PubMed Health⌕ Search

Biomedical subjects

Andrew W Lloyd

Publications and source records attributed to Andrew W Lloyd.

16 recordsLinked to original sources

Mesoporous carbide-derived carbon with porosity tuned for efficient adsorption of cytokines.

Porous carbons can be used for the purification of various bio-fluids, including the cleansing blood of inflammatory mediators in conditions such as sepsis or auto-immune diseases. Here we show that the control of pore size in carbons is a key factor to achieving efficient removal of cytokines. In particular, the surface area accessible by the protein governs the rate and effectiveness of the adsorption process. We demonstrate that novel mesoporous carbon materials synthesized from ternary MAX-phase carbides can be optimized for efficient adsorption of large inflammatory proteins. The synthesized carbons, having tunable pore size with a large volume of slit-shaped mesopores, outperformed all other materials or methods in terms of efficiency of TNF-alpha removal and the results are comparable only with highly specific antibody-antigen interactions.

Adsorption↗

The in vitro adsorption of cytokines by polymer-pyrolysed carbon.

This study investigated a range of phenol-formaldehyde-aniline-based pyrolysed carbon matrices and their component materials, for their ability to adsorb a range of inflammatory cytokines crucial to the progression of sepsis. The efficiency of adsorption of the target molecules from human plasma was assessed and compared to that of Adsorba 300C, a commercially available cellulose-coated activated charcoal. Results indicate that a number of the primary carbon/resin materials demonstrate efficient adsorption of the cytokines studied here (TNF, IL-6 and IL-8), comparable to other adsorbents under clinical investigation. Our findings also illustrate that these adsorbent capabilities are retained when the primary particles are combined to form a pyrolysed carbon matrix. This capability will enable the engineering of the carbon matrix porosity allowing a blend of carbonised particle combinations to be tailored for maximum adsorption of inflammatory cytokines. The present findings support further investigation of this carbon material as a combined carbon-based filtration/adsorbent device for direct blood purification.

Adsorption↗

Calcium-binding phospholipids as a coating material for implant osteointegration.

Among the many biomolecules involved in the bone mineralization processes, anionic phospholipids play an important role because of their ability to bind calcium. In particular, phosphatidylserine is a natural component of the plasmalemma and of the matrix vesicles generated from the osteoblast membrane to create nucleation centres for calcium phosphate crystal precipitation. In the present work, we demonstrate that calcium-binding phospholipids can be used as biomimetic coating materials for improving the osteointegration of metal implants. Relatively thick phosphatidylserine-based coatings were deposited on titanium coupons by dip-coating. Upon dehydration in a simulated body fluid phospholipids were quickly crosslinked by calcium and re-arranged into a three-dimensional matrix able to induce rapid formation of a calcium phosphate mineral phase. The rate of mineralization was shown to be dependent on the adopted coating formulation. In the attempt to closely mimic the cell membrane composition, heterogeneous formulations based on the mixing of anionic phospholipids (either phosphatidylserine or phosphatidylinositol) with phosphatidylcholine and cholesterol were synthesized. However, surface plasmon resonance studies as well as scanning electron microscopy and elemental analysis demonstrated that the homogeneous phosphatidylserine coating was a more effective calcification environment than the heterogeneous formulations.

Biomimetic Materials↗

DC bead: in vitro characterization of a drug-delivery device for transarterial chemoembolization.

