MRI of the coronary vessel wall at 3 T: comparison of radial and cartesian k-space sampling.

OBJECTIVE: The purpose of our study was to compare the quality of 3D gradient-echo images obtained using radial versus cartesian k-space sampling at 3 T. CONCLUSION: This study shows that the quality of coronary vessel wall imaging of the right coronary artery with radial k-space sampling in 3D turbo field-echo sequences is superior to cartesian k-space sampling at 3 T. Radial k-space sampling at 3 T makes it possible to combine low motion artifact susceptibility with high signal-to-noise ratio.

Adult↗

Investigation of atherosclerotic plaques with MRI at 3 T using ultrasmall superparamagnetic particles of iron oxide.

This study aims to investigate the uptake of the experimental ultrasmall superparamagnetic particles of iron oxide (USPIO) contrast agent DDM43/34 (Schering AG, Berlin, Germany) by aortic atherosclerotic plaques using magnetic resonance imaging (MRI) at 3 T. Six Watanabe heritable hyperlipidemic rabbits were injected with USPIO at doses of 0.1-1.0 mmol/kg Fe. Parasagittal magnetic resonance angiography (MRA) scans were acquired using 3D gradient-echo sequences before and after USPIO administration, then again after 6 h, 1 day, 2 days and 5 days. At later time points, when the USPIO concentration was too low to enhance blood signal, additional MRA scans were acquired during the infusion of gadopentate dimeglumine (Magnevist; Schering AG). In the images, widespread susceptibility artifacts demonstrated readily detectable USPIO uptake in the liver, bone marrow and lymphatic vessels. Surprisingly, however, no such effects could be associated specifically with the aortic vessel wall, in contrast to previous studies that showed strong uptake with similar pulse sequences. Histological analysis was performed on aortic slices from two animals, demonstrating that aortic plaques were active but showed very little USPIO uptake, consistent with MRI findings. We conclude that, despite the exciting potential of plaque detection using USPIO, some caution is advised since the absence of susceptibility effects does not necessarily imply the absence of plaque, even at 3 T, which offers increased sensitivity to susceptibility. Future work will investigate the dependence of such results on stage of plaque development, magnetic field strength and choice of contrast agent.

Animals↗

Coronary vessel-wall and lumen imaging using radial k-space acquisition with MRI at 3 Tesla.

This study investigates the feasibility of imaging the coronary lumen and vessel-wall, using MRI with a radial k-space trajectory at 3 T. Such radial trajectories offer the advantage of greater vessel sharpness than traditional Cartesian trajectories. This field strength offers an increased signal-to-noise ratio (SNR) compared with 1.5 T, which compensates for the slight SNR reduction due to the radial sequence. Images of the coronary lumen were acquired for seven healthy volunteers. In ten volunteers the vessel wall was scanned, with blood suppression using oblique-slab adiabatic re-inversion. Scans were performed during free breathing, using prospective respiratory navigator-gating. Coronary lumen scans had SNR of 16.0+/-1.9 and contrast-to-noise ratio (CNR) of 10.3+/-2.1, showing acceptable image quality. Vessel wall images showed good image quality, with mean SNR of 16.6+/-2.0/5.8+/-2.8/10.1+/-2.2 for vessel wall/lumen/epicardial fat. The wall-blood CNR was 10.7+/-2.7, and wall-fat CNR was 6.5+/-2.5. It is concluded that radial gradient-echo imaging at 3 T is a promising method for coronary vessel-wall imaging, and is also feasible for imaging the coronary lumen.

Adipose Tissue↗

Functional MR imaging: comparison of BOLD signal intensity changes in fetal organs with fetal and maternal oxyhemoglobin saturation during hypoxia in sheep.

