Survival after radical resection of cardiac sarcomas.
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to Andreas Hoffmeier.
Explore the source record for details and available documents.
AIMS: We sought to evaluate the utility of contrast-enhanced coronary magnetic resonance imaging (CE-MRI) for selective visualization and non-invasive differentiation of atherosclerotic coronary plaque in humans. METHODS AND RESULTS: Nine patients with coronary artery disease (CAD) as confirmed by X-ray angiography and multidetector computed tomography (MDCT) were studied by T1-weighted black blood inversion recovery coronary MRI before (N-IR) and after administration of Gd-DTPA (CE-IR). Plaques were categorized as calcified, non-calcified, and mixed based on their Hounsfield number derived from MDCT. With MDCT, a total of 29 plaques were identified, including calcified (n=6), non-calcified (n=6), and mixed calcified/non-calcified (n=17). On N-IR MRI, 26 plaques (90%) were dark, whereas three plaques (two non-calcified and one mixed) appeared bright. On CE-MRI, 13/29 (45%) plaques, 11 of which were mixed, one non-calcified, and one calcified showed contrast uptake. All others remained dark. CONCLUSION: In this preliminary study, we demonstrate the potential utility of CE-IR MRI for selective plaque visualization and differentiation of plaque types. The observed contrast uptake may be associated with endothelial dysfunction, neovascularization, inflammation, and/or fibrosis.
Explore the source record for details and available documents.
Primary cardiac lymphoma is an extremely rare extranodal non-Hodgkin's lymphoma, exclusively located in the heart and/or the pericardium with no evidence of extracardiac dissemination. In this report, we describe a cardiac B-cell lymphoma arising in a 70-year-old woman who presented to the hospital with heart failure symptoms and a high-degree atrioventricular block of unknown origin. Echocardiography revealed a massive infiltrative thickening of the atrial septum, the aortic root, and the pericardium. Pulsed wave and Doppler tissue findings were highly suggestive for pericarditis constrictiva. Positron emission tomography showed unusually strong metabolic activity in the atrial septum, both atria, and the entire pericardium. Suggested malignoma was confirmed by the pericardial biopsy specimens, which revealed a high-grade diffuse CD20+ B-cell lymphoma.
OBJECTIVE: Our objective was to compare two state-of-the-art coronary MRI (CMRI) sequences with regard to image quality and diagnostic accuracy for the detection of coronary artery disease (CAD). SUBJECTS AND METHODS: Twenty patients with known CAD were examined with a navigator-gated and corrected free-breathing 3D segmented gradient-echo (turbo field-echo) CMRI sequence and a steady-state free precession sequence (balanced turbo field-echo). CMRI was performed in a transverse plane for the left coronary artery and a double-oblique plane for the right coronary artery system. Subjective image quality (1- to 4-point scale, with 1 indicating excellent quality) and objective image quality parameters were independently determined for both sequences. Sensitivity, specificity, and accuracy for the detection of significant (> or = 50% diameter) coronary artery stenoses were determined as defined in invasive catheter X-ray coronary angiography. RESULTS: Subjective image quality was superior for the balanced turbo field-echo approach (1.8 +/- 0.9 vs 2.3 +/- 1.0 for turbo field-echo; p < 0.001). Vessel sharpness, signal-to-noise ratio, and contrast-to-noise ratio were all superior for the balanced turbo field-echo approach (p < 0.01 for signal-to-noise ratio and contrast-to-noise ratio). Of the 103 segments, 18% of turbo field-echo segments and 9% of balanced turbo field-echo segments had to be excluded from disease evaluation because of insufficient image quality. Sensitivity, specificity, and accuracy for the detection of significant coronary artery stenoses in the evaluated segments were 92%, 67%, 85%, respectively, for turbo field-echo and 82%, 82%, 81%, respectively, for balanced turbo field-echo. CONCLUSION: Balanced turbo field-echo offers improved image quality with significantly fewer nondiagnostic segments when compared with turbo field-echo. For the detection of CAD, both sequences showed comparable accuracy for the visualized segments.
BACKGROUND: B-type natriuretic peptide (BNP) is released from the cardiac ventricles in response to increased wall tension. We studied the relation of NT-proBNP to Heart Failure Survival Score (HFSS) and New York Heart Association (NYHA) class in patients with chronic heart failure (CHF). We also studied the impact for recipient selection for cardiac transplant and assessed it as a predictive and prognostic marker of CHF. METHODS: A total of 550 patients with dilative cardiomyopathy (n = 323), and coronary artery disease (n = 227) were prospectively examined. All patients underwent spiroergometry, echocardiography, right heart catheterization, and electrocardiogram. Routine blood levels and NT-proBNP were measured. The clinical selection for cardiac transplant candidates was adjudicated by 2 independent cardiologists who were blinded to the results of NT-proBNP assays. Clinical outcome and predictive power of NT-proBNP were analyzed. RESULTS: NT-proBNP levels in patients clinically considered for cardiac transplantation were significantly higher (2293 ng/ml vs 493 ng/ml; p < 0.001). The receiver operating characteristic (ROC) analysis regarding transplant candidacy showed an area under the ROC curve (AUC) of 0.84 +/- 0.01 for HFSS, 0.86 +/- 0.001 for NYHA, and 0.96 +/- 0.01 for NT-proBNP. Patients with increasing NT-proBNP levels or remaining elevated levels despite adequate heart insufficiency treatment were maintained with left ventricular assist device implantation (n = 10) or urgent heart transplantation (n = 2). Patients with NT-proBNP levels above 5000 pg/ml had a mortality rate of 28.4% per year. Twenty-eight patients died during the observation period; all these patients were within NYHA Classes 3 and 4 (NT-proBNP 5423 +/- 423 ng/ml). CONCLUSIONS: NT-proBNP discriminates patients at high likelihood of being a candidate for transplantation and provides prognostic informations in patients with CHF. NT-proBNP levels above 5000 pg/ml at admission were associated with death, and these levels markedly discriminated candidates for left ventricular assist devices or urgent transplantation.
