Methods for reducing cutting temperature in ultrasonic cutting of bone.

Ultrasonic cutting is widely used in food processing applications to produce a clean and accurate cut. However, it is yet to be adopted as an instrument of choice in orthopaedic applications, mainly due to the high temperatures that can be generated at the cut site and the consequent requirement to use additional cooling. For example, if cutting temperatures above 55-60 degrees C are reached, particularly for sustained periods, bone necrosis can occur, compromising post-operative recovery. A recent study by the authors has shown that the thermal response in natural materials, such as wood and bone, is affected by the absorption of ultrasonic energy and conduction of heat from the cut site. In this paper the dependency of cutting parameters, such as blade tip vibration velocity, applied load, tuned frequency and coupling contact conditions, on the thermal response are reported and results show that it is possible to maintain cutting temperatures within safety limits by controlling the cutting parameters. A novel cutting blade design is proposed that reduces frictional heat generated at the cut site. Through a series of experimental investigations using fresh bovine femur it is demonstrated that the cutting temperature, and hence thermal damage, can be reduced by selecting appropriate cutting parameters and blade profile.

Animals↗

A finite element model for ultrasonic cutting.

Using a single-blade ultrasonic cutting device, a study of ultrasonic cutting of three very different materials is conducted using specimens of cheese, polyurethane foam and epoxy resin. Initial finite element models are created, based on the assumption that the ultrasonic blade causes a crack to propagate in a controlled mode 1 opening, and these are validated against experimental data from three point bend fracture tests and ultrasonic cutting experiments on the materials. Subsequently, the finite element model is developed to represent ultrasonic cutting of a multi-layered material. Materials are chosen whose properties allow a model to be developed that could represent a multi-layer food product or biological structure, to enable ultrasonic cutting systems to be designed for applications both in the field of food processing and surgical procedures. The model incorporates an estimation of the friction condition between the cutting blade and the material to be cut and allows adjustment of the frequency, cutting amplitude and cutting speed.

Journal Article↗

A novel multiple blade ultrasonic cutting device.

In ultrasonic devices consisting of serially coupled tuned components, components whose tuned length dimension is large compared to other dimensions, or components with profiles designed for high gain, the response of the device during operation is often characterised by modal interactions, and especially the excitation of combination resonances. The effects on ultrasonic devices are high noise levels, component failures and poor operating performance. In this paper, energy exchanges between modes are characterised to illustrate the adverse effects of combination resonances. Design solutions are proposed to eliminate these effects which concentrate on reducing the number of modes. In particular, a novel half-wavelength three-blade cutting system tuned to the first longitudinal mode has been designed by finite element modelling. An experimental investigation demonstrates that the measured response does not show evidence of modal interactions.

Journal Article↗

Enhanced vibration performance of ultrasonic block horns.

Block horns are tuned components designed to vibrate in a longitudinal mode at a low ultrasonic frequency. Reliable performance of such horns is normally associated with the amplitude of vibration, uniformity of vibration amplitude at the working surface and the avoidance of modal participation by non-tuned modes at the operating frequency. In order to maximise vibration amplitude uniformity, standard slotting configurations are included in the horn design. However, defining a slotted block geometry which guarantees sufficient tuned frequency isolation from nearby modes as well as high amplitude and amplitude uniformity, is not straightforward. This paper discusses horn configurations which satisfy these criteria and investigates the design requirements of block horns which operate as intermediate components in ultrasonic systems, where the block horn dominates the vibration behaviour of the system. The importance of mode shape characterisation is discussed and modes are classified using experimental data from 3D laser Doppler vibrometer measurements and finite element analysis. In particular, the role of additional fine slots and castellations are studied with reference to two distinct ultrasonic applications involving a similar block horn.

Journal Article↗