PubMed Health⌕ Search

Biomedical subjects

Andrew B Slate

Publications and source records attributed to Andrew B Slate.

9 recordsLinked to original sources

Estimating deoxynivalenol in shelled corn barge lots by measuring deoxynivalenol in corn screenings.

To determine if deoxynivalenol (DON) is concentrated in small corn screenings, fourteen to twenty-three 1.1 kg test samples were taken from each of 10 barges of shelled corn. Each of the 181 test samples was divided into 2 components (fines and clean) using a 5 mm screen. The clean component sample rode the 5 mm screen and the fines component sample passed through the 5 mm screen. The DON concentration in fines component sample was about 3 times the DON concentration in the clean component sample. The DON in the 181 fines and clean component samples averaged 689.0 and 206.1 ng/g, respectively. Regression equations were developed to predict the DON in the barge based upon measurements of DON in the fines component sample. The ratio of DON in the lot to DON in the fines component sample was 0.359. The coefficient of variation (CV) associated with predicting the DON concentration in a lot with 359 ng/g using a 1.1 kg test sample was 47.0%. Increasing sample size to 4.4 kg reduced the CV to 23%.

Algorithms↗

Testing green coffee for ochratoxin A, part I: estimation of variance components.

The variability associated with testing lots of green coffee beans for ochratoxin A (OTA) was investigated. Twenty-five lots of green coffee were tested for OTA contamination. The total variance associated with testing green coffee was estimated and partitioned into sampling, sample preparation, and analytical variances. All variances increased with an increase in OTA concentration. Using regression analysis, mathematical expressions were developed to model the relationship between OTA concentration and the total, sampling, sample preparation, and analytical variances. The expressions for these relationships were used to estimate the variance for any sample size, subsample size, and number of analyses for a specific OTA concentration. Testing a lot with 5 microg/kg OTA using a 1 kg sample, Romer RAS mill, 25 g subsamples, and liquid chromatography analysis, the total, sampling, sample preparation, and analytical variances were 10.75 (coefficient of variation [CV] = 65.6%), 7.80 (CV = 55.8%), 2.84 (CV = 33.7%), and 0.11 (CV = 6.6%), respectively. The total variance for sampling, sample preparation, and analytical were 73, 26, and 1%, respectively.

Algorithms↗

Variation of analytical results for peanuts in energy bars and milk chocolate.

Peanuts contain proteins that can cause severe allergic reactions in some sensitized individuals. Studies were conducted to determine the percentage of recovery by an enzyme-linked immunosorbent assay (ELISA) method in the analysis for peanuts in energy bars and milk chocolate and to determine the sampling, subsampling, and analytical variances associated with testing energy bars and milk chocolate for peanuts. Food products containing chocolate were selected because their composition makes sample preparation for subsampling difficult. Peanut-contaminated energy bars, noncontaminated energy bars, incurred milk chocolate containing known levels of peanuts, and peanut-free milk chocolate were used. A commercially available ELISA kit was used for analysis. The sampling, sample preparation, and analytical variances associated with each step of the test procedure to measure peanut protein were determined for energy bars. The sample preparation and analytical variances were determined for milk chocolate. Variances were found to be functions of peanut concentration. Sampling and subsampling variability associated with energy bars accounted for 96.6% of the total testing variability. Subsampling variability associated with powdered milk chocolate accounted for >60% of the total testing variability. The variability among peanut test results can be reduced by increasing sample size, subsample size, and number of analyses. For energy bars the effect of increasing sample size from 1 to 4 bars, subsample size from 5 to 20 g, and number of aliquots quantified from 1 to 2 on reducing the sampling, sample preparation, and analytical variance was demonstrated. For powdered milk chocolate, the effects of increasing subsample size from 5 to 20 g and number of aliquots quantified from 1 to 2 on reducing sample preparation and analytical variances were demonstrated. This study serves as a template for application to other foods, and for extrapolation to different sizes of samples and subsamples as well as numbers of analyses.

Allergens↗

Evaluation of sampling plans to detect Cry9C protein in corn flour and meal.