PURPOSE: The purpose of this investigation is to present the in vitro characterization and detailed drug-loading procedure for DC Bead, a microsphere product that can be loaded with chemotherapeutic agents for embolization. MATERIALS AND METHODS: DC Bead is an embolic microsphere product that is capable of being loaded with anthracycline drugs such as doxorubicin just before administration in a transarterial chemoembolization (TACE) procedure. Beads can be loaded from solutions prepared from doxorubicin powder or the doxorubicin HCl formulation. In this evaluation, bead sizes were measured by optical microscopy with video imaging. Gravimetric analysis demonstrated the effect of drug loading on bead water content, and its consequent impact on bead compressibility was determined. The subsequent deliverability of the beads was assessed by mixing the beads with contrast medium and saline solution and passing the beads through an appropriately sized microcatheter. A T-cell apparatus was used to monitor the in vitro elution of the drug from the beads over a period of 24 hours in various elution media. RESULTS: DC Bead spheres could be easily loaded with doxorubicin to a recommended level of 25 mg/mL of hydrated beads by immersion of the beads in the drug solution for 10-120 minutes depending on microsphere size. Other commercial embolic microspheres were shown not to load doxorubicin to the same extent or release it in the same fashion and were considered unsuitable for local drug delivery. Maximum theoretic capacity for DC Bead was approximately 45 mg/mL. Increase in doxorubicin loading resulted in a concomitant decrease in water content and consequential increase in bead resistance to compression force. Drug loading also resulted in a decrease in the average size of the beads, which was dependent on bead size and drug dose. This did not impact bead delivery at any drug loading level to a maximum of 37.5 mg/mL. Beads 100-700 microm in size could be delivered through 2.7-F microcatheters, whereas the 700-900-microm range required 3-F catheters. Modeling of the kinetics of drug elution from the beads in vitro at a loading dose of 25 mg/mL yielded calculated half-lives of 150 hours for the 100-300-microm range to a maximum of 1,730 hours for the 700-900-microm size range, which was dependent on the ionic strength of the elution medium. For comparison, there was a rapid loss of drug from an unstable Lipiodol emulsion with a half-life of approximately 1 hour. CONCLUSIONS: DC Bead can be loaded with doxorubicin to provide an accurate dosage of drug per unit volume of beads. Drug elution is dependent on ion exchange with the surrounding environment and is controlled and sustained, unlike the rapid separation of the drug from Lipiodol. Drug loading has no impact on the handling and deliverability of the beads, making them suitable for superselective TACE.

Antibiotics, Antineoplastic↗

Novel biocompatible phosphorylcholine-based self-assembled nanoparticles for drug delivery.

Major challenges associated with nano-sized drug delivery systems include removal from systemic circulation by phagocytic cells and controlling appropriate drug release at target sites. 2-methacryloyloxyethyl phosphorylcholine (MPC) has been copolymerised in turn with two pH responsive comonomers (2-(diethylamino)ethyl methacrylate (DEA) and 2-(diisopropylamino)ethyl methacrylate (DPA), to develop novel biocompatible drug delivery vehicles. Micelles were prepared from a series of copolymers with varying block compositions and their colloidal stability and dimensions were assessed over a range of solution pH using photon correlation spectroscopy. The drug loading capacities of these micelles were evaluated using Orange OT dye as a model compound. The cytotoxicity of the micelles was assessed using an in vitro assay. The MPC-DEA diblock copolymers formed micelles at around pH 8 and longer DEA block lengths allowed higher drug loadings. However, these micelles were not stable at physiological pH. In contrast, MPC-DPA diblock copolymers formed micelles of circa 30 nm diameter at physiological pH. In vitro assays indicated that these MPC-DPA diblock copolymers had negligible cytotoxicities. Thus novel non-toxic biocompatible micelles of appropriate size and good colloidal stability with pH-modulated drug uptake and release can be readily produced using MPC-DPA diblock copolymers.

Biocompatible Materials↗

Assessing the in vitro biocompatibility of a novel carbon device for the treatment of sepsis.

The aim of the present study was to conduct a preliminary investigation into the blood biocompatibility of a novel, uncoated carbon for use in a filtration/adsorption device for the treatment of sepsis. Carbon well prototypes were manufactured from phenol-formaldehyde-aniline-based pyrolysed carbons using monolithic polymer technology. Inflammatory blood cell and plasma protein mediation of the inflammatory response were evaluated using the novel carbon prototypes and compared with dialyser membrane and tissue culture plate controls. Assays determining monocyte and granulocyte adhesion, platelet adhesion and activation, granulocyte activation and complement activation were performed. Preliminary findings suggest an adsorptive but passivating carbon surface. Moderate levels of monocyte and granulocytes adhesion were seen in conjunction with adsorption of plasma proteins to the carbon surface. Activation of granulocyte and adherent platelets was not detected and the complement cascade was not activated by the carbons, indicating a surface compatible with blood contact. The results support the further development of the proposed carbon-based device for the treatment of sepsis.

