Spatially resolved non-invasive chemical stimulation for modulation of signalling in reconstructed neuronal networks.

Functional coupling of reconstructed neuronal networks with microelectronic circuits has potential for the development of bioelectronic devices, pharmacological assays and medical engineering. Modulation of the signal processing properties of on-chip reconstructed neuronal networks is an important aspect in such applications. It may be achieved by controlling the biochemical environment, preferably with cellular resolution. In this work, we attempt to design cell-cell and cell-medium interactions in confined geometries with the aim to manipulate non-invasively the activity pattern of an individual neuron in neuronal networks for long-term modulation. Therefore, we have developed a biohybrid system in which neuronal networks are reconstructed on microstructured silicon chips and interfaced to a microfluidic system. A high degree of geometrical control over the network architecture and alignment of the network with the substrate features has been achieved by means of aligned microcontact printing. Localized non-invasive on-chip chemical stimulation of micropatterned rat cortical neurons within a network has been demonstrated with an excitatory neurotransmitter glutamate. Our system will be useful for the investigation of the influence of localized chemical gradients on network formation and long-term modulation.

Animals↗

Suspended nanoporous membranes as interfaces for neuronal biohybrid systems.

A biohybrid system composed of neuronal cells and silicon-supported nanoporous membranes has been designed to facilitate control of the biochemical environment of neuronal networks with cellular resolution. The membranes may exhibit variable pore sizes and interpore distances and are interfaced to a microfluidic device. Different porosity parameters give rise to changes in the transconductance of the nanopores and can therefore be used to control diffusion of molecules through the membranes. It was shown that the porous membranes are biocompatible with primary vertebrate as well as insect neurons. Our results indicate that nanoporous membranes may be used to interface with biological materials in a biohybrid system, for example as an artificial chemical synapse interface.

Animals↗

Scanning probe microscopic studies of the oriented attachment and membrane reconstitution of cytochrome C oxidase to a gold electrode.

Scanning probe microscopy was used to monitor the resulting surface of the oriented incorporation of cytochrome c oxidase into electrode supported lipid bilayer at four crucial stages with molecular resolution. We were able to reveal the formation of a densely packed monolayer of the active ester dithio(succiniimidylepropionate) (DTSP) and the covalent linkage of the nitrilotriacetic acid (NTA) to the thiol anchored DTSP by scanning tunneling microscopy. Atomic force microscopy investigations showed that the detergent solubilized oxidase is immobilized as monomers and small aggregates via histidine residues. Finally, the reconstitution of the proteins within the supported membrane was verified. The amount of oxidase immobilized within the solid supported membrane was estimated.

Electrodes↗

Cell-transistor coupling: investigation of potassium currents recorded with p- and n-channel FETs.

Microelectronic-based biosensors that allow noninvasive measurement of cell activity are in the focus of current developments, however, the mechanisms underlying the cell-transistor coupling are not completely understood. In particular, characteristic properties of the extracellular voltage response such as the waveform and amplitude are not satisfactorily described by electrical circuit models. Here we examine the electrical coupling between a nonmetallized field-effect transistor (FET) and a cell line expressing a voltage-gated EAG K+ channel. The activation kinetics of this channel depends on the voltage pulse protocol and extracellular divalent cations. This feature allows testing, whether the extracellular voltage signal recorded with the FET faithfully tracks the current simultaneously recorded with the patch-clamp technique. We find that the FET signals contain different kinetic components that cannot be entirely explained by equivalent electrical-circuit models. Rather, we suggest that changes in ion concentration in the small cleft between cell and FET may change the surface potential of the FET. This study provides evidence that the electrochemical processes at the cell-transistor interface are complex and that at least two different mechanisms contribute to the shape and amplitude of transistor signals.

Action Potentials↗

N-Channel field-effect transistors with floating gates for extracellular recordings.

A field-effect transistor (FET) for recording extracellular signals from electrogenic cells is presented. The so-called floating gate architecture combines a complementary metal oxide semiconductor (CMOS)-type n-channel transistor with an independent sensing area. This concept allows the transistor and sensing area to be optimised separately. The devices are robust and can be reused several times. The noise level of the devices was smaller than of comparable non-metallised gate FETs. In addition to the usual drift of FET devices, we observed a long-term drift that has to be controlled for future long-term measurements. The device performance for extracellular signal recording was tested using embryonic rat cardiac myocytes cultured on fibronectin-coated chips. The extracellular cell signals were recorded before and after the addition of the cardioactive isoproterenol. The signal shapes of the measured action potentials were comparable to the non-metallised gate FETs previously used in similar experiments. The fabrication of the devices involved the process steps of standard CMOS that were necessary to create n-channel transistors. The implementation of a complete CMOS process would facilitate the integration of the logical circuits necessary for signal pre-processing on a chip, which is a prerequisite for a greater number of sensor spots in future layouts.