PURPOSE: To compare relative changes in blood oxygen level-dependent (BOLD) signal intensity in the fetal brain, liver, heart, lungs, and cotyledon with maternal and fetal blood oxygenation during maternal hypoxia in sheep. MATERIALS AND METHODS: All experimental protocols were reviewed and approved by local authorities on animal protection. Six anesthetized ewes carrying singleton fetuses underwent magnetic resonance (MR) imaging with rapid single-shot echo-planar imaging BOLD sequence. BOLD imaging of the fetal brain, lungs, liver, heart, and cotyledon was performed during a control phase (ie, normoxia) and a hypoxic phase. Maternal oxyhemoglobin saturation was recorded continuously with pulse oximetry. Fetal blood samples were obtained with a carotid catheter at each phase. Regions of interest were placed in fetal organs. Normalized BOLD signal intensity was calculated with mean values of control and hypoxic plateaus. BOLD signal intensity was correlated with maternal oxyhemoglobin saturation and fetal oxyhemoglobin saturation; linear regression analysis was performed. RESULTS: Control maternal and fetal oxyhemoglobin saturation values were 97% (95% confidence interval [CI]: 95%, 100%) and 62% (95% CI: 51%, 73%), respectively. During hypoxia, maternal and fetal oxyhemoglobin saturation values decreased to 75% (95% CI: 65%, 85%) and 23% (95% CI: 17%, 29%), respectively. Fetal BOLD signal intensity decreased to 81% (95% CI: 73%, 88%) in the cerebrum, 78% (95% CI: 67%, 89%) in the cerebellum, 83% (95% CI: 80%, 86%) in the lungs, 58% (95% CI: 33%, 84%) in the liver, 53% (95% CI: 43%, 64%) in the heart, and 71% (95% CI: 48%, 94%) in the cotyledon. Correlation of fetal BOLD signal intensity was stronger with fetal (r = 0.91) than with maternal (r = 0.68) oxyhemoglobin saturation; however, the difference was not significant. The highest slope values were obtained for the heart: 1.68% BOLD signal intensity increase per 1% maternal oxyhemoglobin saturation (95% CI: 1.58, 1.77) and 1.04% BOLD signal intensity increase per 1% fetal oxyhemoglobin saturation (95% CI: 0.94, 1.13). CONCLUSION: BOLD MR imaging can be used to measure changes of oxyhemoglobin saturation in fetal organs during hypoxia. The liver and heart demonstrated the greatest signal intensity decreases during hypoxia.

Analysis of Variance↗

EPI distortion correction from a simultaneously acquired distortion map using TRAIL.

PURPOSE: To develop a method for shot-by-shot distortion correction of single-shot echo-planar imaging (EPI) that is capable of correcting each image individually using a distortion measurement performed during acquisition of the image itself. MATERIALS AND METHODS: The recently-introduced method known as two reduced acquisitions interleaved (TRAIL) was extended to measure the distribution of the main magnetic field B0 with each shot. This corresponded to a map of distortion, and allowed distortion to be corrected in the acquired images. RESULTS: Distortion-corrected images were demonstrated in the human brain. The distortion field could be directly visualized using the "stripe" distribution imposed by the TRAIL pulse sequence. This confirmed the success of the correction. Over a time-course measurement of 10 images, variance was reduced by using shot-by-shot distortion correction compared to correction with a constant field map. CONCLUSION: Shot-by-shot distortion correction may be performed for EPI images acquired using an extension of the TRAIL technique, ensuring that the correction reflects the actual distortion pattern and not merely a previously measured, but possibly no longer valid, distortion field. This avoids errors due to changes in the distortion field or misregistration of a previously measured distortion map resulting from subject motion.

Brain Mapping↗

Comparative prognostic utilities of early quantitative magnetic resonance imaging spin-spin relaxometry and proton magnetic resonance spectroscopy in neonatal encephalopathy.

OBJECTIVE: We sought to compare the prognostic utilities of early MRI spin-spin relaxometry and proton magnetic resonance spectroscopy in neonatal encephalopathy. METHODS: Twenty-one term infants with neonatal encephalopathy were studied at a mean age of 3.1 days (range: 1-5). Basal ganglia, thalamic and frontal, parietal, and occipital white matter spin-spin relaxation times were determined from images with echo times of 25 and 200 milliseconds. Metabolite ratios were determined from an 8-mL thalamic-region magnetic resonance spectroscopy voxel (1H point-resolved spectroscopy; echo time 270 milliseconds). Outcomes were assigned at age 1 year as follows: (1) normal, (2) moderate (neuromotor signs or Griffiths developmental quotient of 75-84), (3) severe (functional neuromotor deficit or developmental quotient <75 or died). Predictive efficacies for differentiation between normal and adverse (combined moderate and severe) outcomes were compared by receiver operating characteristic curve analysis and logistic regression. RESULTS: Thalamic and basal ganglia spin-spin relaxation times correlated positively with outcome and predicted adversity. Although thalamic and basal ganglia spin-spin relaxation times were prognostic of adversity, magnetic resonance spectroscopy metabolite ratios were better predictors, and, of these, lactate/N-acetylaspartate was most accurate. CONCLUSIONS: Deep gray matter spin-spin relaxation time was increased in the first few days after birth in infants with an adverse outcome. Proton magnetic resonance spectroscopy was more prognostic than spin-spin relaxation time, with lactate/N-acetylaspartate the best measure. Nevertheless, both techniques were useful for early prognosis, and the potential superior spatial resolution of spin-spin relaxometry may define better the precise anatomic pattern of injury in the early days after birth.