StarLink is a genetically modified corn that produces an insecticidal protein, Cry9C. Studies were conducted to determine the variability and Cry9C distribution among sample test results when Cry9C protein was estimated in a bulk lot of corn flour and meal. Emphasis was placed on measuring sampling and analytical variances associated with each step of the test procedure used to measure Cry9C in corn flour and meal. Two commercially available enzyme-linked immunosorbent assay kits were used: one for the determination of Cry9C protein concentration and the other for % StarLink seed. The sampling and analytical variances associated with each step of the Cry9C test procedures were determined for flour and meal. Variances were found to be functions of Cry9C concentration, and regression equations were developed to describe the relationships. Because of the larger particle size, sampling variability associated with cornmeal was about double that for corn flour. For cornmeal, the sampling variance accounted for 92.6% of the total testing variability. The observed sampling and analytical distributions were compared with the Normal distribution. In almost all comparisons, the null hypothesis that the Cry9C protein values were sampled from a Normal distribution could not be rejected at 95% confidence limits. The Normal distribution and the variance estimates were used to evaluate the performance of several Cry9C protein sampling plans for corn flour and meal. Operating characteristic curves were developed and used to demonstrate the effect of increasing sample size on reducing false positives (seller's risk) and false negatives (buyer's risk).

Algorithms↗

Immunochemical analytical methods for the determination of peanut proteins in foods.

Peanut proteins can cause allergenic reactions that can result in respiratory and circulatory effects in the body sometimes leading to shock and death. The determination of peanut proteins in foods by analytical methods can reduce the risk of serious reactions in the highly sensitized individual by allowing for the detection of these proteins in a food at various stages of the manufacturing process. The method performance of 4 commercially available enzyme-linked immunosorbent assay (ELISA) kits was evaluated for the detection of peanut proteins in milk chocolate, ice cream, cookies, and breakfast cereals: ELISA-TEK Peanut Protein Assay, now known as "Bio-Kit" for peanut proteins, from ELISA Technologies Inc.; Veratox for Peanut Allergens from Neogen Corp.; RIDASCREEN Peanut Kit from R-Biopharm GmbH; and ProLisa from Canadian Food Technology Ltd. The 4 test kits were evaluated for accuracy (recovery) and precision using known concentrations of peanut or peanut proteins in the 4 food matrixes. Two different techniques, incurred and spiked, were used to prepare samples with 4 known concentrations of peanut protein. Defatted peanut flour was added in the incurred samples, and water-soluble peanut proteins were added in the spiked samples. The incurred levels were 0.0, 10, 20, and 100 microg whole peanut per g food; the spiked levels were 0.0, 5, 10, and 20 microg peanut protein per g food. Performance varied by test kit, protein concentration, and food matrix. The Veratox kit had the best accuracy or lowest percent difference between measured and incurred levels of 15.7% when averaged across all incurred levels and food matrixes. Recoveries associated with the Veratox kit varied from 93 to 115% for all food matrixes except cookies. Recoveries for all kits were about 50% for cookies. The analytical precision, as measured by the variance, increased with an increase in protein concentration. However, the coefficient of variation (CV) was stable across the 4 incurred protein levels and was 7.0% when averaged across the 4 food matrixes and analytical kits. The R-Biopharm test kit had the best precision or a CV of 4.2% when averaged across all incurred levels and food matrixes. Because measured protein values varied by test kit and food matrix, a method was developed to normalize or transform measured protein concentrations to an adjusted protein value that was equal to the known protein concentration. The normalization method adjusts measured protein values to equal the true protein value regardless of the type test kit or type food matrix.

Allergens↗

Testing green coffee for ochratoxin A, part II: Observed distribution of ochratoxin A test results.

The suitability of 4 theoretical distributions (normal, lognormal, negative binomial, and gamma) to predict the observed distribution of ochratoxin A (OTA) in green coffee was investigated. One symmetrical and 3 positively skewed theoretical distributions were each fitted to 25 empirical distributions of OTA test results for green coffee beans. Parameters of each theoretical distribution were calculated by using Methods of Moments. The 3 skewed theoretical distributions provided acceptable fits to each of the 25 observed distributions. Because of its simplicity, the lognormal distribution was selected to model OTA test results for green coffee. Using variance equations determined in previous studies, mathematical expressions were developed to calculate the parameters of the log normal distribution for a given OTA lot concentration and test procedure. Observed acceptance probabilities were compared to an operating characteristic curve predicted from the lognormal distribution, and all 25 observed acceptance probabilities were found to lie within the 95% confidence band associated with the predicted operating characteristic curve. The parameters of compound gamma distribution were used to calculate the fraction of OTA contamination beans within a contaminated lot. The percent-contaminated beans were a function of the lot concentration and increased with lot concentration. At a lot concentration of 5 microg/kg, approximately 6 beans per 10,000 beans are contaminated.

Buffers↗

Sampling hazelnuts for aflatoxin: uncertainty associated with sampling, sample preparation, and analysis.

