Elongation and structural properties of meniscal repair using suture techniques in distraction and shear force scenarios: biomechanical evaluation using a cyclic loading protocol.

BACKGROUND: Most biomechanical studies on meniscal repairs have focused on testing distraction scenarios to evaluate structural properties of the repaired meniscus. An application of shear forces might replicate the in vivo situation more closely. HYPOTHESIS: In the shear force scenario, meniscal repair using a vertical suture technique will result in significantly less elongation when subjected to a cyclic loading protocol than that resulting from a horizontal suture technique. STUDY DESIGN: Controlled laboratory study. METHODS: In fresh-frozen porcine menisci (n = 10 in each group), horizontal and vertical 2.0 Ethibond suturing techniques were tested in distraction and shear force scenarios. Elongation after 1000 cycles between 5 and 20 N and the structural properties such as stiffness, yield load, maximum load to failure, and failure mode were evaluated using a testing machine at a rate of 12.5 mm/s. RESULTS: In the distraction force scenario, no statistically significant difference in elongation after cyclic loading was found between specimens repaired with vertical or horizontal suture techniques. After 1000 cycles of cyclic loading in the shear force scenario, the horizontal suturing revealed significantly less elongation (2.8 +/- 1.1 mm) than did the vertical suture technique (4.6 +/- 2.0 mm). No statistically significant difference in yield and maximum load was found (P > .05). CONCLUSION: The results of the present study do not support the authors' hypothesis. In the shear force test, horizontal sutures were superior to vertical suture techniques. CLINICAL RELEVANCE: Meniscal repair with horizontal suture techniques can withstand elongation due to shear forces more effectively than can vertical mattress sutures.

Animals↗

Importance of femoral tunnel placement in double-bundle posterior cruciate ligament reconstruction: biomechanical analysis using a robotic/universal force-moment sensor testing system.

BACKGROUND: Previous studies have identified the femoral attachment of the posterior cruciate ligament fibers as one of the primary determinants of fiber tension behavior. In addition, a double-bundle posterior cruciate ligament reconstruction has been shown to restore the intact knee kinematics more closely than does a single-bundle reconstruction. HYPOTHESIS: An anterior tunnel position in double-bundle posterior cruciate ligament reconstruction restores the biomechanics of the normal knee more closely than does a posterior tunnel position. STUDY DESIGN: Controlled laboratory study. METHODS: Kinematics and in situ forces of human knees after double-bundle posterior cruciate ligament reconstruction with 2 different femoral tunnel positions (anterior vs posterior) were evaluated using a robotic/universal force-moment sensor testing system. Within the same specimen, the resulting knee kinematics and in situ forces were compared. For statistical analysis, 2-way analysis of variance repeated measures were performed. RESULTS: The femoral tunnel position of the double-bundle hamstring graft had significant effect on the resulting posterior tibial displacement and in situ forces of the hamstring grafts. The anterior femoral tunnel position provided significantly less posterior tibial translation than did the posterior tunnel position. There was a tendency toward higher in situ forces of grafts fixed in the anterior tunnel when compared to the posterior position, but this difference was statistically not significant. CONCLUSION: An anterior position of the bone tunnels in double-bundle posterior cruciate ligament reconstruction restores the normal knee kinematics more closely than does a posterior position of the tunnels. CLINICAL RELEVANCE: In double-bundle posterior cruciate ligament reconstruction, posterior placement of the tunnel should be avoided.

Aged↗

Joint kinematics and in situ forces after single bundle PCL reconstruction: a graft placed at the center of the femoral attachment does not restore normal posterior laxity.

INTRODUCTION: Femoral tunnel placement has a great influence on the clinical outcome after PCL reconstruction. MATERIALS AND METHODS: Using a robotic/universal force moment sensor (UFS) testing system, we examined joint kinematics and in situ forces of human knees following soft-tissue single bundle PCL reconstruction fixed at the center of the femoral attachment. RESULTS: Posterior tibial translation significantly increased at all flexion angles after transsection of the posterior cruciate ligament (p<0.05). PCL reconstruction resulted in significantly less posterior tibial translation at all flexion angles when compared to the PCL deficient knee (p<0.05). The differences in the in situ force between the intact ligament and the reconstructed graft were statistical significant (p<0.05). CONCLUSION: Single bundle PCL reconstruction with a soft-tissue graft fixed at the center of the femoral attachment is able to reduce the posterior tibial translation significantly. However, it cannot restore kinematics of the intact knee and in situ forces of the intact PCL.

