Preparative linear ion trap mass spectrometer for separation and collection of purified proteins and peptides in arrays using ion soft landing.

A preparative mass spectrometer for microarray fabrication is reported. The instrument includes an atmospheric pressure ionization source, a linear ion trap mass analyzer, an ion collection surface positioning system, and a surface loading chamber with independent vacuum pumping. It was designed for the production of protein arrays using the ion soft-landing technique to collect ions on a surface after separation by mass/charge ratio. Small microarrays have been prepared by isolating and soft landing individual protein or peptide ions after electrospray ionization of mixtures. The composition and purity of the separated materials has been confirmed using independent external mass spectrometric analysis of rinse solutions of the collected spots, either by the new method of electrosonic spray ionization MS or by nanospray ionization MS. The ability to retain bioactivity in the mass-selected and collected biomolecules has been demonstrated in particular cases. The reported instrument has also been characterized as an analytical mass spectrometer.

Amino Acid Sequence↗

High-throughput miniature cylindrical ion trap array mass spectrometer.

A fully multiplexed cylindrical ion trap (CIT) array mass spectrometer with four parallel ion source/mass analyzer/detector channels has been built to allow simultaneous high-throughput analysis of multiple samples. A multielement external chemical ionization/electron ionization source was coupled to a parallel array of CITs each of equal size (internal radius 2.5 mm), and the signal was recorded using an array of four miniature (2-mm inner diameter) electron multipliers. Using external electron ionization, the spectra of four separate samples were recorded simultaneously in real time using a four-channel preamplifier system and a data acquisition program written using LabVIEW software. These experiments mark the first demonstration of externally generated ions being successfully trapped in a miniature CIT mass analyzer. The instrument currently provides mass/charge range of approximately m/z 50-500. Average peak width is m/z 0.3, corresponding to a resolution of 1000 at m/z 300. The four-channel mass spectrometer is housed in a single vacuum manifold and operated with a single set of control electronics. The modular design of this instrument allows scale-up to many more channels of analysis for future applications in the areas of industrial process monitoring and combinatorial analysis and in the fields of proteomics and metabolomics.

Journal Article↗

Miniature cylindrical ion trap mass spectrometer.

A miniature cylindrical ion trap mass spectrometer is described, and preliminary data are presented. Functionality and performance of laboratory-scale instruments have been maintained to the extent possible in this battery-operated mass spectrometer. Capabilities include tandem mass spectrometry experiments. Custom-designed electronic components include the RF scanning and amplification system, data acquisition components, and lens power supplies, as well as a custom-software application. Direct leak and membrane introduction inlet systems are used for sample introduction. A mass/charge range of approximately 250 Th with unit mass resolution has been demonstrated.

Journal Article↗