Pulmonary vein total occlusion following catheter ablation for atrial fibrillation: clinical implications after long-term follow-up.

OBJECTIVES: We present the clinical course and management outcomes of patients with total pulmonary vein occlusion (PVO). BACKGROUND: Pulmonary vein occlusion is a rare complication that can develop after radiofrequency catheter ablation (RFA) of atrial fibrillation (AF). The long term follow-up data of patients diagnosed with PVO are minimal. METHODS: Data from 18 patients with complete occlusion of at least one pulmonary vein (PV) were prospectively collected. All patients underwent RFA for AF using different strategies between September 1999 and May 2004. Pulmonary vein occlusion was diagnosed using computed tomography (CT) and later confirmed by angiography when intervention was warranted. Lung perfusion scans were performed on all patients before and after intervention. The percent stenoses of the veins draining each independent lung were added together to yield an average cumulative stenosis of the vascular cross-sectional area draining the affected lung (cumulative stenosis index [CSI]). RESULTS: The patients' symptoms had a positive correlation with the CSI (r = 0.843, p < 0.05) and a negative one with the lung perfusion (r = -0.667, p < 0.05). A CSI > or =75% correlated well with low lung perfusion (<25%; r = -0.854, p < 0.01). Patients with a CSI > or =75% appeared to improve mostly when early (r = -0.497) and repeat dilation/stenting (r = 0.0765) were performed. CONCLUSIONS: Patients with single PVO are mostly asymptomatic and should undergo routine imaging. On the other hand, patients with concomitant ipsilateral PV stenosis/PVO and a CSI > or =75% require early and, when necessary, repeated pulmonary interventions for restoration of pulmonary flow and prevention of associated lung disease.

Atrial Fibrillation↗

Cardiovascular imaging in the management of atrial fibrillation.

Atrial fibrillation (AF) is he most commonly encountered arrhythmia in clinical practice, with an overall prevalence of 0.4% in the general population. Recent advances in technology and in the understanding of the pathophysiology of AF have led to more definitive and potentially curative therapeutic approaches. Echocardiography has a well-established role in the assessment of cardiac structure and function and risk stratification, and has become an essential part of the guidelines for management of AF. The development of intracardiac echocardiography has led to real-time guidance of percutaneous interventions, including radiofrequency ablation and left atrial appendage closure procedures for patients with AF. Other imaging modalities, including computed tomography and magnetic resonance angiography, have allowed for more accurate measurement and better understanding of the cardiac anatomy. We review the impact of various imaging modalities in the evaluation and management of AF.

Atrial Fibrillation↗

Atrial arrhythmias after surgical maze: findings during catheter ablation.

OBJECTIVES: We describe the clinical and electrophysiologic characteristics and management of post "cut and sew" Maze arrhythmias in symptomatic patients. BACKGROUND: The Cox Maze procedure was developed as a surgical treatment of atrial fibrillation. Until recently, invasive electrophysiologic studies in patients with symptomatic post-operative arrhythmias in this patient population have not been described. METHODS: The management and clinical course of consecutive patients with post-Maze arrhythmias refractory to antiarrhythmic drugs (AADs) between January 2000 and December 2003 are presented. RESULTS: Twenty-three patients (15 men) presented 14 +/- 14 months after Maze surgery for treatment of atrial fibrillation (AF). Eight patients underwent "cut and sew" Maze for lone AF with no other surgical indication. Fifteen patients underwent the "cut and sew" Maze procedure in addition to another surgical procedure: mitral valve surgery (11 patients) and coronary artery bypass graft surgery (4 patients). Eight patients (35%) had recurrent AF secondary to recovered conduction around the lines encircling the pulmonary veins. Five patients were documented to have focal atrial tachycardia, which was mapped to the coronary sinus in 3 patients, to the posterolateral right atrium in 1 patient, and to the left atrial (LA) septum in 1 patient. Four patients had right atrium incisional atrial flutter (AFL), and 6 had LA incisional AFL, which was mapped around the mitral valve annulus in 4 patients and around the right pulmonary veins in 2 patients. Twenty-two of the 23 patients were treated successfully with radiofrequency ablation. At 1-year follow-up, 19 patients were arrhythmia-free and taking no AADs. CONCLUSIONS: After surgical "cut and sew" Maze, approximately one-third of patients experiencing atrial arrhythmias have AF secondary to pulmonary vein-left atrium conduction recovery. Moreover, incisional AFL seems to be a common finding in this group of patients. Catheter-based mapping and ablation of these arrhythmias seems to be feasible and effective.