Aged↗

A controlled prospective case control study of a prevention training program in female team handball players: the German experience.

BACKGROUND: Few authors have investigated the effectiveness of preventive intervention in European team handball. PURPOSE: The aim of the present study was to evaluate the effects of a prevention program on the incidence of injuries in female European team handball players. STUDY DESIGN: Prospective controlled study. METHODS: Ten female handball teams (134 players) took part in the prevention program (1. Information about injury mechanism, 2. Balance-board exercises, 3. Jump training) while 10 other teams (142 players) were instructed to train as usual. Over one season all injuries were documented weekly. RESULTS: Ankle sprain was the most frequent diagnosis in both groups with 11 ankle sprains in the control group and 7 ankle sprains in the intervention group (Odds ratio: 0.55, 95% confidence interval: 0.22-1.43). The knee was the second frequent injury site. In the control group 5 of all knee injuries were anterior cruciate ligament (ACL) ruptures (incidence: 0.21 per 1000 h) in comparison with one in the intervention group (incidence: 0.04 per 1000 h). Odds ratio was 0.17 with 95% confidence interval of 0.02-1.5. CONCLUSIONS: This study confirms that proprioceptive and neuromuscular training is appropriate for the prevention of knee and ankle injuries among female European team handball players.

Adult↗

Primary stability of hamstring graft fixation with biodegradable suspension versus interference screws.

PURPOSE: During the early postoperative period, the stability of the fixation of a hamstring graft to the bone tunnel is the primary factor in limiting rehabilitation. The aim of this study was to evaluate if the initial fixation strength of a new suspension screw is comparable to that of the biodegradable interference screw fixation technique in the hamstring reconstruction of the anterior cruciate ligament (ACL). TYPE OF STUDY: Experimental laboratory study. METHODS: We evaluated the initial fixation strength of a biodegradable poly-L-lactide/tri-calcium phosphate (PLLA/TCP) screw that suspended the graft in the bone tunnel and compared it with the strength of an interference screw for fixation of hamstring grafts in ACL reconstruction using bovine knees. Single-cycle and cyclic loading tests were performed using a materials testing machine. RESULTS: The suspension screw provided a significantly higher yield load and ultimate failure load than the interference screw. There was no significant difference in the stiffness of both techniques. The typical failure mode for the suspension screw was fracture of the screw and for the interference screw it was slippage of the graft past the screw. In cyclic testing, both methods of fixation ran out to 1,000 cycles up to 250 N with a mean displacement of 2.6 mm (range, 1.8 to 3.3 mm) for the suspension screw and 4.1 mm (range, 2.3 to 6.0 mm) for the interference screw. Only the grafts fixed with the suspension screw survived a protocol with 1,000 cycles up to 400 N. CONCLUSIONS: Our biomechanical data suggest that hamstring graft fixation using a biodegradable PLLA/TCP suspension screw provides an alternative to interference screw fixation. CLINICAL RELEVANCE: Hamstring graft fixation using a suspension screw provides a reasonable alternative to interference screw fixation.

Absorbable Implants↗

Cyclic loading comparison between biodegradable interference screw fixation and biodegradable double cross-pin fixation of human bone-patellar tendon-bone grafts.

