PubMed Health⌕ Search

Biomedical subjects

Andrew D Speirs

Publications and source records attributed to Andrew D Speirs.

2 recordsLinked to original sources

Physiologically based boundary conditions in finite element modelling.

Finite element analysis has been used extensively in the study of bone loading and implant performance, such as in the femur. The boundary conditions applied vary widely, generally producing excessive femoral deformation, and although it has been shown that the muscle forces influence femoral deflections and loading, little consideration has been given to the displacement constraints. It is hypothesised that careful application of physiologically based constraints can produce physiological deformation, and therefore straining, of the femur. Joint contact forces and a complete set of muscle forces were calculated based on the geometry of the Standardised Femur using previously validated musculoskeletal models. Five boundary condition cases were applied to a finite element model of the Standardised Femur: (A) diaphyseally constrained with hip contact and abductor forces; (B) case A plus vasti forces; (C) case A with complete set of muscle forces; (D) distally constrained with all muscle forces; (E) physiological constraints with all muscle forces. It was seen that only the physiological boundary conditions, case E, produced physiological deflections (< 2.0mm) of the femoral head in both the coronal and sagittal planes, which resulted in minimal reaction forces at the constrained nodes. Strains in the mid-diaphysis varied by up to 600 micro-strain under walking loads and 1000 micro-strain under stair climbing loads. The mode of loading, as indicated by the strain profiles on the cortex also varied substantially under these boundary conditions, which has important consequences for studies that examine localised bone loading such as fracture or bone remodelling simulations.

Compressive Strength↗

Calcium phosphate cement composites in revision hip arthroplasty.

Loosening of the femoral component in a total hip arthroplasty with concomitant bone loss can pose a problem for revision surgery due to inadequate structure in the remaining femur. While impaction allografting has shown promise, it has also shown serious complications, especially with moderate to severe bone loss. It may be possible to stabilize the graft layer with a bioresorbable cement to improve clinical results. This study examines the mechanical properties of a potential morsellized bone-bioresorbable composite. Morsellized bone was mixed with a commercially available bioresorbable cement (alpha-BSM, Etex Corp.) in compositions of 0%, 25%, 50% and 75% bone. Unconfined compression and diametral tensile and confined compression tests were performed to determine the composite mechanical properties. The composition containing 50% bone tended to exhibit the highest uniaxial strengths, as well as the highest confined compression modulus. The uniaxial compressive strength and stiffness of this composition was in the range of cancellous bone. Uniaxial compressive modulus decreased with increasing bone fraction whereas elongation exhibited the opposite trend. Bone fraction had a significant effect on compressive strength (p < 0.0001), compressive modulus (p < 0.0001), elongation (p < 0.01), tensile strength (p < 0.0001) and confined compressive modulus (p = 0.04). The addition of a bioresorbable cement to the allograft layer may improve the properties of the layer, preventing early subsidence seen in some clinical studies of impaction allografting, and therefore improving the clinical results. Further testing is required to evaluate the in vitro mechanical performance, as well as in vivo remodelling characteristics.

Aged↗