Aged↗

Effects of cocaine intoxication on the threshold for stun gun induction of ventricular fibrillation.

OBJECTIVES: This study sought to assess cocaine's effects on Taser-induced ventricular fibrillation (VF) threshold in a pig model. BACKGROUND: Stun guns are increasingly used by law enforcement officials to restrain violent subjects, who are frequently intoxicated with cocaine and other drugs of abuse. The interaction of cocaine and the stun gun on VF induction is unknown. METHODS: We tested five adult pigs using a custom device built to deliver multiples of standard neuromuscular incapacitating (NMI) discharge that matched the waveform of a commercially available electrical stun gun (Taser X-26, Taser International, Scottsdale, Arizona). The NMI discharges were applied in a step-up and step-down fashion at 5 body locations. End points included determination of maximum safe multiple, minimum VF-inducing multiple, and ventricular fibrillation threshold (VFT) before and after cocaine infusion. RESULTS: Standard NMI discharges (x1) did not cause VF at any of the 5 locations before or after cocaine infusion. The maximum safe multiple, minimum VF-inducing multiple, and VFT of NMI application increased with increasing electrode distance from the heart. There was a 1.5- to 2-fold increase in these values at each position after cocaine infusion, suggesting decreased cardiac vulnerability for VF. Cocaine increased the required strength of NMI discharge that caused 2:1 or 3:1 ventricular capture ratios at all of the positions. No significant changes in creatine kinase-MB and troponin-I were seen. CONCLUSIONS: Cocaine increased the VFT of NMI discharges at all dart locations tested and reduced cardiac vulnerability to VF. The application of cocaine increased the safety margin by 50% to 100% above the baseline safety margin.

Animals↗

Novel robotic catheter remote control system: feasibility and safety of transseptal puncture and endocardial catheter navigation.

OBJECTIVES: The aims of this study were to demonstrate the safety and the feasibility of the robotic catheter remote control system (CCS) in endocardial navigation in all cardiac chambers, as well as facilitation of the transseptal puncture. BACKGROUND: CCS has been developed to facilitate control and precise positioning of catheters within the cardiovascular system. METHODS: CCS consists of a remote catheter manipulator, a set up joint, a physician workstation, and a steerable guide catheter (SGC) and sheath. A conventional 4-mm tip catheter was inserted through the SGC to perform mapping of five predefined targets in each cardiac chamber. Seven mongrel dogs were used in this study. Intracardiac echocardiography and three-dimensional (3-D) electroanatomical mapping were integrated with CCS to facilitate catheter manipulation and to guide transseptal puncture. The time to complete the transseptal puncture and the time to complete access to the predefined targets in each cardiac chamber were measured. Gross and microscopic examinations of the accessed and ablation sites were performed to evaluate safety. RESULTS: Transseptal puncture was performed successfully in all animals with a mean time of 7 +/- 3 minutes. Procedure times to access the five targets in the right atrium, right ventricle, left atrium, and left ventricle were 5.6 +/- 1.7, 4.6 +/- 1.5, 13.5 +/- 11.0, 7.0 +/- 2.9 minutes, respectively. There were no intracardiac damages associated with catheter manipulation noted in the excised hearts. CONCLUSIONS: Endocardial catheter navigation and mapping using the robotic catheter remote control is safe and feasible. Moreover, the CCS could be used to perform transseptal puncture and left atrial instrumentation.

Animals↗

Remote magnetic navigation to map and ablate left coronary cusp ventricular tachycardia.

BACKGROUND: Premature ventricular contractions (PVCs) and ventricular tachycardia may arise from the coronary cusps. Navigation, mapping, and ablation in the coronary cusps can be challenging. Remote magnetic navigation may offer an alternative to conventional manually operated catheters. OBJECTIVE: We report a case of left coronary cusp ventricular tachycardia ablation using remote magnetic navigation. METHODS: Right ventricular outflow tract and coronary cusp mapping, and ablation of the left coronary cusp using a remote magnetic navigation and three-dimensional (3-D) mapping system was performed in a 28-year-old male with frequent, symptomatic PVCs and ventricular tachycardia. RESULTS: Successful ablation of left coronary cusp ventricular tachycardia was performed using remote magnetic navigation. CONCLUSIONS: Remote magnetic navigation may be used to map and ablate PVCs and ventricular tachycardia originating from the coronary cusps.

