Real-time gating system for mouse cardiovascular MR imaging.

Mouse cardiac MR gating using ECG is affected by the hostile MR environment. It requires appropriate signal processing and correct QRS detection, but gating software methods are currently limited. In this study we sought to demonstrate the feasibility of digital real-time automatically updated gating methods, based on optimizing a signal-processing technique for different mouse strains. High-resolution MR images of mouse hearts and aortic arches were acquired using a chain consisting of ECG signal detection, digital signal processing, and gating signal generation modeled using Simulink (The MathWorks, Inc., Natick, MA, USA). The signal-processing algorithms used were respectively low-pass filtering, nonlinear passband, and wavelet decomposition. Both updated and nonupdated gating signal generation methods were tested. Noise reduction was assessed by comparison of the ECG signal-to-noise ratio (SNR) before and after each processing step. Gating performance was assessed by measuring QRS detection accuracy before and after online trigger-level adjustments. Low-pass filtering with trigger-level adjustment gave the best performance for mouse cardiovascular imaging using gradient-echo (GE), spin-echo (SE), and fast SE (FSE) sequences with minimum induced delay and maximum gating efficiency (99% sensitivity and R-peak detection). This simple digital gating interface will allow various gating strategies to be optimized for cardiovascular MR explorations in mice.

Algorithms↗

Reference signal extraction from corrupted ECG using wavelet decomposition for MRI sequence triggering: application to small animals.

BACKGROUND: Present developments in Nuclear Magnetic Resonance (NMR) imaging techniques strive for improved spatial and temporal resolution performances. However, trying to achieve the shortest gradient rising time with high intensity gradients has its drawbacks: It generates high amplitude noises that get superimposed on the simultaneously recorded electrophysiological signals, needed to synchronize moving organ images. Consequently, new strategies have to be developed for processing these collected signals during Magnetic Resonance Imaging (MRI) examinations. The aim of this work is to extract an efficient reference signal, from an electrocardiogram (ECG) that was contaminated by the NMR artefacts. This may be used for image triggering and/or cardiac rhythm monitoring. METHODS: Our method, based on sub-band decomposition using wavelet filters, is tested on various ECG signals recorded during three imaging sequences: Gradient Echo (GE), Fast Spin Echo (FSE) and Inversion Recovery with Spin Echo (IRSE). In order to define the most adapted wavelet functions to use according to the excitation protocols, noise generated by each imaging sequence is recorded and analysed. After exploring noise models along with information found in the literature, a group of 14 wavelets, members of three families (Daubechies, Coiflets, Symlets), is selected for the study. The extraction process is carried out by decomposing the contaminated ECG signals into 8 scales using a given wavelet function, then combining the sub-bands necessary for cardiac synchronization, i.e. those containing the essential part of the QRS energy, to construct a reference signal. RESULTS: The efficiency of the presented method has been tested on a group of quite representative signals containing: highly contaminated (mean SNR<--5 dB) simulated ECGs that replicate normal and pathological human heart beats, as well as some pathological and healthy rodents' actual ECG records. Despite the weak SNR of the contaminated ECG, the performances were quite satisfactory. When comparing the wavelet performances, one may notice that for a given sequence, some wavelets are more efficient for processing than others; for GE, FSE and IRSE sequence, good synchronisation condition is accomplished with coif5, sym8, and sym4 respectively. CONCLUSION: Sub-band decomposition proved to be very suitable for extracting a reference signal from a corrupted ECG for MRI triggering. An appropriate choice of the wavelet function, in accordance with the image sequence type, could considerably improve the quality of the reference signal for better image synchronization.

Algorithms↗

Sucrose solution freezing studied by magnetic resonance imaging.

Ice formation of a 20% w/v sucrose solution was monitored during the freezing process by magnetic resonance imaging (MRI). An original experimental setup was designed with oil as a cooling fluid that allows accurate control of the temperature. The NMR signal intensity of particular sampled volumes was observed during the entire cooling period, from 0 to -50 degrees C, showing a peak characteristic to a transition before the loss of the signal. Moreover, spatial ice distribution of the frozen matrix was observed by high resolution MRI with an isotropic resolution of 78x78x78microm(3). MRI has proved to be a novel technique for determining the glass transition temperature of frozen sucrose solutions, in the concentration range where calorimetric measurements are not feasible.

Freezing↗

In vivo magnetic resonance imaging of large spontaneous aortic aneurysms in old apolipoprotein E-deficient mice.

UNLABELLED: Old ApoE-deficient mice were studied in vivo by magnetic resonance imaging (MRI) to prospectively evaluate vascular remodeling associated with atherosclerotic lesions. MATERIAL AND METHODS: Old female ApoE-/- mice on a normal diet were followed by MRI at 2 Tesla for a 3-month period and killed for histopathology. Aortic dimensions were measured and compared. RESULTS: High-quality in vivo MR images were obtained at 2 Tesla with in plane spatial resolution of 86 X 86 microm2. On MRI, aortic lumen enlargement (>1.5-fold dilation) was seen in 10 of 13 mice, located predominantly in the suprarenal portion of the aorta. The mean maximal diameter of the aneurysms and of the aorta above and below the aneurysm were, respectively, 1.12 +/- 0.32 mm and 0.53 +/- 0.08 mm by MRI and 1.3+/- 0.41 mm and 0.55 +/- 0.15 mm by histology. Matched histologic cross-sections of the aortic wall showed medial degradation with rupture of the internal elastic lamina at multiple sites, associated with fibrolipidic plaque containing cholesterol crystals. CONCLUSIONS: Aortic lumen enlargement was diagnosed in old ApoE-/- mice at sites with advanced atherosclerotic plaques. MRI has potential both as an in vivo imaging technique for screening mouse models for vascular wall pathology and to follow arterial remodeling associated with the disease progression.

