PubMed Health⌕ Search

Biomedical subjects

Andreas Kusterer

Publications and source records attributed to Andreas Kusterer.

2 recordsLinked to original sources

Methods and milliliter scale devices for high-throughput bioprocess design.

Based on electromagnetic simulations as well as on computational fluid dynamics simulations gas-inducing impellers and their magnetic inductive drive were optimized for stirred-tank reactors on a 10 ml-scale arranged in a bioreaction block with 48 bioreactors. High impeller speeds of up to 4,000 rpm were achieved at very small electrical power inputs (63 W with 48 bioreactors). The maxima of local energy dissipation in the reaction medium were estimated to be up to 50 W L(-1) at 2,800 rpm. Total power input and local energy dissipation are thus well comparable to standard stirred-tank bioreactors. A prototype fluorescence reader for 8 bioreactors with immobilized fluorometric sensor spots was applied for online measurement of dissolved oxygen concentration making use of the phase detection method. A self-optimizing scheduling software was developed for parallel control of 48 bioreactors with a liquid-handling system for automation of titration and sampling. It was shown on the examples of simple parallel batch cultivations of Escherichia coli with different media compositions that high cell densities of up to 16.5 g L(-1) dry cell mass can be achieved without pH-control within 5 h with a high parallel reproducibility (standard deviation<3.5%, n=48) due to the high oxygen transfer capability of the gas-inducing stirred-tank bioreactors.

Bioreactors↗

Miniature bioreactors for automated high-throughput bioprocess design (HTBD): reproducibility of parallel fed-batch cultivations with Escherichia coli.

To verify the reproducibility of cultivations of Escherichia coli in novel millilitre-scale bioreactors, fully automated fed-batch cultivation was performed in seven parallel-operated ml-scale bioreactors with an initial volume of 10 ml/reactor. The process was automatically controlled by a liquid-handling system responsible for glucose feeding, titration and sampling. Atline analysis (carried out externally of the reaction vessel with a short time delay) comprised automated pH and attenuance measurements. The partial pressure of oxygen (pO2) was measured online by a novel fluorimetric sensor block measuring the fluorescence lifetime of fluorophors immobilized inside the millilitre-scale bioreactors. Within a process time of 14.6 h, the parallel cultivation yielded a dry cell weight of 36.9+/-0.9 g.l(-1). Atline pH measurements were characterized by an S.D. of <1.1% throughout the process. Computational-fluid-dynamics simulation of single-phase flow yields a mean power input of 21.9 W.l(-1) at an impeller speed of 2800 rev./min corresponding to a power number (NP) of 3.7.

Automation↗