PubMed Health⌕ Search

Biomedical subjects

Andreas Manz

Publications and source records attributed to Andreas Manz.

6 recordsLinked to original sources

Micromixer-based time-resolved NMR: applications to ubiquitin protein conformation.

Time-resolved NMR spectroscopy is used to studychanges in protein conformation based on the elapsed time after a change in the solvent composition of a protein solution. The use of a micromixer and a continuous-flow method is described where the contents of two capillary flows are mixed rapidly, and then the NMR spectra of the combined flow are recorded at precise time points. The distance after mixing the two fluids and flow rates define the solvent-protein interaction time; this method allows the measurement of NMR spectra at precise mixing time points independent of spectral acquisition time. Integration of a micromixer and a microcoil NMR probe enables low-microliter volumes to be used without losing significant sensitivity in the NMR measurement. Ubiquitin, the model compound, changes its conformation from native to A-state at low pH and in 40% or higher methanol/water solvents. Proton NMR resonances of the His-68 and the Tyr-59 of ubiquitin are used to probe the conformational changes. Mixing ubiquitin and methanol solutions under low pH at microliter per minute flow rates yields both native and A-states. As the flow rate decreases, yielding longer reaction times, the population of the A-state increases. The micromixer-NMR system can probe reaction kinetics on a time scale of seconds.

Kinetics↗

Advances in capillary electrochromatography and micro-high performance liquid chromatography monolithic columns for separation science.

Over the last decade, monoliths or continuous beds have emerged as an alternative to traditional packed-bed columns for use in capillary electrochromatography (CEC) and micro-high performance liquid chromatography (micro-HPLC). Monolithic columns can be divided into two categories: silica-based monolithic columns and rigid organic polymer-based monolithic columns resulting from the polymerization of acrylamide, styrene, acrylate or methacrylate monomers. In this paper, the chemistry and most recent applications of these various types of monoliths in both CEC and micro-HPLC are presented.

Acrylates↗

Three-dimensional microfluidic confinement for efficient sample delivery to biosensor surfaces. application to immunoassays on planar optical waveguides.

A microchip-based flow confinement method for rapid delivery of small sample volumes to sensor surfaces is described. For flow confinement, a sample flow is joined with a perpendicular makeup flow of water or sample medium. Under laminar flow conditions, the makeup flow confines the sample into a thin layer above the sensing area and increases its velocity. This can benefit mass transport limited processes such as DNA hybridization or heterogeneous immunoassays. For proof of concept, this method was applied to a high-affinity immunoassay with excess capture antibody. Rabbit IgG was immobilized onto a silicon nitride waveguide. Cy5-labeled anti-rabbit IgG was hydrodynamically pumped over the immobilized zone through an attached 3D-PDMS flow cell with 20-microm-deep microchannels. The degree of confinement was adjusted through the volume flow rate of the confining flow. Evanescent field-based fluorescence detection enabled monitoring of the binding event. Assays were allowed to reach equilibrium to enable sensorgram normalization for inter-run comparison. The corresponding assay completion times could be reduced from 55 min for static drop conditions to 13 min for 25:1 flow confinement (ratio of confining to sample flow). For typical analytical applications, where equilibrium formation is not required, the faster response should translate to very short analysis times. Concurrently with the faster binding, sample consumption was reduced by 96% compared to conventional whole-channel sample delivery. Diffusional loss of analyte into the confining layer was identified as the main limitation of flow confinement, particularly for long sensing pads.

Biosensing Techniques↗

On-line on-chip post-column derivatisation reactions for pre-ionisation of analytes and cluster analysis in gradient micro-liquid chromatography/electrospray mass spectrometry.

A system is presented that demonstrates the principle of on-line and on-chip post-column derivatisation reactions in micro-high-performance liquid chromatography (micro-HPLC) hyphenated to electrospray time-of-flight mass spectrometry (ESI-TOFMS). In this micro-HPLC-chip-MS set-up, the analytes are separated using gradient micro-HPLC and subsequently derivatised on-chip and detected. One of the major limitations of MS detection is its dependency on the degree of ionisation, which is widely variable and compound-specific. Optimising and controlling the degree of ionisation in a simple manner would allow MS detection to be truly generic. One way of achieving this is by pre-ionisation of analytes using simple derivatisation procedures that are both rapid and quantitative. Performing this in situ on the system described here overcomes issues of sample handling and efficiency losses when time-consuming "bench chemistry" is necessary prior to analysis. The power of the system is demonstrated by the separation of primary and secondary amines, which are subsequently derivatised with a positively charged phosphonium complex and detected in an enhanced manner. Typically, molecular cations (M(+)) are detected showing that the ionisation process is dominated by the phosphonium species, leading to more constant ionisation for a variety of compounds. In addition, stable isotopically labelled ((12)C/(13)C)-phosphonium reagent is used for the reactions, allowing for inherent signal/noise (S/N) improvement and automated data processing using cluster analysis. A similar reaction scheme is used for the derivatisation of ketones and aldehydes, also demonstrating dramatic increases in sensitivity, especially with increasing temperature. Minimal loss in chromatographic fidelity in terms of retention times is observed by the introduction of the micromixer chip into the system. Optimal flow rates in micro-HPLC and ESI-MS are compatible with flow rates for the chip as well as a multitude of in-line optical detectors including UV and fluorescence. In addition, the micromixer chip can be positioned pre-column if preferred. The system is robust, easily fully automated and applicable to a wide variety of reactions. The system has a major advantage in its simple robust connection to the "normal scale" outside world.

Journal Article↗