Biocompatible Materials↗

Effects of phosphatidylserine coatings on titanium on inflammatory cells and cell-induced mineralisation in vitro.

Ideally an active bone biomaterial should increase the mineralisation rate at the bone healing sites, keeping at the same time the inflammation process to levels required for tissue regeneration. Our studies suggest that in addition to improving the nucleation process for new bone formation, coating titanium with phospholipids may reduce the inflammatory response, which was shown to vary depending on the formulation employed. As phosphatidylserine reduced the inflammatory response to the greatest extent, in the second part of this study we examined its effect on osteoblast mineralisation. These studies demonstrated that phosphatidylserine improves the nucleation process for bone formation, by promoting the formation of bone-like tissue, so the high mineralisation potential of phosphatidylserine-coated titanium, together with the lower level of inflammatory response, supports the further development of this technology for coating osteointegrative devices.

Biocompatible Materials↗

The effect of phosphorylcholine-coated materials on the inflammatory response and fibrous capsule formation: in vitro and in vivo observations.

Several experiments were performed to compare the in vitro adhesion of human macrophage and granulocyte inflammatory cells to polyethylene terephthalate substrate and the same coated with a phosphorylcholine (PC)-based polymer. The inclusion of various types of serum at different stages in the assay indicated that protein adsorption and passivation of the surface may be responsible for reducing the number of inflammatory cells adhering to the uncoated polyethylene terephthalate controls. In all of the assays performed there was a statistically significant reduction (p < 0.05; analysis of variance) of the number of inflammatory cells adhering to the PC-coated samples, linked to the ability of these surfaces to resist protein adhesion. Implantations of PC-coated stainless steel and high-density polyethylene USP control samples were made in a rabbit intramuscular model. Histological examination of the number of inflammatory cells present around the implant sites 4 weeks postimplantation showed there were 40% less cells associated with the PC-coated samples compared with control, but this was not statistically significant. Fibrous capsule thickness, however, whereas marginally less at 4 weeks, had almost completely regressed for the PC-coated sample at 13 weeks postimplantation and was statistically thinner (p < 0.01; Mann-Whitney U test) than the high-density polyethylene USP control. These findings support the view that low biointeractions observed for PC-based technology in vitro can result in reduced inflammation and foreign body reaction in vivo.

Capsules↗

Biological evaluation and drug delivery application of cationically modified phospholipid polymers.

Phospholipid-like polymers based on 2-methacryloyloxyethyl phosphorylcholine containing varying amounts of the cationically charged monomer choline methacrylate (CMA) from 0 to 30 wt% have been prepared. Substrates coated with these materials were shown to bind significantly lower amounts of specific proteins compared to the uncoated control. ELISA assays demonstrated that fibrinogen did not bind appreciably to coatings containing 0-30% CMA, whereas albumin binding was seen to increase significantly as the CMA content of the coating increased. Platelet activation assays, measurement of plasma coagulation time and whole blood contact scanning electron micrography demonstrated that the haemocompatibility of the coatings was shown to be unaffected by the CMA component. The CMA polymer coatings have been shown to absorb/adsorb many different drug compounds covering a wide range of molecular weights and release these in a controlled fashion. The range of cationic polymers assessed can interact with the net negative charge found in many large therapeutic biomolecules, such as DNA fragments used in gene therapy, that may be of interest in the preventative treatment of conditions such as restenosis. Coronary stents coated with 6% or 20% CMA-containing polymers have been shown to load and release this type of genetic material irrespective of molecular weight of the biomolecule. Ex vivo and in vivo studies have shown that these compounds can be delivered to the stented section of the vessel with very low quantities delivered outside the vessel target area.

Absorption↗

In vitro host response assessment of biomaterials for cardiovascular stent manufacture.

The deployment of a vascular stent during angioplasty has greatly reduced the risks of restenosis. However, the presence of the device still induces a host response as well as a mechanical action on the blood vessel wall and an alteration of the haemodynamics. Platelet and inflammatory cells can adhere on the stent surface and be activated to produce biochemical signals able to stimulate an excessive proliferation of the smooth muscle cells with the consequent obstruction of the vessel lumen. For these reasons, the host response to two of the materials used in stent manufacture, stainless steel and diamond-like carbon, was investigated in vitro. The data showed that stainless steel induced a higher level of host response both in terms of platelet aggregation and macrophage activation. However, the spreading of inflammatory cells was more accentuated on diamond-like carbon. The inflammatory cells produced levels of platelet-derived growth factor, a key signal in smooth muscle cell proliferation, similar to stainless steel thus suggesting that carbon coatings may not be able to prevent restenosis.