PURPOSE: The aim of this study was to compare ultimate load, yield load, stiffness, and displacement after cyclic loading of a cross-pin technique and an interference screw technique for the fixation of bone-patellar tendon-bone (BPTB) grafts in anterior cruciate ligament (ACL) reconstruction. TYPE OF STUDY: Biomechanical in vitro study. METHODS: The devices tested were 2 2.7-mm biodegradable pins (RigidFix; Ethicon, Mitek Division, Norderstedt, Germany) and biodegradable interference screws (Absolute; Innovasive Devices, Marlborough, MA). Each device was used for the fixation of 10 8-mm, 9-mm, or 10-mm sized human BPTB grafts in tunnels drilled in bovine knees. Ultimate load, yield load, stiffness, and displacement after cyclic loading (1,000 cycles between 50 and 250 N) were then evaluated. RESULTS: All 8-mm grafts that were fixed with cross-pins failed after a mean of 124 cycles of load. The 9-mm and 10-mm grafts survived the cyclic loading protocol. Yield load and maximum load of the 10-mm groups (cross-pin and interference screw) were significantly higher than that of the 9-mm groups. There was no significant difference in maximum load, yield load, and stiffness between the cross-pin and interference screw fixation technique for 1 graft size. CONCLUSIONS: The biomechanical data suggest that femoral fixation of 9-mm and 10-mm BPTB grafts using 2.7-mm biodegradable cross-pins leads to primary stability that is comparable to that of biodegradable interference screws. Fixation of 8-mm BPTB grafts using 2.7-mm biodegradable cross-pins had poor results. CLINICAL RELEVANCE: The diameter of the bone block is the limiting factor for the final fixation strength and the cyclical survival when using cross-pins. We strongly recommend not using this technique for bone blocks smaller than 9 mm in diameter.

Absorbable Implants↗

Cyclic testing of flexible all-inside meniscus suture anchors: biomechanical analysis.

BACKGROUND: Flexible meniscus repair devices are designed to combine the benefits of rigid all-inside meniscus anchors with the biomechanical properties of sutures. HYPOTHESIS: Stiffness and pull-out strength of flexible all-inside suture anchors and conventional sutures under cyclic loading conditions will be comparable. STUDY DESIGN: Controlled laboratory study. METHODS: In 50 fresh frozen bovine menisci, artificial meniscus lesions were repaired with different meniscus fixation techniques: horizontal and vertical FasT-Fix, RapidLoc, and horizontal and vertical 2-0 Ethibond sutures. The specimens were cycled 1000 times between 5 and 20 N and then loaded to failure. RESULTS: All devices survived the cyclic loading protocol. There was no significant difference in the displacement between all repair techniques tested (horizontal FasT-Fix, 6.23 mm; vertical FasT-Fix, 5.34 mm; RapidLoc, 6.84 mm; horizontal 2-0 Ethibond, 6.03 mm; vertical 2-0 Ethibond, 5.61 mm (P > .05). Vertical and horizontal FasT-Fix suture anchors had a significantly higher stiffness and pull-out strength (94.1 N and 80.8 N, respectively) than did horizontal sutures (50.2 N) and RapidLoc devices (30.3 N) (P > .05). CONCLUSIONS: In this study, flexible all-inside meniscus anchors (FasT-Fix) had higher pull-out strength than did conventional vertical suture techniques. Biomechanical characteristics of the flexible RapidLoc are comparable to those of horizontal sutures. CLINICAL RELEVANCE: Flexible all-inside meniscus repair devices are an alternative to conventional suture techniques.

Animals↗

Soft-tissue graft fixation in posterior cruciate ligament reconstruction: evaluation of the effect of tibial insertion site on joint kinematics and in situ forces using a robotic/UFS testing system.

INTRODUCTION: Surgical reconstruction of the posterior cruciate ligament (PCL) is recommended in acute injuries that result in severe tibial subluxation and instability. The surgical outcome level may be affected by the tibial fixation site. In response to a 110-N posterior tibial load, kinematics and in situ forces of anatomical soft-tissue graft fixation in single-bundle PCL reconstruction using an interference screw fixation are significantly closer to those in the intact knee than with extracortical fixation with two staples. MATERIALS AND METHODS: Using a robotic/universal force moment sensor (UFS) testing system, we examined joint kinematics and in situ forces of porcine knees following single-bundle PCL reconstruction fixed at two different tibial fixation sites: anatomical interference screw and extracortical fixation. RESULTS: The site of the tibial graft fixation had significant effect on the resulting posterior displacement and in situ forces of the graft. Both PCL reconstruction techniques reduced the posterior tibial translation significantly. Proximal fixation techniques provided significantly less posterior tibial translation than extracortical fixation. Single-bundle PCL reconstruction with an interference screw showed higher in situ forces of the graft than the extracortical fixation. CONCLUSIONS: The kinematics and in situ forces of a single-bundle PCL reconstruction using an interference screw fixation technique are superior to the primary stability of an extracortical fixation with staples.

