Undersampled elliptical centric view-order for improved spatial resolution in contrast-enhanced MR angiography.

Although contrast-enhanced MR angiography (CE-MRA) has been successfully developed into a routine clinical imaging technique, there is still need for improved spatial resolution in a given acquisition time. Undersampled projection reconstruction (PR) techniques maintain spatial resolution with reduced scan times, and the elliptical centric (EC) view order provides high quality arterial phase images without venous contamination. In this work, we present a hybrid elliptical centric-projection reconstruction (EC-PR) technique to provide spatial resolution improvement over standard EC in a given time. The k-space sampling was performed by undersampling the periphery of the k(Y)-k(Z) phase encoding plane of an EC view order in a PR like manner. The sampled views were maintained on a rectilinear grid, and thus reconstructed by standard 3DFT. The non-sampled views were compensated either by zero-filling or performing a 2D homodyne reconstruction. Compared to a fully sampled k-space, the EC-PR sequence acquired in the same scan time provides a resolution improvement of about two, as shown by point spread function analysis and phantom experiments. The hypothesis that EC-PR provides improved resolution while retaining diagnostically adequate SNR was tested in 11 CE-MRA studies of the popliteal and carotid arteries and shown to be true (P < 0.03).

Carotid Arteries↗

Improved spectral selectivity and reduced susceptibility in SSFP using a near zero TE undersampled three-dimensional PR sequence.

PURPOSE: To improve the performance of fat/water separation and reduce the sensitivity to susceptibility variation in balanced SSFP sequences. MATERIALS AND METHODS: Decreasing the repetition time (TR) reduces susceptibility artifacts in SSFP imaging. A shorter TR may also improve the spectral selectivity obtained when linearly combining data acquired using different radiofrequency phase cycling schedules. The desired short TR is achieved by using an angularly undersampled three-dimensional radial acquisition sequence that achieves a near zero echo time (TE) and also a short TR. RESULTS: Images from human volunteers demonstrate broad coverage of the cervical spine and knee with isotropic resolution. Excellent fat/water separation is achieved in these studies. CONCLUSION: The short TR capability of the proposed sequence greatly improves the fat suppression in SSFP imaging. High-resolution volumetric T2-like contrast imaged with reduced susceptibility artifacts can be obtained from a single acquisition using this technique.

Cartilage, Articular↗

Time-resolved contrast-enhanced imaging with isotropic resolution and broad coverage using an undersampled 3D projection trajectory.

Time-resolved contrast-enhanced 3D MR angiography (MRA) methods have gained in popularity but are still limited by the tradeoff between spatial and temporal resolution. A method is presented that greatly reduces this tradeoff by employing undersampled 3D projection reconstruction trajectories. The variable density k-space sampling intrinsic to this sequence is combined with temporal k-space interpolation to provide time frames as short as 4 s. This time resolution reduces the need for exact contrast timing while also providing dynamic information. Spatial resolution is determined primarily by the projection readout resolution and is thus isotropic across the FOV, which is also isotropic. Although undersampling the outer regions of k-space introduces aliased energy into the image, which may compromise resolution, this is not a limiting factor in high-contrast applications such as MRA. Results from phantom and volunteer studies are presented demonstrating isotropic resolution, broad coverage with an isotropic field of view (FOV), minimal projection reconstruction artifacts, and temporal information. In one application, a single breath-hold exam covering the entire pulmonary vasculature generates high-resolution, isotropic imaging volumes depicting the bolus passage.

Abdomen↗