The variability associated with the aflatoxin test procedure used to estimate aflatoxin levels in bulk shipments of hazelnuts was investigated. Sixteen 10 kg samples of shelled hazelnuts were taken from each of 20 lots that were suspected of aflatoxin contamination. The total variance associated with testing shelled hazelnuts was estimated and partitioned into sampling, sample preparation, and analytical variance components. Each variance component increased as aflatoxin concentration (either B1 or total) increased. With the use of regression analysis, mathematical expressions were developed to model the relationship between aflatoxin concentration and the total, sampling, sample preparation, and analytical variances. The expressions for these relationships were used to estimate the variance for any sample size, subsample size, and number of analyses for a specific aflatoxin concentration. The sampling, sample preparation, and analytical variances associated with estimating aflatoxin in a hazelnut lot at a total aflatoxin level of 10 ng/g and using a 10 kg sample, a 50 g subsample, dry comminution with a Robot Coupe mill, and a high-performance liquid chromatographic analytical method are 174.40, 0.74, and 0.27, respectively. The sampling, sample preparation, and analytical steps of the aflatoxin test procedure accounted for 99.4, 0.4, and 0.2% of the total variability, respectively.

Aflatoxins↗

Testing green coffee for ochratoxin A, part III: performance of ochratoxin A sampling plan.

Green coffee shipments are often inspected for ochratoxin A (OTA) and classified into good or bad categories depending on whether the OTA estimates are above or below a defined regulatory limit. Because of the uncertainty associated with the sampling, sample preparation, and analytical steps of an OTA test procedure, some shipments of green coffee will be misclassified. The misclassification of lots leads to some good lots being rejected (sellers' risk) and some bad lots being accepted (buyers' risk) by an OTA sampling plan. Reducing the uncertainty of an OTA test procedure and using an accept/reject limit less than the regulatory limit can reduce the magnitude of one or both risks. The uncertainty of the OTA test procedure is most effectively reduced by increasing sample size (or increasing the number of samples analyzed), because the sampling step is the largest source of uncertainty in the OTA test procedure. The effects of increasing sample size and changing the sample accept/reject limit relative to the regulatory limit on the performance of OTA sampling plans for green coffee were investigated. For a given accept/reject limit of 5 microg/kg, increasing sample size increased the percentage of lots accepted at concentrations below the regulatory limit and increased the percentage of lots rejected at concentrations above the regulatory limit. As a result, increasing sample size reduced both the number of good lots rejected (sellers' risk) and the number of bad lots accepted (buyers' risk). For a given sample size (1 kg), decreasing the sample accept/reject limit from 5 to 2 microg/kg relative to a fixed regulatory limit of 5 microg/kg decreased the percentage of lots accepted and increased the percentage of lots rejected at all OTA concentrations. As a result, decreasing the accept/reject limit below the regulatory limit increased the number of good lots rejected (sellers' risk), but decreased the number of bad lots accepted (buyers' risk).

Carcinogens↗

Sampling almonds for aflatoxin, part I: estimation of uncertainty associated with sampling, sample preparation, and analysis.

Domestic and international regulatory limits have been established for aflatoxin in almonds and other tree nuts. It is difficult to obtain an accurate and precise estimate of the true aflatoxin concentration in a bulk lot because of the uncertainty associated with the sampling, sample preparation, and analytical steps of the aflatoxin test procedure. To evaluate the performance of aflatoxin sampling plans, the uncertainty associated with sampling lots of shelled almonds for aflatoxin was investigated. Twenty lots of shelled almonds were sampled for aflatoxin contamination. The total variance associated with measuring B1 and total aflatoxins in bulk almond lots was estimated and partitioned into sampling, sample preparation, and analytical variance components. All variances were found to increase with an increase in aflatoxin concentration (both B1 and total). By using regression analysis, mathematical expressions were developed to predict the relationship between each variance component (total, sampling, sample preparation, and analysis variances) and aflatoxin concentration. Variance estimates were the same for B1 and total aflatoxins. The mathematical relationships can be used to estimate each variance for a given sample size, subsample size, and number of analyses other than that measured in the study. When a lot with total aflatoxins at 15 ng/g was tested by using a 10 kg sample, a vertical cutter mixer type of mill, a 100 g subsample, and high-performance liquid chromatography analysis, the sampling, sample preparation, analytical, and total variances (coefficient of variation, CV) were 394.7 (CV, 132.4%), 14.7 (CV, 25.5%), 0.8 (CV, 6.1%), and 410.2 (CV, 135.0%), respectively. The percentages of the total variance associated with sampling, sample preparation, and analytical steps were 96.2, 3.6, and 0.2, respectively.

Aflatoxin B1↗