Action Potentials↗

Capillary zone electrophoresis of amino acids on a hybrid poly(dimethylsiloxane)-glass chip.

Poly(dimethylsiloxane) (PDMS)-PDMS and hybrid PDMS-glass devices have been characterized and compared in terms of current-voltage linearity, contact angle, electroosmotic velocity, electroosmotic mobility, and electrokinetic potential in dependence on the surface treatment. The hybrid PDMS-glass microfluidic devices have further been tested as on-chip capillary electrophoresis systems for the separation of fluorescently labeled amino acids. It has been demonstrated that different methods of surface pretreatment of the PDMS-glass devices result in significantly different separation performance, with plate numbers varying from 650 to 57 000 in dependence on the surface state and the nature of the amino acids. Electrophoretic separations of amino acids have been achieved within tens of seconds with detection limits of less than 2 microM (approximately 2 x 10(-16) to 2.5 x 10(-16) mol quantities at injection volumes of 110-120 pL). The detected amounts of fluorescein isothiocyante (FITC)-amino acids are at least ten times lower, since the amino acid:FITC ratio is 10:1 mol. The results demonstrate the perspective of such hybrid PDMS-glass microfluidic systems and the methods to modify their surfaces for on-chip separation methods for biomolecules.

Amino Acids↗

Neuron-transistor coupling: interpretation of individual extracellular recorded signals.

The electrical coupling of randomly migrating neurons from rat explant brain-stem slice cultures to the gates of non-metallized field-effect transistors (FETs) has been investigated. The objective of our work is the precise interpretation of extracellular recorded signal shapes in comparison to the usual patch-clamp protocols to evaluate the possible use of the extracellular recording technique in electrophysiology. The neurons from our explant cultures exhibited strong voltage-gated potassium currents through the plasma membrane. With an improved noise level of the FET set-up, it was possible to record individual extracellular responses without any signal averaging. Cells were attached by patch-clamp pipettes in voltage-clamp mode and stimulated by voltage step pulses. The point contact model, which is the basic model used to describe electrical contact between cell and transistor, has been implemented in the electrical simulation program PSpice. Voltage and current recordings and compensation values from the patch-clamp measurement have been used as input data for the simulation circuit. Extracellular responses were identified as composed of capacitive current and active potassium current inputs into the adhesion region between the cell and transistor gate. We evaluated the extracellular signal shapes by comparing the capacitive and the slower potassium signal amplitudes. Differences in amplitudes were found, which were interpreted in previous work as enhanced conductance of the attached membrane compared to the average value of the cellular membrane. Our results suggest rather that additional effects like electrodiffusion, ion sensitivity of the sensors or more detailed electronic models for the small cleft between the cell and transistor should be included in the coupling model.

Action Potentials↗

Synaptic plasticity in micropatterned neuronal networks.

Synaptic plasticity is thought to be of central importance for information processing by the nervous system. Additionally, specific neuronal connectivity patterns in the brain are implicated to play a role in the perception, processing and storage of incoming signals. Experimental control over connectivity within functional neuronal networks is therefore a promising approach in research on signal transduction and processing by the nervous system. A cell culture system is presented that allows experimental determination of neuronal connectivity patterns in an in vitro network. Rat embryonic cortical neurons were grown on patterns of extracellular matrix proteins applied to polystyrene substrates by microcontact printing. Cells comply well with the pattern and form synaptic connections along the experimentally defined pathways. Chemical synapses identified by double patch-clamp measurement showed paired pulse depression as well as frequency-dependent depression in response to trains of stimuli. This type of short-term plasticity has similarly been reported by others in brain slices. Thus, the system reproduces features central for neuronal information processing while the architecture of the network is experimentally manipulable. The ability to tailor the geometry of functional neuronal networks offers a valuable tool both for fundamental questions in neuroscientific research and a wide range of biotechnological applications.

Action Potentials↗

Membrane on a chip: a functional tethered lipid bilayer membrane on silicon oxide surfaces.

Tethered membranes have been proven during recent years to be a powerful and flexible biomimetic platform. We reported in a previous article on the design of a new architecture based on the self-assembly of a thiolipid on ultrasmooth gold substrates, which shows extremely good electrical sealing properties as well as functionality of a bilayer membrane. Here, we describe the synthesis of lipids for a more modular design and the adaptation of the linker part to silane chemistry. We were able to form a functional tethered bilayer lipid membrane with good electrical sealing properties covering a silicon oxide surface. We demonstrate the functional incorporation of the ion carrier valinomycin and of the ion channel gramicidin.