BACKGROUND: The radial artery (RA) is increasingly used for myocardial revascularization because of its presumed advantageous long-term patency rates. The vessel can be harvested as a pedicle or skeletonized. The aim of this study was to compare the skeletonization technique with pedicle preparation using either an ultrasonic scalpel or scissors. METHODS: Forty consecutive patients with coronary artery disease undergoing complete arterial revascularization were included in the study. In 20 patients the RAs were prepared using scissors and clips (group 1: skeletonization; group 2: pedicle). In another 20 patients the arteries harvested were prepared using an ultrasonic scalpel (group 3: skeletonization; group 4: pedicle). The RA was treated with papaverine to prevent spasm of the vessel during and after harvesting. Tissue specimens of each RA were taken to analyze endothelial morphology by scanning electron microscopy. After implantation of the RA, graft perfusion was measured with a flow probe. RESULTS: Harvesting the RA as a skeletonized vessel took more time as compared with pedicle preparation (group 1 vs group 2: 37.1 +/- 3.5 minutes vs 24.4 +/- 3.9 minutes; p < 0.001 and group 3 vs group 4: 31.1 +/- 3.5 minutes vs 25.6 +/- 3.7 minutes; p < 0.01). The number of hemostatic titanium clips was similarly higher in group 1 as opposed to group 2 (58.7 +/- 7.1 vs 38.7 +/- 7.1; p < 0.01). However, there was no difference between groups 3 and 4 (p = 0.086). The length of the RA after skeletonization with scissors and clips was 20.8 +/- 1.5 cm in contrast with 19.1 +/- 0.9 cm (p < 0.01) after dissection as a pedicle. In the groups using the ultrasonic scalpel, there was no difference in graft length (p = 0.062). Mean blood flow through the graft after establishing the proximal anastomosis was similar among all groups (groups 1, 2, 3, and 4: 50 +/- 20.1 mL/min, 53.8 +/- 24.3 mL/min, 56.3 +/- 25.1 mL/min, and 51.8 +/- 23 mL/min, respectively). Scanning electron microscopy demonstrated endothelial damage in all patients in groups 1, 2, and 3 and in 7 patients of group 4. Most endothelial lesions were minor except in group 3 in which 1 of 5 endothelial lesions were severe. Statistically significant differences was found between groups 1 and 2, and 3 and 4 with respect to the degree of endothelial damage (p < 0.01). CONCLUSIONS: Skeletonization using scissors and clips is more time consuming and technically more difficult, but yield significantly longer grafts. Skeletonization with an ultrasonic scalpel did not result in additional length and was more frequently associated with severe endothelial damage. Pedicle preparation using scissors or an ultrasonic scalpel is much simpler and faster, and does not jeopardize endothelial integrity.
Explore the source record for details and available documents.
Hypersensitivity myocarditis is known to be a cardiac manifestation of a delayed-type hypersensitivity response caused by drug treatment. In heart transplantation candidates the incidence is elevated. We report the case of a patient with end-stage heart failure who underwent implantation of a left ventricular assist device as a bridge to transplantation. The histologic investigation of the left ventricular specimen obtained during device implantation revealed the diagnosis of a hypersensitivity myocarditis. Ten months later this lesion showed complete reversibility within specimens of the explanted heart, maybe as a result of the termination of inotropic therapy after implantation of the left ventricular assist device.
OBJECTIVES: To report the detection of a thrombus entrapped in a patent foramen ovale by echocardiography in a patient with recurrent pulmonary embolism. DESIGN: Case report. SETTING: Intensive care unit of a university hospital. PATIENT: A 62-yr-old man with initial deep venous thrombosis and recurrent minor pulmonary embolism followed by a severe embolic event with transitory hemiparesis 10 days after prostatectomy. INTERVENTION: Systemic anticoagulation, surgical removal of a crossing atrial thrombus, closure of a patent foramen ovale, and venous thrombectomy. MEASUREMENTS AND MAIN RESULTS: Transesophageal echocardiography revealed a large thrombus entrapped in a patent foramen ovale with portions in all four heart chambers. Intraoperatively, a 19-cm-long thrombus, shaped like the pelvic veins, was found. The patient was successfully weaned from cardiopulmonary bypass, requiring temporary positive inotropic support because of right ventricular dysfunction. Within 24 hrs of the operation, the patient was discharged to the intermediate care unit. CONCLUSIONS: Recurrent pulmonary embolism can potentially result in paradoxic embolism in patients with a patent foramen ovale. In such patients, it may be crucial to monitor right ventricular function and exclude right-to-left shunts by transesophageal echocardiography, regardless of clinical symptoms. The patent foramen ovale should be closed. This case emphasizes an important indication for transesophageal echocardiography in critically ill patients.