PubMed Health⌕ Search

Biomedical subjects

Andreas O Frank

Publications and source records attributed to Andreas O Frank.

2 recordsLinked to original sources

Blood flow in stented arteries: a parametric comparison of strut design patterns in three dimensions.

BACKGROUND: Restenosis after stent implantation varies with stent design. Alterations in secondary flow patterns and wall shear stress (WSS) can modulate intimal hyperplasia via their effects on platelet and inflammatory cell transport toward the wall, as well as direct effects on the endothelium. METHOD OF APPROACH: Detailed flow characteristics were compared by estimating the WSS in the near-strut region of realistic stent designs using three-dimensional computational fluid dynamics (CFD), under pulsatile high and low flow conditions. The stent geometry employed was characterized by three geometric parameters (axial strut pitch, strut amplitude, and radius of curvature), and by the presence or lack of the longitudinal connector. RESULTS: Stagnation regions were localized around stent struts. The regions of low WSS are larger distal to the strut. Under low flow conditions, the percentage restoration of mean axial WSS between struts was lower than that for the high flow by 10-12%. The largest mean transverse shear stresses were 30-50% of the largest mean axial shear stresses. The percentage restoration in WSS in the models without the longitudinal connector was as much as 11% larger than with the connector The mean axial WSS restoration between the struts was larger for the stent model with larger interstrut spacing. CONCLUSION: The results indicate that stent design is crucial in determining the fluid mechanical environment in an artery. The sensitivity of flow characteristics to strut configuration could be partially responsible for the dependence of restenosis on stent design. From a fluid dynamics point of view, interstrut spacing should be larger in order to restore the disturbed flow; struts should be oriented to the flow direction in order to reduce the area of flow recirculation. Longitudinal connectors should be used only as necessary, and should be parallel to the axis. These results could guide future stent designs toward reducing restenosis.

Animals↗

Computational fluid dynamics and stent design.

Stents are small, usually metallic tubes that are intended to prop open arteries blocked with atherosclerotic plaques. While stents have been used successfully in recent years, they still suffer from failure due to development of new tissue in stented segment (restenosis). Variations in the failure rates associated with different stent designs have led researchers to investigate the role of near-wall flow patterns. While there is no direct evidence yet, the patterns of flow stagnation as the blood flows past the stent struts may affect the restenosis process. Computational fluid dynamics (CFD) approaches are well suited for obtaining detailed information on stent flow patterns. Many CFD simulations make use of a two-dimensional model. The strong dependence of flow stagnation on stent strut spacing has been clearly demonstrated. These results have been employed to interpret the results of in vitro experiments designed to elucidate the mechanisms of restenosis.

Arteriosclerosis↗