing between consecutive bands of interest can be physically increased, allowing precise isolation of spatially close sample zones. After collection of the target fraction the separation mode is resumed, and the separation/collection cycle is repeated until all desired sample zones are separated and captured. The capillary cross-connector was fabricated of a transparent acrylic substrate by microdrilling flat end and through channels, matching precisely the O.D. and I.D. of the connected capillary tubing, respectively. This design provided a close to zero dead volume connection assembly for the separation and collection capillaries causing minimal extra band broadening during high-precision micropreparative DNA fractionation.

Electrophoresis, Capillary↗

Micropreparative fraction collection in microfluidic devices.

Micropreparative fraction collection following microchip-based electrophoretic analysis of biomolecules is of major importance for a variety of biomedical applications. In this paper, we present a microfabricated device-based fraction collection system. Various size DNA fragments were separated and collected by simply redirecting the desired portions of the detected sample zones to corresponding collection wells using appropriate voltage manipulations. The efficiency of sampling and collection of the fractions was enhanced by placing a cross channel at or downstream of the detection point. Following the detection of the band of interest, the potentials were reconfigured to sampling/collection mode, so that the selected sample zone migrated to the appropriate collection well of the microdevice. The potential distribution assured that the rest of the analyte components in the separation column was retarded, stopped, or reversed, increasing in this way the spacing between the sample zone being collected and the immediately following one. By this means, a precise collection of spatially close consecutive bands could be facilitated. Once the target sample fraction reached the corresponding collection well, the potentials were switched back to separation mode. Alternation of the separation/detection and sampling/collection cycles was repeated until all required sample zones were physically isolated. The integrated device consists of a sample introduction, separation, fraction sampling, and fraction collection compartments. The feasibility of the fraction collection technique was tested on a mixture of dsDNA fragments. The amounts of DNA collected in this way were enough for further downstream sample processing, such as conventional PCR-based analysis.

Chemical Fractionation↗

Bioanalysis in microfluidic devices.

Microfabricated bioanalytical devices (also referred to as laboratory-on-a-chip or micro-TAS) offer highly efficient platforms for simultaneous analysis of a large number of biologically important molecules, possessing great potential for genome, proteome and metabolome studies. Development and implementation of microfluidic-based bioanalytical tools involves both established and evolving technologies, including microlithography, micromachining, micro-electromechanical systems technology and nanotechnology. This article provides an overview of the latest developments in the key device subject areas and the basic interdisciplinary technologies. Important aspects of DNA and protein analysis, interfacing issues and system integration are all thoroughly discussed, along with applications for this novel "synergized" technology in high-throughput separations of biologically important molecules. This review also gives a better understanding of how to utilize these technologies as well as to provide appropriate technical solutions to problems perceived as being more fundamental.

Chemistry Techniques, Analytical↗

Rapid microwell polymerase chain reaction with subsequent ultrathin-layer gel electrophoresis of DNA.

Large-scale genotyping, mapping and expression profiling require affordable, fully automated high-throughput devices enabling rapid, high-performance analysis using minute quantities of reagents. In this paper, we describe a new combination of microwell polymerase chain reaction (PCR) based DNA amplification technique with automated ultrathin-layer gel electrophoresis analysis of the resulting products. This technique decreases the reagent consumption (total reaction volume 0.75-1 microL), the time requirement of the PCR (15-20 min) and subsequent ultrathin-layer gel electrophoresis based fragment analysis (5 min) by automating the current manual procedure and reducing the human intervention using sample loading robots and computerized real time data analysis. Small aliquots (0.2 microL) of the submicroliter size PCR reaction were transferred onto loading membranes and analyzed by ultrathin-layer gel electrophoresis which is a novel, high-performance and automated microseparation technique. This system employs integrated scanning laser-induced fluorescence-avalanche photodiode detection and combines the advantages of conventional slab and capillary gel electrophoresis. Visualization of the DNA fragments was accomplished by "in migratio" complexation with ethidium bromide during the electrophoresis process also enabling real time imaging and data analysis.