Adult↗

Phrenic nerve injury after catheter ablation: should we worry about this complication?

INTRODUCTION: Phrenic nerve injury (PNI) is a complication that can occur with catheter ablation. METHODS: Data from 17 patients with PNI following different catheter ablation techniques were reviewed. PNI was defined as decreased motility (transient) or paralysis (persistent) of the hemi-diaphragm on fluoroscopy or chest X-ray. Patient's recovery was monitored. Normalization of chest images and sniff test would be considered as complete clinical recovery. RESULTS: Out of the 17 PNI patients (16 right, 1 left), 13 (11 persistent, 2 transient) occurred after pulmonary veins isolation with or without superior vena cava ablation. Three patients had persistent PNI after sinus node modification and one other patient experienced PNI after epicardial ventricular tachycardia ablation. Ablation was performed with different energy source including radiofrequency (n = 13), cryothermal (n = 1), ultrasound (n = 2) and laser (n = 1). Patient's symptoms varied broadly from asymptomatic to dyspnea, and even to respiratory insufficiency that required temporary mechanical ventilation support. Two patients with transient PNI resolved immediately after the procedure and the other 15 persistent PNI patients resolved within a mean time of 8.3 +/- 6.6 months. CONCLUSIONS: PNI caused by catheter ablation appears to functionally recover over time regardless of the energy sources used for the procedure.

Adult↗

Left superior vena cava isolation in patients undergoing pulmonary vein antrum isolation: impact on atrial fibrillation recurrence.

BACKGROUND: A persistent left superior vena cava (SVC) can be an arrhythmogenic source in patients with atrial fibrillation (AF) through connections from the coronary sinus (CS) and the left atrium (LA). The left SVC can be electrically isolated. However, little clinical data about the impact of left SVC disconnection on AF outcome are available. We report on six patients with left SVC and recurrent AF. OBJECTIVES: The purpose of this study was to assess the impact of left SVC isolation on AF recurrence. METHODS: Six patients (4 men and 2 women; age 50 +/- 6.4 years) with symptomatic drug-refractory AF and persistent left SVC presented to our laboratory for treatment. Four of the patients had left SVC isolation only because there was no conduction recovery in the pulmonary veins (PVs) after several previous procedures. RESULTS: Conduction between the left SVC and the CS and LA was documented, as was spontaneous ectopies in three patients that degenerated into AF in one patient. Isolation of the left SVC was successful in all patients. Isolation was relatively easy to perform (10.25 +/- 1.6 minutes), with no complications. After follow-up of 13 +/- 7.4 months, all patients were in sinus rhythm and free from AF without antiarrhythmic drugs. CONCLUSION: This study stresses the importance of looking for unusual sources of AF in patients presenting for repeat procedures or in those in whom the PVs have been ruled out as a source triggering AF. We present clinical evidence that in patients with AF and left SVC, isolation of the PVs only may not be sufficient to suppress AF. Thus, diagnosis and isolation of the left SVC appears critical to preventing AF recurrence in patients with AF when ablation is considered.

Atrial Fibrillation↗

Brief communication: atrial-esophageal fistulas after radiofrequency ablation.

BACKGROUND: Ablation of atrial fibrillation is generally considered safe and effective. However, atrial-esophageal fistulas have recently been reported as a rare but fatal complication. OBJECTIVE: To describe 9 patients with atrial-esophageal fistulas after ablation for atrial fibrillation. DESIGN: Retrospective case series. SETTING: Institutions where cardiologists performed atrial fibrillation ablation procedures. PATIENTS: 9 patients with atrial-esophageal fistulas after atrial fibrillation ablation. MEASUREMENTS: Demographic characteristics, mortality, presenting signs and symptoms, and days to presentation. RESULTS: Patients presented a mean of 12.3 days (range, 10 to 16 days) after their procedures. Nonspecific symptoms included fever, leukocytosis, and neurologic abnormalities. All patients died. Only 4 patients received correct diagnoses before death, although all patients presented to a physician. In 3 patients, surgical repair was attempted. LIMITATIONS: Few physicians reported cases, and only approximate numbers of procedures performed by the physicians are known. Thus, the authors could not estimate the incidence of atrial-esophageal fistulas after ablation. CONCLUSIONS: Formation of atrial-esophageal fistulas is a rare but potentially devastating complication of atrial fibrillation ablation. This disorder may have an indolent presentation and may mimic other disease states, such as stroke or sepsis.