Adsorption↗

Fibrinogen adsorption and platelet adhesion to metal and carbon coatings.

In order to study the haemocompatibility of metal and carbon coatings, fibrinogen adsorption and platelet adhesion to various coatings have been investigated. Two metallic coatings--titanium and zirconium, and two carbon coatings - isotropic diamond-like and isotropic graphite-like coatings, were prepared by plasma vapour deposition onto stainless steel substrate. It has been shown that the adsorption of fibrinogen to metal and carbon coatings and its post-adsorptive transition are dependent on both the material properties and the fibrinogen environment. The adsorption of fibrinogen from human plasma on titanium and zirconium coatings is similar to that on uncoated stainless steel surface. Both carbon coatings adsorb much greater amount of fibrinogen from plasma, and fibrinogen retention by carbon surfaces is also greater than by metal surfaces. Increased numbers of adhered platelets have been found on both carbon coatings in comparison to the metal materials, although this does not correlate with the amount of adsorbed fibrinogen.

Adsorption↗

Developments in microarray technologies.

The focus of high-throughput drug discovery has progressed through the genome and the transcriptome and is now moving towards more difficult problems in assessing the proteome, glycome and metabolome. Microarrays are currently the major tool in the assessment of gene expression via cDNA or RNA analysis; however, they are also used to screen libraries of proteins and small molecules. Microarrays have helped to extract more information from smaller sample volumes and enabled the incorporation of low-cost high-throughput assays in the drug discovery process. The technology continues to develop and is being rapidly transferred into more challenging areas, with the potential to further aid and enhance the drug discovery process through the development of, for example, proteomic, glycomic and tissue arrays.

Gene Expression Profiling↗

The biocompatibility of crosslinkable copolymer coatings containing sulfobetaines and phosphobetaines.

The comparison of copolymers containing sulfobetaine or phosphobetaine moieties for use as potential biocompatible coatings has been investigated. Two statistical copolymers were produced by a free radical polymerisation technique, one based on a sulfobetaine and the other on a phosphobetaine, both with a silyl group component to allow thermal crosslinking after coating. PMMA and glass discs were dip-coated with the polymers and their properties were compared to the uncoated controls. Bacterial adhesion to these coated materials was assessed using Staphylococcus epidermidis, Staphylococcus aureus and Pseudomonas aeruginosa. Human macrophages and granulocytes were used to assess the adhesion and activation of inflammatory cells whilst mouse 3T3 fibroblast cells were used to assess the propensity for the materials to support fibroblast cell adhesion. In all cases the polymer coatings reduced cell adhesion with respect to the base materials. The phosphobetaine-based copolymer coatings were shown to be markedly superior to the sulfobetaine-based copolymer coatings.

3T3 Cells↗

Synthesis and characterization of biocompatible thermo-responsive gelators based on ABA triblock copolymers.

The synthesis of biocompatible, thermo-responsive ABA triblock copolymers in which the outer A blocks comprise poly(N-isopropylacrylamide) and the central B block is poly(2-methacryloyloxyethyl phosphorylcholine) is achieved using atom transfer radical polymerization with a commercially available bifunctional initiator. These novel triblock copolymers are water-soluble in dilute aqueous solution at 20 degrees C and pH 7.4 but form free-standing physical gels at 37 degrees C due to hydrophobic interactions between the poly(N-isopropylacrylamide) blocks. This gelation is reversible, and the gels are believed to contain nanosized micellar domains; this suggests possible applications in drug delivery and tissue engineering.

Acrylic Resins↗

Interfacial bioengineering to enhance surface biocompatibility.

This article reviews recent developments in interfacial bioengineering to improve the biocompatibility of implanted materials. It includes a discussion of biomimetic approaches to bioinert and bioactive surface coatings to improve the in vivo performance of existing medical devices.

Biocompatible Materials↗