Momentum-weighted conjugate gradient descent algorithm for gradient coil optimization.

MRI gradient coil design is a type of nonlinear constrained optimization. A practical problem in transverse gradient coil design using the conjugate gradient descent (CGD) method is that wire elements move at different rates along orthogonal directions (r, phi, z), and tend to cross, breaking the constraints. A momentum-weighted conjugate gradient descent (MW-CGD) method is presented to overcome this problem. This method takes advantage of the efficiency of the CGD method combined with momentum weighting, which is also an intrinsic property of the Levenberg-Marquardt algorithm, to adjust step sizes along the three orthogonal directions. A water-cooled, 12.8 cm inner diameter, three axis torque-balanced gradient coil for rat imaging was developed based on this method, with an efficiency of 2.13, 2.08, and 4.12 mT.m(-1).A(-1) along X, Y, and Z, respectively. Experimental data demonstrate that this method can improve efficiency by 40% and field uniformity by 27%. This method has also been applied to the design of a gradient coil for the human brain, employing remote current return paths. The benefits of this design include improved gradient field uniformity and efficiency, with a shorter length than gradient coil designs using coaxial return paths.

Algorithms↗

Single-shot magnetic field mapping embedded in echo-planar time-course imaging.

A technique for acquiring magnetic field maps simultaneously with gradient-recalled echo-planar time-course data is described. This technique uses a trajectory in which the central part of k-space is collected twice. For a 64 x 64 image acquired with a 125-kHz bandwidth, a field map suitable for geometric correction can be collected simultaneously with the echo-planar time-course data in <70 ms. The field maps generated by this technique are registered with the magnitude images because they are calculated using the same data. They do not suffer from errors due to subject motion, or from different geometric distortions that can result from using different pulse sequences. In addition to correcting geometric distortions that resulted from dynamic magnetic field perturbations, this method was used to measure field shifts arising from respiration and jaw motion across five subjects. Values ranged from 0.035 to 0.165 parts per million (ppm).

Brain↗

Multishot partial-k-space EPI for high-resolution fMRI demonstrated in a rat whisker barrel stimulation model at 3T.

A multishot partial-k-space EPI technique is presented and validated by fMRI at high spatial resolution. High-resolution phase maps corrected by phase-encoded reference scans have less off-resonance effects. Phantom studies demonstrate that this method can substantially improve partial-k-space EPI image formation. BOLD fMRI at submillimeter spatial resolution (156 x 156 x 2000 microm(3), 0.049 microl) was achieved in a rat whisker barrel stimulation model using this technique. The study included eight rats, five of which were administered an intravascular contrast agent (monocrystalline iron oxide nanocolloid (MION)) after the BOLD experiments. In two rats the highest BOLD responses were in the deep layers (IV-VI), and in six rats the highest responses were on the surface and in the deep cortical layers. Most of the pixels that exhibited high BOLD responses had high blood volume weightings. The benefits of this technique are expected to increase for high-resolution fMRI at higher magnetic fields, where T(2) (*) is shorter.

Animals↗