Atrial Fibrillation↗

Vagal denervation and atrial fibrillation inducibility: epicardial fat pad ablation does not have long-term effects.

BACKGROUND: Major epicardial fat pads contain cardiac ganglionated plexi of the autonomic, predominantly vagal nerves. Vagal denervation may improve the success rate of atrial fibrillation (AF) treatment. OBJECTIVES: The purpose of this study was to elucidate the long-term effects of fat pad ablation on the electrophysiologic characteristics of the atrium and AF inducibility. METHODS: Six mongrel dogs were studied. Cervical vagal stimulation was applied to determine effects on the sinus node, AV node, atrial effective refractory period (AERP), and AF inducibility. AERP and AF inducibility were evaluated at both the right atrial and left atrial appendages and at the right atrial and left atrial free walls. Radiofrequency energy was delivered epicardially to the entire areas of two major fat pads: right pulmonary vein fat pad and inferior vena cava-left atrium fat pad. Cervical vagal stimulation then was applied to confirm the acute effects of fat pad ablation. The same evaluation was repeated 4 weeks later. RESULTS: The effects of vagal stimulation on the sinus node, AV node, and AERP were significantly eliminated immediately after fat pad ablation. However, these denervation effects disappeared after 4 weeks. At baseline, AF inducibility was increased by vagal stimulation (right atrial appendage: 72% +/- 31% vs 4.8% +/- 12%; right atrial free wall: 75% +/- 31% vs 0.0% +/- 0.0%; left atrial appendage: 60% +/- 29% vs 0.0% +/- 0.0%; left atrial free wall: 65% +/- 42% vs 0.0% +/- 0.0%). Fat pad ablation significantly reduced this vagal stimulation effect (8.3% +/- 20%, 10% +/- 22%, 17% +/- 29%, and 25% +/- 29%, respectively). However, similar to baseline, AF inducibility was strongly augmented by vagal stimulation 4 weeks after fat pad ablation (96% +/- 10%, 100% +/- 0.0%, 100% +/- 0.0%, and 95% +/- 11%, respectively). CONCLUSION: Radiofrequency fat pad ablation may not achieve long-term suppression of AF induction in this canine model.

Adipose Tissue↗

Surgery for paroxysmal atrial fibrillation in the setting of mitral valve disease: a role for pulmonary vein isolation?

BACKGROUND: It is unknown whether pulmonary vein isolation or a complete Cox-Maze procedure is needed to ablate paroxysmal atrial fibrillation in patients with mitral valve disease. Our objective was to assess the impact of different surgical treatments for this arrhythmia in patients undergoing mitral valve surgery. METHODS: From July 1993 to January 2004, 152 patients underwent combined surgical treatment of paroxysmal atrial fibrillation and mitral valve disease. Ablation procedures included pulmonary vein isolation alone (n = 31, 20%), pulmonary vein isolation with left atrial connecting lesions (n = 80, 53%), and Cox-Maze (n = 41, 27%). The latter had longer durations of atrial fibrillation than the former (p < 0.0001). Rhythm documented on 1,225 postoperative electrocardiograms was used to estimate prevalence of, and risk factors for, atrial fibrillation across time. Ablation failure was defined as occurrence of atrial fibrillation any time beyond 6 months after operation. RESULTS: Prevalence of postoperative atrial fibrillation peaked at 22% at 2 weeks and declined to 9% at 1 year. Risk factors included older age (p = 0.09), larger left atrium (p = 0.05), and rheumatic (p = 0.003) and degenerative etiologies (p = 0.03). Freedom from ablation failure was 84% at one year. Ablation procedure did not affect prevalence of atrial fibrillation or incidence of ablation failure. CONCLUSIONS: Pulmonary vein isolation alone may be adequate treatment for patients with paroxysmal atrial fibrillation undergoing mitral valve surgery, particularly when it is of short duration. A randomized trial is necessary to examine this strategy, especially in patients with longer duration of paroxysmal atrial fibrillation.

