Effects of zero-filling and apodization on spectral integrals in discrete Fourier-transform spectroscopy of noisy data.

The influence of noise on the standard deviation of spectral integrals is examined. Calculations assuming discrete Fourier-transform data are compared with Monte-Carlo simulations. The effects of zero-filling and apodization are examined for free-induction-decay (FID) signals and for symmetric spin-echo signals in one and two dimensions, with particular attention to features not previously presented in the literature. Findings suggest that for mild apodization, the known sensitivity enhancement due to zero-filling in either the real or the imaginary part signal [E. Bartholdi, R.R. Ernst, Fourier spectroscopy and the causality principle, J. Magn. Reson., 11 (1973) 9-19] is maintained; however, for stronger apodization filters, this enhancement can be obliterated completely. It is shown that results obtained by analysis of one-dimensional signals can be readily applied to multi-dimensional data. Furthermore, zero-filling has a negligible effect for symmetric spin-echo signals with implications for signal averaging in magnetic resonance imaging and spectroscopic imaging.

Journal Article↗

Detection and correction of frequency instabilities for volumetric 1H echo-planar spectroscopic imaging.

Spectral quality in 1H magnetic resonance spectroscopic imaging (MRSI) critically depends on the stability of the main magnetic field. For echo-planar MRSI implemented at 3 T, temperature variation in the passive steel shims of the magnet system can lead to a significant drift in the resonance frequency. A method is presented that incorporates interleaved measurement of the instantaneous resonance frequency of a reference water signal into a volumetric MRSI sequence and allows correction for the drift during postprocessing. Results from normal human brain at 3 T indicate that the correction largely removes lineshape distortions, recovers metabolite signal loss, and improves spectral quality by reducing the width of spectral lines; however, particularly in inferior regions, other sources of distortion may be present that cause broadening of spectral lines.

Algorithms↗

Achieving sufficient spectral bandwidth for volumetric 1H echo-planar spectroscopic imaging at 4 Tesla.

Complete coverage of the in vivo proton metabolite spectrum, including downfield resonances, requires a spectral bandwidth of approximately 9 ppm. Spectral bandwidth of in vivo echo-planar spectroscopic imaging (EPSI) is primarily limited by gradient strength of the oscillating readout gradient, gradient slew rate, and limits on peripheral nerve stimulation for human subjects. Furthermore, conventional EPSI reconstruction, which utilizes even and odd readout echoes separately, makes use of only half the spectral bandwidth. In order to regain full spectral bandwidth in EPSI, it has previously been suggested to apply an interlaced Fourier transform (iFT), which uses even and odd echoes simultaneously. However, this method has not been thoroughly analyzed regarding its usefulness for in vivo 3D EPSI. In this Note, limitations of the iFT method are discussed and an alternative, cyclic spectral unwrapping, is proposed, which is based on prior knowledge of typical in vivo spectral patterns.

Adult↗

Sensitive and fast T1 mapping based on two inversion recovery images and a reference image.

We developed a fast method to obtain T1 relaxation maps in magnetic resonance imaging (MRI) based on two inversion recovery acquisitions and a reference acquisition, while maintaining high sensitivity by utilizing the full dynamic range of the MRI signal. Optimal inversion times for estimating T1 in the human brain were predicted using standard error propagation theory. In vivo measurements on nine healthy volunteers yielded T1 values of 1094+/-18 ms in gray matter and 746+/-40 ms in white matter, in reasonable agreement with literature values using conventional approaches. The proposed method should be useful for clinical studies because the T1 maps can be obtained within a few seconds.

Algorithms↗

Volumetric proton spectroscopic imaging of mild traumatic brain injury.

BACKGROUND AND PURPOSE: Poor clinical outcomes without notable neuroimaging findings after mild traumatic brain injury (MTBI) suggest diffuse tissue damage and altered metabolism not observable with conventional MR imaging and CT. In this study, MTBI-associated metabolic changes were assessed over the entire brain by using volumetric proton MR spectroscopic imaging (MRSI) and the findings related to injury and outcome assessments. METHODS: Fourteen subjects with mild closed head injury (Glasgow Coma Scale [GCS] scores of 13-15) underwent structural MR imaging and proton MRSI at 1.5 T within 1 month of injury. Distributions of N-acetylaspartate (NAA), total creatine (Cr), and total choline (Cho) were mapped over a wide region of the brain, and metabolite ratios were calculated for 25 regions without MR imaging abnormalities. Results were compared with data from 13 control subjects. RESULTS: Significant changes (P <.05) were found for some, but not all, brain regions for the average values from all MTBI subjects, with reduced NAA/Cr, increased Cho/Cr, and reduced NAA/Cho. Global NAA/Cho obtained from the sum of all sampled regions in two subjects was significantly reduced. Metabolite ratios were not significantly correlated with GCS score at admission or Glasgow Outcome Scale (GOS) score at 6 months after injury, although they were weakly correlated with GOS score at discharge. CONCLUSION: These results show evidence of widespread metabolic changes following MTBI in regions that appear normal on diagnostic MR images. Although the association with injury assessment and outcome is weak, this preliminary study demonstrates the applicability of volumetric proton MRSI for evaluating diffuse injury associated with MTBI.

Adolescent↗

Comparison of inversion recovery preparation schemes for lipid suppression in 1H MRSI of human brain.

To reduce contamination from subcutaneous lipid regions in MR spectroscopic imaging (MRSI) of whole brain, lipid signals are often suppressed using T(1) nulling methods. If a range of lipid T(1) values is present, the suppression efficiency will be improved using multiple inversion recovery (MIR) preparation. This study compared single IR (SIR) and double IR (DIR) applied with a volumetric MRSI sequence at 1.5 T based on experimental measurement of lipid T(1) and T(2) relaxation rates. At short and medium echo times (TEs), an approximately 28-47% improvement in lipid suppression was achieved with DIR compared to SIR. However, it also led to a loss of 37-43% in signal-to-noise ratio (SNR) for metabolites. Thus, SIR appears to be the better choice for suppressing lipid signals and maintaining metabolite sensitivity.

Aspartic Acid↗

Improved spectral quality for 3D MR spectroscopic imaging using a high spatial resolution acquisition strategy.

Spectral quality in (1)H MR spectroscopic imaging (MRSI) of the brain is often significantly degraded in regions subject to local magnetic susceptibility variations, which results in broadened and distorted spectral lineshapes. In this report, a modified acquisition strategy for volumetric echo-planar spectroscopic imaging (3D EPSI) is presented that extends the region of the brain that can be observed. The data are sampled at higher spatial resolution, then corrected for local B(0) shifts and reconstructed such that the final spatial resolution matches that of 3D EPSI data acquired with the conventional lower spatial resolution. Comparison of in vivo data obtained at 1.5 T with these two acquisition schemes shows that the high spatial resolution acquisition provides considerable reduction of spectral linewidths in many problematic brain regions, though with a reduction in signal-to-noise ratio by a factor of approximately 1.4 to 1.6 for the matrix sizes used in this study. However, the effect of the increased noise was largely offset by the improved spectral quality, leading to an overall improvement of the metabolite image quality obtained using automated spectral analysis.

Brain↗