Automation↗

Direct haplotype detection of adjacent polymorphic sites in the regulatory region of the dopamine D4 receptor (DRD4) gene.

A novel method of haplotype identification is discussed allowing simultaneous detection of two adjacent polymorphic sites, a single nucleotide polymorphism (SNP) and a length polymorphism within 1-2 kilobase distance. The method combines allele specific-amplification with high-throughput, automated ultrathin-layer gel electrophoresis analysis of fragment size polymorphism. A typical application is shown for genotyping the -521 C/T single nucleotide polymorphism and the 120 bp duplication in the 5"-upstream region of the dopamine D4 receptor (DRD4) gene. We have also demonstrated that the haplotypes of double heterozygotes for -521 C/T and for the 120 bp duplication can be clearly distinguished, that has only been possible previously by extensive pedigree analysis.

Binding Sites↗

Membrane-mediated ultrafast restriction digestion and subsequent rapid gel microchip electrophoresis of DNA.

Ultrafast, membrane-mediated restriction digestion of DNA molecules followed by rapid gel microchip electrophoresis of the resulting fragments is described. Combination of restriction endonuclease digestion on small pore-size microfibrous membranes with sample loading and electrophoresis analysis in a multilane (up to 96) format resulted in very fast restriction digest based microscale DNA analysis. Complete digestion of several nanogram target DNA was accomplished on the microporous membrane at room temperature just in a few minutes with a single or a combination of various restriction enzymes, using only submicroliter quantities of samples and reagents. The reaction mixture containing membrane also served as sample loading device for the subsequent gel microchip electrophoresis based analysis. This work establishes methods for high-speed, high-throughput DNA analysis, featuring extremely low sample and reagent consumption, and fast restriction digestion in combination with sample loading and rapid gel microchip analysis of the resulting fragments. The entire restriction digestion, sample loading and electrophoresis analysis process required less than 20 min.

Bacteriophage phi X 174↗

Rapid two-dimensional analysis of proteins by ultra-thin layer gel electrophoresis.

Identification of qualitative and/or quantitative protein expression differences as well as characterization of specific cell proteomes would further advance molecular cell biology research. Today, one of the most commonly used tools for proteome analysis is two-dimensional gel electrophoresis. Although this technology is informative, it is extremely cumbersome, time-consuming and lacks automation and proper reproducibility. In this paper, we propose an automated separation/detection system capable of rapid two-dimensional analysis of proteins by ultra-thin layer gel electrophoresis with real time imaging of the separated components, using fiber optics based laser induced fluorescence technology. The approach is based on electric field mediated separation in capillary dimensions, along with noncovalent, "in migratio" fluorescent staining methodology. The advantage of the technology discussed over existing techniques is its simplicity, speed and good detection sensitivity.

Animals↗

Microfabricated devices in biotechnology and biochemical processing.

In the past few years, interdisciplinary science and technologies have converged to create exciting challenges and opportunities, which involve a new generation of integrated microfabricated devices. These new devices are referred to as 'lab-on-a-chip' or Micro Total Analysis Systems. Their development involves both established and evolving technologies, which include microlithography, micromachining, Micro Electro Mechanical Systems technology, microfluidics and nanotechnology. This review summarizes the key device subject areas and the basic interdisciplinary technologies, and gives a better understanding of how these technologies can be used to provide appropriate technical solutions to fundamental problems. Important applications for this novel 'synergized' technology in chemical and biotechnological processing, in addition to the application of simulation methods in the development of microfabricated devices, will also be discussed.

Bioreactors↗

Microchip-based high-throughput screening analysis of combinatorial libraries.

In recent years, there have been significant advances in biochemical assay miniturization and integration of microchip-based technologies with combinatorial library screening for high-throughput and large-scale applications. Small-molecule microarrays, protein arrays and cell-based arrays and conventional DNA arrays as well as microfluidic approaches in HTS are discussed in this review.

Animals↗