Aged↗

Surgery for permanent atrial fibrillation: impact of patient factors and lesion set.

BACKGROUND: Whether a complete Cox-maze procedure is needed to ablate permanent atrial fibrillation in patients undergoing concomitant cardiac surgery is unknown. Our objective was to assess the effectiveness of different lesion sets in such patients. METHODS: From November 1991 to January 2004, 575 patients underwent surgical treatment of permanent atrial fibrillation (duration > 6 months); mitral valve disease was the primary indication for surgery in 74%. Procedures included pulmonary vein isolation alone (n = 68, 12%), pulmonary vein isolation with left atrial connecting lesions (n = 265, 46%), and Cox-maze (n = 242, 42%). Rhythm documented on 5,120 postoperative electrocardiograms was used to estimate time-related prevalence of, and risk factors for, atrial fibrillation. RESULTS: Prevalence of postoperative atrial fibrillation peaked at 46% two weeks after operation, declining to 24% at one year. Patient-related risk factors for increased prevalence included older age (p < 0.0001), larger left atrium (p < 0.0001), and longer duration of preoperative atrial fibrillation (p = 0.0008). The Cox-maze procedure and lesion sets resembling it created with alternative energy sources had a similarly low prevalence of late postoperative atrial fibrillation; in contrast, pulmonary vein isolation and lesion sets that did not include a lesion to the mitral anulus were less effective. CONCLUSIONS: This study suggests that in cardiac surgical patients with permanent atrial fibrillation the left atrial lesion set should include wide pulmonary vein isolation, at least one connection between right and left pulmonary veins, and a connection to the mitral anulus. Availability of alternative energy sources to create lesions sets has virtually eliminated the need for the cut-and-sew Cox-maze procedure.

Adult↗

Endoscopic fiberoptic assessment of balloon occlusion of the pulmonary vein ostium in humans: comparison with phased-array intracardiac echocardiography.

BACKGROUND: Anatomic pulmonary vein (PV) variants may affect the ability to position balloon catheter systems at the left atrium (LA)-PV junction with complete circumferential contact, resulting in ineffective PV isolation. OBJECTIVES: This feasibility study was performed to assess the use of the fiberoptic endoscopic light ring balloon catheter (ELRBC) in accessing the PVs and achieving adequate contact at the LA-PV junction, as visualized by phased-array intracardiac echocardiography (ICE). METHODS: We enrolled five men (mean age 59 +/- 8 years) with drug-refractory atrial fibrillation. The ELRBC consisted of a 25-mm balloon catheter with an integral endoscope contained within the balloon and a custom deflectable sheath. At the end of conventional PV isolation, the ELRBC was inserted into the LA in an attempt to position the balloon at each PV ostium. The real position of the ELRBC at this level was assessed by ICE in all patients. RESULTS: All but two PVs (right inferior PVs) (89%) were accessed with the ELRBC in a mean time of 17 +/- 3 minutes, and complete circumferential contact was visualized with the fiberoptic endoscopic component in 15 of 16 PVs accessed (94%). Contact was also confirmed by the absence of color Doppler flow through the balloon-occluded PV, as seen on ICE. On two occasions a gap was seen with the fiberoptic endoscope and visualized by the ICE only after optimization of the echo window. No complications were observed. CONCLUSIONS: The ELRBC is able to access the PV without complications. The endoscope and ICE were complementary for positioning of the balloon at the LA-PV junction and for the definition of circumferential contact.

Aged↗

Efficacy of catheter ablation of atrial fibrillation in patients with hypertrophic obstructive cardiomyopathy.