Age Factors↗

Kinetics of anaerobic metabolism in human skeletal muscle: influence of repetitive high-intensity exercise on sedentary dominant and non-dominant forearm. A 31P NMR study.

Potential differences were assessed between the dominant (D) and non-dominant (ND) forearms of sedentary subjects during anaerobic exercise. Subjects performed voluntary concentric contractions of D and ND forearm muscle during a series of three high-intensity (60% of the maximal voluntary contraction force (MVC)) exercise bouts. The time-dependent changes in intracellular pH (pH(i)), Pi, and PCr concentrations, and their relation to muscular work were examined using 31P magnetic resonance spectroscopy (MRS) techniques, and revealed that D forearm metabolic kinetics in sedentary individuals are improved during repetitive high-intensity exercise compared to their respective ND forearm muscle. We postulate that the more regular and preferential utilization of the D limb leads to a "trained-like" condition.

Adult↗

Retrospective intra-scan motion correction.

This paper analyzes the effects of intra-scan motion and demonstrates the possibility of correcting them directly in k-space with a new automatic retrospective method. The method is presented for series of 2D acquisitions with Cartesian sampling. Using a reference k-space acquisition (corrected for translations) within the series, intra-scan motion parameters are accurately estimated for each trajectory in k-space of each data set in the series resulting in pseudo-random sample positions. The images are reconstructed with a Bayesian estimator that can handle sparse arbitrary sampling in k-space and reduces intra-scan rotation artefacts to the noise level. The method has been assessed by means of a Monte Carlo study on axial brain images for different signal-to-noise ratios. The accuracy of motion estimates is better than 0.1 degrees for rotation, and 0.1 and 0.05 pixel, respectively, for translation along the read and phase directions for signal-to-noise ratios higher than 6 of the signals on each trajectory. An example of reconstruction from experimental data corrupted by head motion is also given.

Algorithms↗

Trabecular alveolar bone in the human mandible: a dual-energy x-ray absorptiometry study.

OBJECTIVE: The purpose of this study was to evaluate the potential use of dual energy x-ray absorptiometry for the assessment of bone mineral content and bone mineral density before implant placement. MATERIALS AND METHODS: The material examined consisted of 63 mandibular bone specimens cut from 21 fresh cadavers (11 men; 10 women). Three specimens were cut per cadaver in the incisal, premolar, and molar regions. Three regions of interest (G, R1, and R2) were delineated. The global bone specimen (G) consisted of the whole specimen (ie, both cortical and trabecular bone). R1 and R2 were delineated in the trabecular bone of the alveolar process. RESULTS: In all subjects, the combined bone mineral content of the whole mandible specimens (global bone mineral content) was significantly correlated with age. The difference between the mean bone mineral densities of the male and female mandibles was found to be significant for G (P = .009). The mean bone mineral densities of dentate and edentulous specimens were also found to be significantly different for G and R1, respectively (P = .001 and P = .02), but not for R2. A positive correlation could be detected among the mean bone mineral density of G and R1, G and R2, and R1 and R2 of (1) male and female specimens, (2) dentate and edentulous specimens, and (3) incisal, premolar, and molar specimens. CONCLUSIONS: The intra-alveolar trabecular bone of these 21 mandibles is affected by the same local and systemic influences as cortical bone, whereas the infra-alveolar trabecular bone is mostly sensitive to dental status. The cortical and trabecular bone of the 10 mandibles from women is more sensitive to systemic influences, whereas that from men is more sensitive to local influences. This is somewhat in agreement with some studies that found an association between osteoporosis and oral bone loss, which is a metric measure.

Absorptiometry, Photon↗

High-resolution magnetic resonance imaging at 2 Tesla: potential for atherosclerotic lesions exploration in the apolipoprotein E knockout mouse.

INTRODUCTION: The aim of the present study was to evaluate the potential of high-resolution MRI at 2 Tesla (T) for direct noninvasive imaging of the aortic wall in a mouse model of atherosclerosis. MATERIAL AND METHODS: A specific mouse antenna was developed and sequence parameters were adjusted. T(1)- and T2-weighted images of abdominal aorta were obtained at 2 T with a spatial resolution of 86 x 86 x 800 microm3 in vivo. With a dedicated small coil, ex vivo MRI of the aorta was performed with a spatial resolution of 54 x 54 x 520 microm3. RESULTS: In vivo, the aortic wall was clearly defined on T(2)-weighted images in 15 of 16 mice: along the aorta the lumen circumference ranged from 1.07 to 3.61 mm and mean wall thickness from 0.11 to 0.67 mm. In vivo measurements of plaque distribution were confirmed by ex vivo MR imaging and by histology, with a good correlation with histology regarding lumen circumference (r = 0.94) and wall thickness (r = 0.97). CONCLUSION: Magnetic resonance imaging at 2 T to analyze in vivo atherosclerotic lesions in mice is possible with a spatial resolution of 86 x 86 x 800 microm3 and thus can be used for noninvasive follow-up in evaluation of new drugs.

Animals↗

[NMR radiofrequency microcoil design: usefulness of electromagnetic simulation].

The extraction of the Nuclear Magnetic Resonance (NMR) spectra of samples having smaller and smaller volumes is a real challenge. Either these reductions of volume are dictated by the difficulties of production of sufficiently large samples or by necessities of miniaturisation of the analysing system, in both cases a careful design of the radiofrequency coil, ensuring an optimum reception of the NMR signal, is required. We have also evaluated the usefulness of electromagnetic simulation software for the design and optimisation of these radio-frequency coils, which are more and more used in biology and health research projects.

Electromagnetic Fields↗