Beat-to-beat effects of intraaortic balloon pump timing on left ventricular performance in patients with low ejection fraction.

BACKGROUND: Intraaortic balloon counterpulsation (IABP) timing errors during arrhythmia may result in afterload increases which may negatively influence left ventricular (LV) ejection and LV mechanical dyssynchrony. The aim of our study was to determine beat-to-beat effects of properly timed IABP, premature IAB inflation, and late IAB deflation on LV performance and LV mechanical dyssynchrony in heart failure patients undergoing cardiac surgery. METHODS: In 15 patients, LV pressure-volume relations and LV dyssynchrony were measured by conductance volume catheter. Properly timed IABP was evaluated at a 1:1 assist ratio within a 10 seconds time-span. Premature IAB inflation and late IAB deflation were evaluated at a 1:4 assist ratio. RESULTS: Properly timed 1:1 IABP acutely decreased LV end-systolic volume by 6.1% (p < 0.0001) and LV end-systolic pressure by 17.5% (p < 0.0001) due to decreased aortic impedance. Stroke volume (SV) increased by 14% (p < 0.0001), which correlated markedly with a decrease of LV mechanical dyssynchrony (p < 0.0001). The largest SV increases occurred in patients with lowest contractile state. Premature IAB inflation decreased SV by 20% (p < 0.0001) due to abrupt increase of LV afterload during late ejection. Late IAB deflation increased SV and stroke work by 18% (p < 0.0001) and 16% (p < 0.01) respectively, due to increased afterload during early ejection and decreased afterload during late ejection. CONCLUSIONS: Left ventricular performance during IABP is causally related to changes in LV afterload, and the timing of these changes in relation to contraction or relaxation phases, to LV mechanical dyssynchrony and to contractile state.

Humans↗

Automatic intraaortic balloon pump timing using an intrabeat dicrotic notch prediction algorithm.

PURPOSE: The efficacy of intraaortic balloon counterpulsation (IABP) during arrhythmic episodes is questionable. A novel algorithm for intrabeat prediction of the dicrotic notch was used for real time IABP inflation timing control. DESCRIPTION: A windkessel model algorithm was used to calculate real-time aortic flow from aortic pressure. The dicrotic notch was predicted using a percentage of calculated peak flow. Automatic inflation timing was set at intrabeat predicted dicrotic notch and was combined with automatic IAB deflation. EVALUATION: Prophylactic IABP was applied in 27 patients with low ejection fraction (< 35%) undergoing cardiac surgery. Analysis of IABP at a 1:4 ratio revealed that IAB inflation occurred at a mean of 0.6 +/- 5 ms from the dicrotic notch. In all patients accurate automatic timing at a 1:1 assist ratio was performed. Seventeen patients had episodes of severe arrhythmia, the novel IABP inflation algorithm accurately assisted 318 of 320 arrhythmic beats at a 1:1 ratio. CONCLUSIONS: The novel real-time intrabeat IABP inflation timing algorithm performed accurately in all patients during both regular rhythms and severe arrhythmia, allowing fully automatic intrabeat IABP timing.

Aged↗

Acute decrease of left ventricular mechanical dyssynchrony and improvement of contractile state and energy efficiency after left ventricular restoration.

OBJECTIVE: Surgical left ventricular restoration by means of endoventricular patch aneurysmectomy in patients with postinfarction aneurysm should result in acute improved left ventricular performance by decreasing mechanical dyssynchrony and increasing energy efficiency. METHODS: Nine patients with left ventricular postinfarction aneurysm were studied intraoperatively before and after ventricular restoration with a conductance volume catheter to analyze pressure-volume relationships, energy efficiency, and mechanical dyssynchrony. The end-systolic elastance was used as a load-independent index of contractile state. Left ventricular energy efficiency was calculated from stroke work and total pressure-volume area. Segmental volume changes perpendicular to the long axis were used to calculate mechanical dyssynchrony. Statistical analysis was performed with the paired t test and least-squares linear regression. RESULTS: Endoventricular patch aneurysmectomy reduced end-diastolic volume by 37% (P < .001), with unchanged stroke volume. Systolic function improved, as derived from increased +dP/dt(max), by 42% (P < .03), peak ejection rate by 28% (P < .02), and ejection fraction by 16% (P < .0002). Early diastolic function improved, as shown by reduction of -dP/dt(max) by 34% (P < .006) and shortened tau by 30% (P < .001). Left ventricular end-systolic elastance increased from 1.2 +/- 0.6 to 2.2 +/- 1 mm Hg/mL (P < .001). Left ventricular energy efficiency increased by 36% (P < .002). Left ventricular mechanical dyssynchrony decreased during systole by 33% (P < .001) and during diastole by 20% (P < .005). CONCLUSIONS: Left ventricular restoration induced acute improvements in contractile state, energy efficiency, and relaxation, together with a decrease in left ventricular mechanical dyssynchrony.

Aged↗

Performance of a real-time dicrotic notch detection and prediction algorithm in arrhythmic human aortic pressure signals.

A novel algorithm for real-time detection and prediction of the dicrotic notch from aortic pressure waves was evaluated in arrhythmic aortic pressure signals from heart failure patients. A simplified model of the arterial tree was used to calculate real-time aortic flow from aortic pressure. The dicrotic notch was detected at the first negative dip from the calculated flow, prediction of the notch was performed using a percentage of the decreasing flow. The performance of the real-time dicrotic notch detection algorithm (RTDND) was evaluated during severe arrhythmia from aortic pressure signals of 12 patients. The RTDND was able to detect the dicrotic notch in 98.1%. No false positive dicrotic notch identifications were observed. Prediction of the dicrotic notch was tested at 40%, 20%, and 0% of the decreasing calculated aortic flow. The mean time-delays to the notch were 68 +/- 14 ms, 55 +/- 12 ms, and 43 +/- 8 ms, respectively. Given these small variability, intra-beat prediction of the dicrotic notch may be used for real-time intra-aortic balloon counterpulsation inflation timing.

Aged↗

[Italian translation and prospective validation of fecal incontinence quality of life (FIQL) index].

The evaluation of any functional disease affecting quality of life requires a purpose-designed quality-of-life index for clinical trials as well as for evaluating the outcomes of treatments. The fecal incontinence quality of life index (FIQL) was developed at Minnesota University (USA) for patients with faecal incontinence but could not be used for Italian patients without appropriate cultural and linguistic adaptation. Therefore this index was translated into italian and prospectively validated on a new series of 73 incontinent patients and 8 healthy controls in order to provide Italian coloproctologists with a useful tool for clinical research. The italian version or the FIQL index met all the statistical criteria of reliability, reproducibility, specificity and convergency required and therefore can be used with confidence in clinical trials on such patients.

Adult↗