PubMed Health⌕ Search

Biomedical subjects

Andrea Somogyi

Publications and source records attributed to Andrea Somogyi.

7 recordsLinked to original sources

Three-dimensional trace element analysis by confocal X-ray microfluorescence imaging.

A three-dimensional (3D) variant of scanning micro X-ray fluorescence (XRF) is described and evaluated at the ID18F instrument of the European Synchrotron Radiation Facility (ESRF). The method is based on confocal excitation/detection using a polycapillary half-lens in front of the energy-dispersive detector. The experimental arrangement represents a significant generalization of regular two-dimensional (2D) scanning micro-XRF and employs a detector half-lens whose focus coincides with that of the focused incoming beam. The detection volume defined by the intersection of the exciting beam and the energy-dependent acceptance of the polycapillary optics is 100-350 mum(3). Minimum detection limits are sub-ppm, and sensitivities are comparable with regular scanning XRF. Next to the reduction of in-sample single/multiple scattering, the setup provides the possibility of sample depth scans with an energy-dependent resolution of 10-35 mum in the energy range of 3-23 keV and the possibility of performing 3D-XRF analysis by simple XYZ linear scanning. This provides a suitable alternative to X-ray fluorescence tomography. The method is illustrated with results of the analysis of solid inclusions in diamond and fluid inclusions in quartz.

Journal Article↗

Focusing X-rays with simple arrays of prism-like structures.

This report discusses the optimization strategy, the theoretical background and first experimental data of a new refractive lens for focusing X-rays. In order to reduce the absorption of X-rays in this transmission lens, optically passive material was removed from the necessarily concave lens shape in a highly regular pattern. The feature dimensions require lens production and replication by deep X-ray lithography, which allows shaping in only one dimension. Consequently such a lens can focus in one direction only, so a crossed lens pair is needed for two-dimensional focusing. The single lens is composed of two large prisms of millimetre size, which touch each other at one of the tips, like an old sand clock. Each large prism contains a highly regular structure of essentially identical prism-like smaller segments. The first lens prototypes focused an X-ray beam with a vertical size of 500 microm and a photon energy of 8 keV to a line with a width of only 2.8 microm. This is only slightly worse than the line width of 1.73 microm expected for its focal length of f = 2.18 m. The photon density enhancement in the focus was 25, but could have been larger as the lens can intercept a beam height of 2.6 mm.

Journal Article↗

X-ray fluorescence tomography of individual municipal solid waste and biomass fly ash particles.

Information about Cd distribution inside single municipal solid waste and biomass fly ash particles is fundamental since it affects its leachability. The internal 2D distributions of the main and trace elements in such highly inhomogeneous matrixes were successfully determined by means of the combined synchrotron radiation induced micro X-ray fluorescence (micro-SRXRF) and tomography (micro-SRXRFT) techniques. Scanning micro-SRXRF measurements show Cd elemental distribution within single fly ash particles to be inhomogeneous, but no information can be obtained about its internal distribution. During micro-SRXRFT analysis, single fly ash particles are successively measured by a rotational-translational scan in a VH=2 x 5 microm2 microbeam. The 2D internal elemental distribution images, obtained by the modified simultaneous algebraic reconstruction technique algorithm, provide the size and the location of Cd-containing areas together with the location of other measurable elements. Results showed Cd concentration to be higher in the core of the fly ash particles analyzed rather than on the surface of the particles. Moreover, in both ashes, Ca-containing matrixes are found to be the main Cd-bearing phases. A possible mechanism for Cd adsorption on the fly ash particles is proposed based on the obtained results.

Cadmium↗

Microextended X-ray absorption fine structure studies of cadmium speciation within single municipal solid waste fly ash particles.

The local chemical structure of trace amounts of cadmium within microvolumes of highly inhomogeneous municipal solid waste fly ash particles was successfully monitored by means of micro-EXAFS. A new quantification procedure was developed for the evaluation of the micro-EXAFS data sets obtained from each individual particle based on a reverse Monte Carlo simulation. Evidence has been presented for the existence of cadmium silicate and cadmium chloride, with the cadmium silicate being the dominant form, and it has been demonstrated that the cadmium exists in both crystalline and amorphous states within the microspots analyzed.