Animals↗

Biomechanical evaluation of a new cross-pin technique for the fixation of different sized bone-patellar tendon-bone grafts.

To overcome the disadvantages of interference-screw fixation of bone-patellar tendon-bone (BPTB) grafts, new fixation techniques for anterior cruciate ligament (ACL) grafts using biodegradable pins have been developed. The hypothesis of the present study was that cross-pin fixation techniques provide a primary stability that is comparable to that of interference screws. A biomechanical in vitro study was discussed. Human BPTB grafts of 8, 9 and 10 mm diameter were fixed in bovine knees with biodegradable cross pins (diameter: 2.0, 2.7 or 3.2 mm) or biodegradable interference screws. Stiffness and ultimate load were evaluated. For 9 and 10 mm BPTB grafts, no statistically significant difference in maximum load and stiffness was found between the four fixation techniques tested. For 8 mm bone blocks the maximum load of the 3.2 mm pins (274.2 N) was significantly lower than for the 2.0 mm pins (479.8 N) and the interference screws (504.0 N). Predominant failure mode in this group was bone-block fracture. Thicker grafts (9 and 10 mm) fixed with the 2.0 mm pins predominantly failed by implant fracture. Femoral fixation of 8, 9 and 10 mm BPTB grafts using cross pins leads to biomechanical properties that are comparable to biodegradable interference screws when tested by a single-cycle load to failure. Cross pins provide a rigid fixation for 9 and 10 mm BPTB grafts.

Absorbable Implants↗

Initial fixation strength of flexible all-inside meniscus suture anchors in comparison to conventional suture technique and rigid anchors: biomechanical evaluation of new meniscus refixation systems.

BACKGROUND: The newest generation of meniscus repair devices is designed to combine the benefits of the all-inside technique with the biomechanical properties of sutures. HYPOTHESIS: New flexible all-inside suture anchors have better fixation strength than rigid anchors, but there is no difference when compared to conventional horizontal and vertical mattress sutures. STUDY DESIGN: Controlled laboratory study. METHODS: In fresh-frozen bovine menisci, initial fixation strength, stiffness, and failure mode of different meniscus fixation techniques (FastT-Fix, RapidLoc, Meniscus Arrow, horizontal and vertical 2.0 Ethibond sutures) were evaluated in a computer-based materials testing machine at a rate of 12.5 mm/sec. RESULTS: The vertical and horizontal FastT-Fix suture anchors were the strongest devices with regard to pullout strength, with no significant difference compared to the vertical 2-0 Ethibond sutures. Horizontal sutures, Meniscus Arrow, and RapidLoc had significantly lower pullout strength. Vertical and horizontal FastT-Fix suture anchors showed significantly higher stiffness than the other devices. CONCLUSIONS: Biomechanical properties of flexible all-inside meniscus anchors (FastT-Fix) are comparable to conventional vertical suture techniques. Characteristics of the flexible RapidLoc are comparable to rigid anchors (Meniscus Arrow). CLINICAL RELEVANCE: From the biomechanical point of view, flexible all-inside meniscus refixation devices are an alternative to conventional suture techniques and rigid meniscus anchors.

Animals↗

A new rigid biodegradable anchor for meniscus refixation: biomechanical evaluation.