Biophysics↗

Impact of micropatterned surfaces on neuronal polarity.

Experimental control over cellular polarity in a neuronal network is a promising tool to study synapse formation and network behavior. We aimed to exploit a mechanism described by Stenger et al. [J. Neurosci. Methods 82 (1998) 167] to manipulate the direction of axonal versus dendritic outgrowth on a micropattern. The group had used laser ablation to create patterns of aminated silanes for cell attachment on a background of repellent fluorinated silanes. The pattern offered continuous adhesive pathways for axonal and interrupted pathways for dendritic outgrowth. By microcontact printing, we created similar patterns containing continuous and interrupted pathways consisting of extracellular matrix proteins on a background of polystyrene. Neuronal polarity was determined on the functional level through double patch clamp measurements, detecting synapses and their orientation. Although our pattern reproduced the properties that were assumed to be critical for the described effect, namely contrasting pathways of different adhesiveness, we failed to reproduce the above results. It is indicated that other qualities of alternative pathways than mere differences in adhesiveness are required to orient neuronal polarity in vitro. We suggest that the effect observed by Stenger et al. has to be attributed to less universal characteristics of the micropattern, e.g. to the specific chemical groups that were utilized.

Animals↗

Lateral diffusion in substrate-supported lipid monolayers as a function of ambient relative humidity.

We analyzed the influence of water activity on the lateral self-diffusion of supported phospholipid monolayers. Lipid monolayer membranes were supported by polysaccharide cushions (chitosan and agarose), or glass. A simple diffusion model was derived, based on activated diffusion with an activation energy, E(a), which depends on the hydration state of the lipid headgroup. A crucial assumption of the derived model is that E(a) can be calculated assuming an exponential decay of the humidity-dependent disjoining pressure in the monolayer/substrate interface with respect to the equilibrium separation distance. A plot of ln(D) against ln(p(0)/p), where D is the measured diffusion coefficient and p(0) and p are the partial water pressures at saturation and at a particular relative humidity, respectively, was observed to be linear in all cases (i.e., for differing lipids, lateral monolayer pressures, temperatures, and substrates), in accordance with the above-mentioned diffusion model. No indications for humidity-induced first-order phase transitions in the supported phospholipid monolayers were found. Many biological processes such as vesicle fusion and recognition processes involve dehydration/hydration cycles, and it can be expected that the water activity significantly affects the kinetics of these processes in a manner similar to that examined in the present work.

Biophysical Phenomena↗

PDMS device for patterned application of microfluids to neuronal cells arranged by microcontact printing.

A microfluidic device in polydimethylsiloxane (PDMS) consisting of an eight lines micro-injection array integrated in a base flow channel has been realized. The device is assembled from multiple PDMS parts, which have been moulded using notably micromachined masters in SU-8 photoresist. In contact with a planar substrate, up to eight independent laminar flow lines with cross-sections of 100 x 200 microm(2) can be generated. Dedicated for the application of pharmaceutical compounds to electrogenic cells in vitro, this device was tested with a neuronal cell line, Mz1-cells. These were cultured on lines of laminin deposited onto polystyrene substrates by microcontact printing. We were able to inject into this culture multiple lines of coloured PBS in parallel to the orientation of cellular growth. No mixing between the individual flow lines did occur.

Animals↗

Micropatterned substrates for the growth of functional neuronal networks of defined geometry.

The in vitro assembly of neuronal networks with control over cell position and connectivity is a fascinating approach not only for topics in basic neuroscience research but also in diverse applications such as biosensors and tissue engineering. We grew rat embryonic cortical neurons on patterned substrates created by microcontact printing. Polystyrene was used as a cell repellent background, onto which a grid pattern of physiological proteins was applied. We printed laminin and a mixture of extracellular matrix proteins and additionally both systems mixed with polylysine. Attachment of cells to the pattern with high fidelity as well as the formation of chemical synapses between neighboring cells on the pattern could be observed in all four cases, but cell attachment was strongly increased on samples containing polylysine. Neurons grown on patterned substrates had a membrane capacity smaller than that of neurons on homogeneously coated controls, which we attributed to the geometrical restrictions, but did not differ either in resting membrane potential or in the quality of synapses they formed. We therefore believe that the cells attach and differentiate normally on the pattern and form functional, mature synapses following the predefined geometry.

Action Potentials↗