Absorption↗

Microchemical element imaging of yeast and human cells using synchrotron X-ray microprobe with Kirkpatrick-Baez optics.

Trace element imaging and speciation analysis in cells and subcellular compartments is a challenging and important objective for modern analytical chemistry in order to better understand the biological chemistry of essential and toxic elements. A focusing system based on Kirkpatrick-Baez design optics mounted on a synchrotron radiation scanning X-ray microscope has been developed at the ESRF and was used for trace element quantitative imaging in single cells. The focused microbeam (1.3 x 3.2 microm(2)) obtained in that way led to a photon flux as bright as 1.5 x 10(11) photons/s at 14 keV. The absolute detection limit of this analytical probe, as measured on standard reference materials, was shown to be 2 x 10(-)(17) g for most elements. Chemical maps of human carcinoma and of Saccharomyces cerevisiae cells were obtained for minor (P, S, Cl, K) and trace elements (Fe, Zn). Within human cancer cells, chemical elements are homogeneously distributed at the current spatial resolution and correlated with the sample's mass, except Fe, which shows micrometer-sized structures around the cell nucleus, and Zn, which slightly concentrates in the nucleus, while chemical maps of S. cerevisiae show homogeneous pattern distribution at the cellular level.

Cell Line, Tumor↗

A Monte Carlo model for studying the microheterogeneity of trace elements in reference materials by means of synchrotron microscopic X-ray fluorescence.

Synchrotron micro-XRF, a trace-level microanalytical method, allows quantitative study of the nature and degree of heterogeneity of inorganic trace constituents in solid materials with a homogeneous matrix. In this work, the standard reference materials NIST SRM 613, Trace Elements in 1 mm Glass Wafers, and NIST SRM 1577a, Trace Elements in Bovine Liver, are examined at the 10100-ng mass level using X-ray beams of 5-150 microm in diameter. A procedure based on a large number of repeated analyses of small absolute amounts of the SRMs allows calculation of the minimal representative mass of the standard. The microheterogeneity of both NIST SRM 613 and NIST SRM 1577a was investigated with the aim of evaluating their suitability as reference materials for trace-level microanalytical techniques. A Monte Carlo simulation model was constructed for both homogeneous and heterogeneous materials to elucidate the dependence of the calculated minimal representative mass on the total analyzed mass in the case of materials that showstrongly heterogeneous features at the microscopic level.

Journal Article↗

Direct determination of cadmium speciation in municipal solid waste fly ashes by synchrotron radiation induced mu-X-ray fluorescence and mu-X-ray absorption spectroscopy.

Cadmium is a toxic metal that causes environmental concern in connection with utilization and land filling of ash from combustion of municipal solid waste (MSW). Collecting information about the chemical associations of Cd in ash is fundamental since this affects its solubility and leachability from the ash material. In the work presented here, the content, distribution, and chemical forms of toxic metals especially of Cd on/in individual Municipal Solid Waste (MSW) fly ash particles have been investigated in situ by synchrotron radiation induced mu-X-ray fluorescence and absorption spectrometry. The use of an excitation energy of 27 keV made it possible to detect trace metals, such as Cd, present at ppm levels routinely. Changing the excitation energy in the vicinity of the absorption edge of Cd (26.71 keV), the absorption spectra of this element were measured for the first time in this high energy range in micron-sized spots of individual fly ash particles. The measurements indicated Cd to be preferably concentrated in some small areas ("hot-spots") with high concentration (up to 200 ppm) rather than in a homogeneous distribution or as a thin coating on the whole particle surface, making the surface-reaction the most probable mechanism of Cd enrichment during MSW combustion processes. Comparisons of XAS spectra of fly ashes and reference compounds showed that in the particles studied Cd is present in the oxidation state +2. Analyses of linear combinations of standard spectra allowed estimating the Cd presence within fly ash particles as an admixture of primarily CdSO4, CdO, and CdCl2 as well as an unidentified compound not included as a standard.

Air Pollutants↗