All-inside repair devices have been developed to overcome the disadvantages of conventional suture techniques (such as vein and nerve damage and increased OR time). The Contour Meniscus Arrow is a second generation of the first biodegradable all-inside implant, the Meniscus Arrow. The aim of this study was to compare the biomechanical properties of the Contour Meniscus Arrow to the first-generation Meniscus Arrow and vertical or horizontal suture techniques. In fresh frozen bovine menisci, initial fixation strength, stiffness and failure mode of four different meniscus refixation techniques (Meniscus Arrow, Contour Meniscus Arrow, vertical and horizontal 2-0 Ethibond suture techniques) were evaluated in a computer-based material-testing machine at a rate of 12.5 mm/s. Vertical meniscus sutures showed the highest initial fixation strength, followed by the horizontal suture technique and the Contour Arrow. The Meniscus Arrow showed inferior pull-out strength. Subjecting the different refixation techniques to cyclic testing decreased the fixation strength in all groups. The modified Meniscus Anchor (Contour Arrow) provides biomechanical properties that are superior (pull-out strength) or similar (stiffness) compared to the first biodegradable all-inside implant, the Meniscus Arrow. The pull-out strength of the Contour Arrow was comparable to the pull-out strength reported for horizontal meniscus sutures in the literature. These biomechanical characteristics of this new implant justify clinical use.

Absorbable Implants↗

Primary stability of bone-patellar tendon-bone graft fixation with biodegradable pins.

PURPOSE: We evaluated the initial bone-patellar tendon-bone (BPTB) graft fixation strength of biodegradable pins compared with interference screws in anterior cruciate ligament reconstruction using bovine knees. TYPE OF STUDY: Biomechanical in vitro study. METHODS: Ten BPTB grafts from human donors fixed with 2 biodegradable 2.7-mm pins (Rigid Fix; Ethicon, Mitek Division, Norderstedt, Germany) crossing the bone block perpendicular and 10 BPTB grafts fixed with conventional biodegradable interference screws (Absolute Absorbable Interference Screw; Innovasive Devices, Marlborough, MA) underwent ultimate single-cycle failure loading at a rate of 200 mm/min. The grafts were fixed to bovine tibia to simulate young human femoral bone density. Failure mode, displacement before failure, and ultimate failure load were tested with a testing machine. The pullout force was in line with the bone tunnel to simulate a worst case scenario. RESULTS: The failure mode for cross pins was either fracture of the bone block (5 specimens) or fracture of the articular pin (5 specimens). The failure mode for interference screws was slippage past the screw in all specimens. In the single cycle loading test, the mean yield load for the biodegradable pins was 400.2 (+/- 122.4) N, maximum load, 524.6 (+/- 136.6) N, with a mean stiffness of 155.2 (+/- 32.4) N/mm. The yield load at failure for the interference screw was 402.7 (+/- 143.9) N, maximum load 515.7 (+/- 168.5) N with a mean stiffness of 168 (+/- 42) N/mm. CONCLUSIONS: Fixation of a BPTB graft with 2 biodegradable 2.7-mm pins (Rigid Fix) leads to primary stability that is comparable to fixation with biodegradable interference screws.

Absorbable Implants↗

Initial fixation strength of two bioabsorbable pins for the fixation of hamstring grafts compared to interference screw fixation: single cycle and cyclic loading.

BACKGROUND: During the early postoperative period, the fixation of a hamstring graft to the bone tunnel is the primary factor in limiting rehabilitation. HYPOTHESIS: The initial fixation strength of a double cross pin fixation technique is comparable with the biodegradable interference screw fixation technique. STUDY DESIGN: Experimental laboratory study. METHODS: The authors examined the initial fixation strength of two 3.3-mm bioabsorbable pins compared to interference screws for hamstring grafts in bovine knees. RESULTS: Analysis of yield load, maximum load, and stiffness in the single-cycle loading test showed no statistically significant differences for cross pin and interference fixation (P <.05). For cross pins and interference screws, the mean displacement under 1000 cycles to 250 N was 5.07 ( +/- 1.9) mm and 4.81 ( +/- 2.5) mm, stiffness 252 ( +/- 78) N/mm and 289 ( +/- 148) N/mm. Only grafts fixed with cross pins survived 1000 cycles to 450 N. CONCLUSION: The initial fixation strength of the double cross pin technique is comparable to that of interference screw fixation with a stiffness comparable to that of the native ACL. CLINICAL RELEVANCE: Hamstring graft fixation using two cross pins provides an alternative to bioabsorbable interference screw fixation.

Absorbable Implants↗