PubMed Health⌕ Search

Biomedical subjects

Andreas Dahlin

Publications and source records attributed to Andreas Dahlin.

3 recordsLinked to original sources

On-line coupling of a microelectrode array equipped poly(dimethylsiloxane) microchip with an integrated graphite electrospray emitter for electrospray ionisation mass spectrometry.

A novel method for the manufacturing of microchips for on-chip combinations of electrochemistry (EC) and sheathless electrospray ionisation mass spectrometry (ESI-MS) is described. The technique, which does not require access to clean-room facilities, is based on the incorporation of an array of gold microcoil electrodes into a poly(dimethylsiloxane)(PDMS) microflow channel equipped with an integrated graphite based sheathless ESI emitter. Electrochemical measurements, which were employed to determine the electroactive area of the electrodes and to test the microchips, show that the manufacturing process was reproducible and that the important interelectrode distance in the electrochemical cell could to be adequately controlled. The EC-ESI-MS device was evaluated based on the ESI-MS detection of the oxidation products of dopamine. The results demonstrate that the present on-chip approach enables full potentiostatic control of the electrochemical cell and the attainment of very short transfer times between the electrochemical cell and the electrospray emitter. The transfer times were 0.6 and 1.2 s for flow rates of 1.0 and 0.5 microL min(-1), respectively, while the electrochemical conversion efficiency of the electrochemical cell was found to be 30% at a flow rate of 0.5 microL min(-1). To decouple the electrochemical cell from the ESI-MS high voltage and to increase the user-friendliness, the on-line electrochemistry-ESI-MS experiments were performed using a wireless Bluetooth battery-powered instrument with the chip floating at the potential induced by the ESI high voltage. The described on-chip EC-ESI-MS device can be used for fundamental electrochemical investigations as well as for applications based on the use of electrochemically controlled sample pretreatment, preconcentration and ionisation steps prior to ESI-MS.

Dimethylpolysiloxanes↗

Localized surface plasmon resonance sensing of lipid-membrane-mediated biorecognition events.

Supported phospholipid bilayers (SPBs) have emerged as important model systems for studies of the natural cell membrane and its components, which are essential for the integrity and function of cells in all living organisms, and also constitute common targets for therapeutic drugs and in disease diagnosis. However, the preferential occurrence of spontaneous SPB formation on silicon-based substrates, but not on bare noble-metal surfaces, has so far excluded the use of the localized surface plasmon resonance (LSPR) sensing principle for studies of lipid-membrane-mediated biorecognition reactions. This is because the LSPR phenomenon is associated with, and strongly confined to, the interfacial region of nanometric noble-metal particles. This problem has been overcome in this study by a self-assembly process utilizing localized rupture of phospholipid vesicles on silicon dioxide in the bottom of nanometric holes in a thin gold film. The hole-induced localization of the LSPR field to the voids of the holes is demonstrated to provide an extension of the LSPR sensing concept to studies of reactions confined exclusively to SPB-patches supported on SiO2. In particular, we emphasize the possibility of performing label-free studies of lipid-membrane-mediated reaction kinetics, including the compatibility of the assay with array-based reading (approximately 7 x 7 microm2) and detection of signals originating from bound protein in the zeptomole regime.

Adsorption↗

Plasmonic sensing characteristics of single nanometric holes.

The optical response of isolated holes in 20 nm thin gold is probed as a function of alkanethiol CH(3)(CH2)x SH (x epsilon in 1-15) and protein adsorption using dark-field spectroscopy. We establish that the plasmon excitations of single and short-range ordered 60 nm holes exhibit similar E-field decay lengths delta approximately 10-20 nm and that a single hole can be used to resolve the successive adsorption of a protein (biotin-BSA) and its interaction partner (neutravidin). The data confirm the localized character of the hole plasmon and demonstrate that its applicability for bio/chemosensing is similar to that of particle plasmons.

Journal Article↗