BACKGROUND: Although pulmonary vein (PV) antrum isolation is effective in curing atrial fibrillation (AF) in a variety of heart diseases, results in patients with hypertrophic obstructive cardiomyopathy (HOCM) have not been reported. OBJECTIVES: The purpose of this study was to report the results and outcome of PV antrum isolation in patients with AF and HOCM. METHODS: Data from patients with AF and HOCM who underwent PV antrum isolation between February 2002 and May 2004 were analyzed retrospectively. An intracardiac echocardiographic-guided ablation technique with an 8-mm-tip catheter was used in all patients. Patients were followed in the outpatient clinic at 3, 6, and 12 months after ablation. RESULTS: Twenty-seven patients with AF and HOCM (mean age 55 +/- 10 years) underwent PV antrum isolation. Mean AF duration was 5.4 +/- 3.6 years. AF was paroxysmal in 14 (52%), persistent in 9 (33%), and permanent in 4 (15%). During a mean follow-up of 341 +/- 237 days, 13 patients (48%) had AF recurrence. Of these patients, five maintained sinus rhythm (SR) with antiarrhythmic drugs, one patient remained in persistent AF, and seven patients underwent a second PV antrum isolation. After the second PV antrum isolation, five patients remained in SR, giving a final success rate of 70% (19/27). Two patients had recurrence after second PV antrum isolation; one maintained SR with antiarrhythmic drugs and one remained in persistent AF. CONCLUSION: Compared with previously reported results in patients with lone AF, AF recurrence after the first PV antrum isolation is higher in patients with HOCM. However, after repeated ablation procedures, long-term cure can be achieved in a sizable number of patients. PV antrum isolation is a feasible therapeutic option in patients with AF and HOCM.

Atrial Fibrillation↗

Avoiding microbubbles formation during radiofrequency left atrial ablation versus continuous microbubbles formation and standard radiofrequency ablation protocols: comparison of energy profiles and chronic lesion characteristics.

BACKGROUND: Radiofrequency (RF) energy parameters and chronic lesion characteristics associated with the microbubbles formation have not been yet fully elucidated. OBJECTIVES: The objective of this study was to compare the energy profiles and chronic lesion characteristics associated with RF ablation of the pulmonary vein antrum using three different ablation protocols: (1) avoiding microbubbles; (2) continuous microbubble formation; (3) temperature-guided ablation. METHODS: A 4-mm tip ablation catheter was used for creating RF ablation lesions in 15 adult mongrel dogs. All ablation lesions were created at the posterior aspect of the PV antrum in each animal. Avoiding microbubbles (group 1, n = 5 dogs, 23 lesions), continuous microbubble formation (group 2, n = 5 dogs, 22 lesions), and temperature-guided (group 3, n = 5 dogs, 19 lesions, target temperature 60 degrees C/power limit 50 W) ablation lesions were analyzed. RESULTS: Group 1 showed significantly lower power (19 +/- 8.6 W), lower temperature (50 +/- 4.8 degrees C), higher efficiency-of-heating index (2.9 +/- 0.8 degrees C/W), and lower impedance (109 +/- 24.4 Omega) than groups 2 (38 +/- 8.4 W; 63 +/- 10 degrees C; 1.8 +/- 0.8 degrees C/W; 148 +/- 34.4 Omega) and 3 (44 +/- 12 W; 57 +/- 2.4 degrees C; 1.4 +/- 0.5 degrees C/W; 139 +/- 23.1 Omega) (P < 0.001 vs groups 2 and 3). During ablation, no significant events were detected in group 1, but 11 cases of audible pop, 11 cases of catheter tip charring, and 1 case of fatal myocardial perforation were observed in groups 2 and 3. Transmural lesions were more frequently created in group 1. CONCLUSION: RF energy delivery applying "avoiding microbubbles" protocol seems to be associated with higher degree of safety and efficacy when compared to temperature-guided and continuous microbubble-formation ablation protocols.

Animals↗

Catheter ablation of ventricular fibrillation storm in patients with infiltrative amyloidosis of the heart.

Recent studies have demonstrated that premature ventricular contractions (PVCs) originating from the Purkinje system are responsible for initiation of ventricular fibrillation (VF) in patients with and without structural heart disease. Ablation of the PVCs has been shown to be feasible. We report 2 patients with repetitive VF associated with cardiac amyloidosis. Each episode of ventricular arrhythmia was preceded by monomorphic PVC. The electrical storms were drug resistant. Electrophysiological testing was performed and the sites of earliest activation were localized within the left ventricle in the absence of significant scar tissue. After ablation, PVCs subsided and there were no further VF recurrences.

Amyloidosis↗