Brain Chemistry↗

Growth restriction and the cerebral metabolic response to acute hypoxia of chick embryos in-ovo: a proton magnetic resonance spectroscopy study.

INTRODUCTION: Perinatal brain injury is more common in growth-restricted (GR) than normally grown (NG) fetuses. This study addresses the hypothesis that chronic oxygen and substrate deprivation during pregnancy will engender an abnormal fetal cerebral metabolic response to acute hypoxia. METHOD: Cerebral metabolite resonance amplitudes relative to that of creatine were measured by proton magnetic resonance spectroscopy in chick embryos on day 19 of incubation. Measurements were obtained before, during and after acute hypoxia (8% ambient oxygen concentration for 44 min) in NG and GR embryos (10% albumen extracted day 0 and 14% oxygen exposure from day 10 of incubation). RESULTS: In both NG and GR embryos, the cerebral lactate/creatine increased during acute hypoxia and slowly recovered after restoration of normoxia. However, the mean (+/-SD) increase in lactate/creatine was significantly less in GR compared to NG embryos (0.51 +/- 0.36 vs. 0.94 +/- 0.36; P = 0.02, t test). Alanine increased during acute hypoxia in NG but not GR embryos. Mean beta-hydroxybutyrate was increased only in GR embryos (0.63 +/- 0.01 vs. 0.22 +/- 0.01; P < 0.001, ANOVA). CONCLUSIONS: Acute hypoxia increases cerebral lactate and alanine in NG chick embryos; these increases are reduced by pre-exposure to substrate deprivation and chronic hypoxia.

3-Hydroxybutyric Acid↗

Common SENSE (sensitivity encoding using hardware common to all MR scanners): a new method for single-shot segmented echo planar imaging.

A new method is presented that enables image acquisition to be segmented into two readouts. This is achieved using a new pulse sequence that creates two components of magnetization with different spatial profiles. Each component of the magnetization is measured in one of the readouts. This produces two images with complimentary "sensitivity profiles" and near identical contrast. The images can be acquired with a reduced data matrix that corresponds to shorter periods of data acquisition. The reduced matrix images are then combined to produce a full matrix image using reconstruction methods previously applied to images from multiple RF coils in the sensitivity encoding (SENSE) technique. The most promising application for this technique is in improving the performance of echo planar imaging (EPI) at high field. In this application, common SENSE obtains two segments of data in a single excitation of the magnetization (i.e., two readouts are performed per shot). The combination of these segments in image space avoids the difficulties normally associated with segmented EPI methods, namely, increased ghosting from discontinuities in the k-space data. The main advantages are a reduction in distortion and blurring. Common SENSE is compatible with parallel imaging and partial Fourier methods.

Echo-Planar Imaging↗

Magnetic resonance imaging of the coronary vessel wall at 3 T using an obliquely oriented reinversion slab with adiabatic pulses.

Three-dimensional methods offer volumetric coverage in coronary vessel wall imaging, in addition to high signal-to-noise ratios (SNR). To increase SNR further, it is desirable to implement such 3D methods at 3 T. At this field strength, the pulse sequence must be robust to main field and RF inhomogeneities. To achieve this, the double inversion-recovery (DIR) preparation was adapted to use adiabatic pulses, with a slab-selective reinversion replacing the previously used 2D pencil-beam. The slab was oriented obliquely, in order to avoid upstream blood (e.g., left ventricle) or the navigator beam. Phantom experiments suggest that at 3 T, this approach improves both the net profile of the DIR pulse pair and the restoration of magnetization in the navigator region. Using this method, the feasibility of 3D coronary vessel wall imaging was demonstrated at 3 T. Fourteen healthy subjects were scanned using a segmented gradient-echo sequence with prospective navigator gating. Good-quality images of left and right coronary arteries were obtained, with SNR values of 29.7 +/- 7.5 (vessel wall); 10.5 +/- 4.4 (blood); 14.3 +/- 5.2 (fat); and 45.6 +/- 18.0 (myocardium). No problems occurred with ECG-gating or power deposition (SAR) limits.

Adult↗

Fetal sheep brains: findings at functional blood oxygen level-dependent 3-T MR imaging--relationship to maternal oxygen saturation during hypoxia.

PURPOSE: To quantify the dependence of the signal intensity (SI) at blood oxygen level-dependent (BOLD) magnetic resonance (MR) imaging of fetal sheep brains on maternal oxygen saturation and to investigate the influence of positions of regions of interest (ROIs). MATERIALS AND METHODS: All experimental protocols were reviewed and approved by the local authorities on animal protection. The brains of singleton fetuses of five anesthetized sheep were subjected to rapid sequences (single-shot echo-planar imaging) of BOLD measurements with a 3-T MR imaging unit. Maternal oxygen saturation and heart rate were recorded continuously. After a normoxic phase, hypoxia was induced by reducing the oxygen in a ventilated gas mixture. ROIs were placed in the cerebrum at a reference level and in the cerebellum. Normalized BOLD SI values were calculated from the mean values of steady-state BOLD SIs at the control (SI(c)) and hypoxic (SI(h)) plateaus as follows: normalized BOLD SI = (SI(h)/ SI(c)) x 100. Normalized BOLD SI values were correlated with maternal oxygen saturation, and linear regression (slope) analysis was performed. Additionally, ROIs were varied in section level and position. Differences in normalized BOLD SI values for ROI placements were calculated by using analysis of variance. A t test was performed to evaluate differences. RESULTS: Mean maternal oxygen saturation (as the percentage of oxygen in the blood) was 88% (95% confidence interval [CI]: 80%, 96%) in the control period. During hypoxia, it was reduced to 62% (95% CI: 50%, 75%), while fetal normalized BOLD SI decreased to 64% (95% CI: 44%, 85%) in the cerebrum and 56% (95% CI: 32%, 80%) in the cerebellum. Correlations between normalized BOLD SI values and maternal oxygen saturation were as follows: r2 = 0.84 and slope = 1.27 (95% CI: 1.17, 1.36) in the cerebrum and r2 = 0.83 and slope = 1.54 (95% CI: 1.44, 1.63) in the cerebellum. Normalized BOLD SI was 4% lower in the section above the reference level. Variations in normalized BOLD SI for different ROI positions ranged between 0% and 12%. CONCLUSION: The depletion of oxygen supply is reflected by decreases in fetal brain BOLD SIs that are more distinct in the cerebellum than in the cerebrum. Normalized BOLD SI is influenced only slightly by ROI position.

Analysis of Variance↗

Method for spatially interleaving two images to halve EPI readout times: two reduced acquisitions interleaved (TRAIL).

A new MRI method is presented that can generate images using half the normal readout time or, more usefully, half the number of phase-encode steps, combining two readouts per excitation. However, the corresponding data are interleaved in image space-not in k-space, as in many other fast techniques. This gives a resilience to the phase-related artifacts that can occur in many other techniques due to subject motion. A modified stimulated-echo experiment is used to create two low-resolution images from a single sequence. The magnetization that contributes to these images is nonuniformly distributed within each pixel, forming two sinusoidal waves in quadrature, with an oscillation period of exactly two pixels. Since only half of each pixel contributes significant signal, the two images can be interleaved to create a full image with twice as many pixels and double the resolution. When the technique is used in the phase-encode direction, the effective imaging time is halved, though with two readouts per TR period. When two half-length echo-planar readouts are used, the method can also reduce blurring and distortion by halving the effective readout time for echo-planar imaging (EPI). For even further improvements, the technique can be combined with partial Fourier or parallel imaging.

Echo-Planar Imaging↗